actuator air Cylinder Solenoid Valve Transmitter SMC Parker Festo Schrader Miller Bosch Rexroth CKD Knorr Milwaukee Vickers Taiyo Numatics Mosier Allen Humphrey Koganei
Categories

Rosemount pressure transmitter DP Flow Products Integral Orifice Flowmeters and Primary Elements

3051SFP, 3095MFP, 3051CFP, 2051CFP, 1195

The Rosemount Integral Orifice Flowmeter assembly is designed to meet the need for highly accurate small bore flow measurements with minimal installation and maintenance requirements.

The Rosemount 1195 is suitable for measurement of any clean gas, liquid, or vapor flow. It can be directly mounted to any Rosemount differential pressure transmitter and used in many environments and applications.

  • Available preassembled to the world's most popular pressure transmitters
  • Gasket groove and self-centering orifice plate design to prevent installation errors
  • Numerous process connections and construction material options
  • Wide orifice bore/flow range capability
  • Compliant with NACE MR-0175
Fully Integrated Flowmeter 


Rosemount 3051SFP with Measurement Types 1-4



Rosemount 3051SFP Measurement Type D

Accuracy •Mass flow up to 0.8% of mass flow rate, 14:1 turndown
•Classic MV up to ±0.85 % of flow rate, 8:1 flow turndown
•Volumetric flow up to 0.8% of volumetric flow rate, 14:1 turndown
•Classic MV up to ±0.85% of volumetric flow rate, 8:1 turndown
Repeatability ± 0.1 % ± 0.1 %
Output •4-20mA signal based on HART® Communication 
•WirelessHART with Smart Wireless THUM adapter
•4-20mA signal based on HART® Communication
•WirelessHART 
•FOUNDATION™ fieldbus
Long Term Stability Up to 10-year stability Up to 10-year stability
Warranty Up to 12-year limited warranty Up to 12-year limited warranty
Diagnostics •User-writable process temperature sensor limits
•Sensor Temperature as an output
•Instant Flow Verification
Advanced HART Diagnostic Suite
Line Size ½-in (15 mm)
1-in (25 mm)
1 ½-in (40 mm)
½-in (15 mm)
1-in (25 mm)
1 ½-in (40 mm)
 
Primary Element


1195 Integral Orifice

Service Liquid, Gas, Steam
Accuracy Up to ±0.75% of flow rate
Process Temperature Limits Standard (direct/remote mount):
•  -40 to 450 °F (-40 to 232 °C)
Extended (remote mount only with option code G):
•  -148 to 850 °F (-100 to 454 °C) 
Line Sizes ½-in (15 mm)
1-in (25 mm)
1 ½-in (40 mm)