Huba Pressure sensor 515
These compact OEM pressure transmitters type 515 meet the high est specification for mechanical stress, EMC compatibility, and operational reliability.
This sensor utilises a ceramic technology, developed by Huba Control and for the last 10 years, in millions of applications. Used in combination with unique integrated electronic design, means that the type 515 series has a high degree of accu racy for all temperature ranges. These units are available in small or production quantities, with an excellent price to performance ratio.
Compact, rugged construction for highest operational reliability
Negligible temperature influence on accuracy
Excellent EMC capacity
Technical overview
Pressure range
Relative -1 ... 0 ă 600 bar
Absolute 0 ... 25 bar
Operating conditions
Medium Liquids
Temperature
FPM -15 ... +125 ÀC
EPDM -25 ... +125 ÀC
NBR -25 ... +85 ÀC
FPM spec. -40 ... +150 ÀC
Ambient max. +85 ÀC
Tolerable overload / repture pressure
1)
-1 ... 4 bar 3.0 x fs
6 ... 600 bar 2.5 x fs (max. 900 bar)
Materials
Case Stainless steel 1.4305 / AISI 303
Materials in contact with the medium
Pressure connection Stainless steel 1.4305 / AISI 303
Sensor Ceramic Al2O3 (96%)
Media stop sytsem PPS
Sealing material FPM, EPDM, NBR, FPM spec.
Media stop system
Patented media stop system to prevent media egress when exeeding rupture pressure range (> 40 bar nominal value).
Electrical overview
Output Power supply Load Current consumption
2)
2 wire 4 ... 20 mA 8.0 ... 33 VDC <
supply voltage - 8 V
[Ohm] < 20 mA
3 wire
0 ... 5 V 8.0 ... 33 VDC >10 kOhm / < 100 nF < 4 mA
1 ... 6 V 8.0 ... 33 VDC >10 kOhm / < 100 nF < 4 mA
0 ... 10 V 11.4 ... 33 VDC >10 kOhm / < 100 nF < 4 mA
0 ... 10 V 24 VAC μ15% >10 kOhm / < 100 nF < 4 mA
ratiom. 10 ... 90% 5 VDC μ5% >10 kOhm / < 100 nF < 4 mA
Polarity reversal protection Short circuit proof and protected against polarity reversal. Each connection is protected against crossover up to max. supply voltage.
Insulation voltage
standard 500 VDC
optional 1000 VDC
Dynamic response
Response time < 2 ms, typ. 1 ms
Load cycle < 100 Hz
Protection standard
IP 69K
Electrical connection
Cable PUR 1.5 m
Pressure connection
Inside thread G ¼ with O-Ring seal
Outside thread
G ¼ sealed at back, DIN 3852 form E
G ½ sealed at front
G ½ sealed at back and manometer (combi)
¼ -18 NPT
R ¼, DIN 2999
M12x1.5, sealed at back, DIN 3852 form E
M14x1.5, sealed at back, DIN 3852 form E
Installation arrangement
Unrestricted
Tests / Admissions
Electromagnetic compatibility CE conformity acc. EN 61326-2-3
Shock acc. IEC 60068-2-27 40 g, 6 ms half sine wave, all 3 directions. Free fall from 2 m on concrete (6x)
Constant shock acc. IEC 60068-2-29 40 g for 6 ms, 1000 x all 3 directions
Vibration acc. IEC 60068-2-6 25 g, 2 ... 2000 Hz with amplitude μ 15 mm, 1 Octave/min. all 3 directions, 50 constant load
Weight
With thread G ½ ~ 225 g
All other versions ~ 180 g