Huba Pressure sensor 680
The pressure transmitters of type 680 with piezoresistive measuring elements have compensated, adjusted and amplified sensor signals which are available as standard voltage or current outputs. The transmitter housing is available with various pressure and electrical connections. Manufactured from stainless steel, its welded construction provides a watertight seal. With its sophisticated building block system, individual designs to meet specific applications are possible.
Effective overload protection due to chemically eteched chip diaphragm and
specially designed glass gland
Fast and affordable customer specific solutions due to building block system, even for small quantities
Compact construction with SMD technology enhances operational reliability in the presence of shock and vibration
Welded construction provides 100% sealing against media
Relative and absolute 0 ... 25 bar
Overpressure > 25 ... 1000 bar
Overload
At Pressure ranges 0.1 ... 2 bar 3x pressure range, min. 3 bar
At Pressure ranges > 2 ... 600 bar 3x pressure range, max. 850 bar
At Pressure ranges > 600 ... 1000 bar 1500 bar
Rupture pressure
At Pressure ranges 0.1 ... 2 bar > 200 bar
At Pressure ranges > 2 ... 600 bar > 850 bar
At Pressure ranges > 600 ... 1000 bar > 1500 bar
Medium
Permissible medium liquids and gases
Material
Pressure connection, diaphragm, case stainless steel 1.4435 (316L) (Titanium or Hastelloy C on request)
Sealing material FPM (other on request)
Temperature
2)
Medium temperature -40 ... +150 ÀC
Ambient temperature -40 ... +125 ÀC
Storage temperature -40 ... +125 ÀC
Output and power supply
3) 4)
output power supply permissible load
5)
3-wire
0 ... 5 V 12 ... 30 VDC > 10 kOhm
0 ... 10 V 12 ... 30 VDC > 10 kOhm
2-wire 4 ... 20 mA 9 ... 33 VDC
supply voltage - 9V
[Ohm] max.
2-wire (Ex) 4 ... 20 mA 9 ... 28 VDC
supply voltage - 9V
[Ohm] max.
Ex-Version gas dust
Ex-Admission (Depending on execution, see valid ATEX certificate) II 1G Ex ia IIB/IIC T3 ... T6 II 1D Ex iaD 20 IP6x T145 ... T70 ÀC
Standards EN 60079-0 / EN 60079-11 EN 61241-0 / EN 61241-11
Temperature class Ex-Version T6 T4 T3
Ambient temperature Ta -40 ... +50 ÀC -40 ... +85 ÀC -40 ... +125 ÀC
Medium temperature -40 ... +50 ÀC -40 ... +110 ÀC -40 ... +150 ÀC
Electrical connection
Cable PUR, PE or Teflon in variable lengths
6)
Connector
7)
DIN EN 175301-803-A / Lumberg RSF 4 / RSF 50 / Binder 723
Pressure connection
Inside thread G ¼ 1)
Outside thread G ¼, G ½ 1)
Tests / Admissions norm character level
Mechanical load
EN 60068-2-6 vibration 10 g (4 ... 2000 Hz, oscillation μ 10 mmpp)
EN 60068-2-27 shock 100 g (pulse duration 6 ms)
Interference emit EN 55022 emitted interference, class B < 30 dBøV/m (0.03 ... 1 GHz)
Interference resistance
EN 61000-4-2 discharge static electricity 8 kV contact-, 15 kV air discharge
EN 61000-4-3 electromagnetic radiation 10 V/m, 0.08 ... 2.7 GHz, 80% AM 1 kHz, 3s
EN 61000-4-4 fast transients (burst) 4 kV
EN 61000-4-5
impulse voltage (surge)
Line-Line 0.5 kV/42 Ohm,
Line-Earth 1 kV/42 Ohm
EN 61000-4-6 grid-bound electromagnetic blockage 10 V, 0.15 ... 80 MHz, 80% AM 1 kHz, 3s
Packaging
Single packaging carton padded cellular material
Weight
Cable version (2 m) ~ 250 g
Connector version ~ 150 g
Write a review
Your Name:Your Review: Note: HTML is not translated!
Rating: Bad Good
Enter the code in the box below: