Dwyer pressure transmitter series 672 Low Pressure Transducer
The Series 672 Low Pressure Transducer is a perfect solution to any application where a very accurate low pressure transducer is necessary. Using
variable capacitance technology, the Series 672 is designed to measure pres-sures as low as 10 w.c. up to 400 w.c., very low ranges for a single connection
pressure transducer. The 672 also features a 0.25% F.S. accuracy. Use the Series 672 in liquid level, flood warning, waste water, clean room, and open
channel flow applications.
SPECIFICATIONS
Service: Compatible liquids and gases.
Wetted Materials: 318 Duplex SS, Ceramic, Fluoroelastomer (FKM).
Housing Material: 318 Stainless Steel.
Accuracy: 0.25% F.S. (RSS). Includes non-linearity, hysteresis, an
non-repeatability.
Stability: 0.25% F.S./1 year.
Temperature Limits: -40 to 212F (-40 to 100C
Compensated Temperature Limits: -5 to 140F (-20 to 60C
Pressure Limits: 29 PSI (2 bar) for up to 85? w.c. (0.2 bar) ranges; 58
PSI (4 bar) for 85? to 140? w.c. (0.2 to 0.35 bar); 73 PSI (5 bar) for 141?
to 400? w.c. (0.35 to 1 bar).
Thermal Effects:
Zero: 1.0%F.S./100F (2.0%F.S./100C).
Span: 1.0%F.S./100F (2.0%F.S./100C).
Power Requirements:
4-20 mA: 9-35 VDC
0-5 VDC: 7.5-35 VDC
Output Signal: 4-20 mA (2-wire) or 0-5 VDC (3-wire).
Zero & Span Adjustment: 10% F.S. each (by Potentiometer)
Response Time: 5 ms.
Max Loop Resistance: 1.325 k
Electrical Connections: Large DIN 43650 connector with mating plug.
Process Connection: 1/4±-18 NPT male
Enclosure Rating: NEMA 4X (IP65).
Weight: 11.6 oz (330 g).
Agency Approval: CE.
Model | Description |
Low pressure transducer, 0-10" w.c., 0-5 VDC output. | |
Low pressure transducer, 0-10" w.c., 4-20 mA output. | |
Low pressure transducer, 0-15" w.c., 0-5 VDC output. | |
Low pressure transducer, 0-150" w.c., 0-5 VDC output. | |
Low pressure transducer, 0-200" w.c., 0-5 VDC output. | |
Low pressure transducer, 0-25" w.c., 0-5 VDC output. | |
Low pressure transducer, 0-300" w.c., 0-5 VDC output. | |
Low pressure transducer, 0-50" w.c., 0-5 VDC output. | |
Low pressure transducer, 0-400" w.c., 0-5 VDC output. | |
Low pressure transducer, 0-100" w.c., 0-5 VDC output. | |
Low pressure transducer, 0-25" w.c., 4-20 mA output. | |
Low pressure transducer, 0-200" w.c., 4-20 mA output. | |
Low pressure transducer, 0-50" w.c., 4-20 mA output. | |
Low pressure transducer, 0-15" w.c., 4-20 mA output. | |
Low pressure transducer, 0-300" w.c., 4-20 mA output. | |
Low pressure transducer, 0-100" w.c., 4-20 mA output. | |
Low pressure transducer, 0-400" w.c., 4-20 mA output. | |
Low pressure transducer, 0-150" w.c., 4-20 mA output. |