Fischer pressure transmitter Building technology Differential Pressure Transmitter DE16
Application
Measuring transmitter for overpressure, partial vacuum and differential pressure. This series is suitable for various measuring applications in the field of in-
dustrial and sanitary techniques.
Typical applications:
Measurement of differential pres-sure between forward- and return-flow in heating systems. Monitoring of filters, blowers and compressors.
Main Features
Overpressure protection, Rugged design. Maintenance and wear free inductive pick-up Multiple applications.
Specifications
General
Measuring range0...60 mbar to 0....25 bar (acc. to Ordering Code)
Nominal pressure25 bar
Max. pressure loadone-sided overpressure protected up to nominal pressure,
on (+) and (-) side of diaphragm, partial vacuum protected
Perm. ambient temperature-10!aC..... +70!
Perm. medium temperature70!a
Protection classIP 54 per DIN EN 60529
Mounting positionany direction
Linearity< 2% FS
Hysteresis< 1% FS
Electrical 2-wire connection with or without LC-Display 3-wire connection
3-wire connection with LC-Display without LC-Display
Electrical connection2-wire3-wire3-wire3-wire
3-wire
Supply voltage24 V DC24 V AC/DC24 V AC/DC24 V AC/DC
24 V AC/DC
Perm. supply voltage15...30V DC15...30V DC 15...30V DC 18...30V DC
15...30V DC
20...28V AC 20...28V AC 21...27V AC
21...27V AC
Power consumption 1 W 0.5 W 1 W 2 W 2 W
Output signal4-20 mA0-10 V DC0-20 mA 0-10 V DC
0-20 mA
4-20 mA
4-20 mA
Load in case of nominal voltagemax. 600 > 1 K max. 900 > 1 K
max.380
Current limitmax. 23 mAmax. 10 mAmax. 25 mAmax. 15 mA
max. 30 mA
Voltage limit---approx. 12 V DC---approx.11.5V DC
---
Zero point adjustmentapprox. 10% FS
Slope adjustmentapprox. 10% FS
Measuring Indication 3-digit LC-Display
Electrical connection numbered cable,
prewired cable terminal box, plug acc. to DIN EN 175 301-803-A
Pressure connection female thread G, cutting ring connection for 6, 8, 10, 12 mm tube of brass,
zinced steel or stainless steel, connection shank G DIN EN 837
Measuring System
Measuring range 10 bardiaphragm measuring system, diaphragms of reinforced elastomere
Measuring range 16
barcapsule element measuring system, capsule element of DURATHERM
Materials
Pressure chamberaluminium Gk Al Si 12 (Cu), varnished black
aluminium Gk Al Si 12 (Cu) HART-COAT
stainless steel 1.4305
Measuring diaphragm
diaphragm and gaskets of NBR or Viton
capsule element of DURATHERM Ni Cr Co-alloy
Materials, mediastainless steel 1.4310, 1.4305
Materials, housingmakrolon
Weightpressure chamber Al = 1.2 kg, pressure chamber 1.4305 = 3.5 kg
Mounting pipe mounting, pressure connections acc. to symbols
- by screwed in cutting ring or clamping ring connection
- by screwed on connection shank acc. to DIN EN 837
wall mounting - 3 fastening elements
Write a review
Your Name:Your Review: Note: HTML is not translated!
Rating: Bad Good
Enter the code in the box below: