Rosemount pressure transmitter DP Flow Products Annubar Flowmeters and Primary Elements 3051SFA, 3095MFA, 3051CFA, 2051CFA, 485, 585
Fully Integrated Flowmeter |
|
|
Accuracy | •Mass flow up to 0.8% of mass flow rate, 14:1 turndown •Classic MV up to ±0.85 % of flow rate, 8:1 flow turndown |
•Volumetric flow up to 0.8% of volumetric flow rate, 14:1 turndown •Classic MV up to ±0.85% of volumetric flow rate, 8:1 turndown |
Repeatability | ± 0.1 % | ± 0.1 % |
Output | •4-20mA signal based on HART® Communication •WirelessHART with Smart Wireless THUM adapter |
•4-20mA signal based on HART® Communication •WirelessHART •FOUNDATION™ fieldbus |
Long Term Stability | Up to 10-year stability | Up to 10-year stability |
Warranty | Up to 12-year limited warranty | Up to 12-year limited warranty |
Diagnostics | •User-writable process temperature sensor limits •Sensor Temperature as an output •Instant Flow Verification |
Advanced HART Diagnostic Suite |
Line Size | 2-in. to 8-in. (50 to 200 mm) – Sensor Size 1 6-in. to 36-in. (150 to 900 mm) – Sensor Size 2 12-in. to 72-in. (300 to 1800 mm) – Sensor Size 3 |
2-in. to 8-in. (50 to 200 mm) – Sensor Size 1 6-in. to 36-in. (150 to 900 mm) – Sensor Size 2 12-in. to 72-in. (300 to 1800 mm) – Sensor Size 3 |
Rosemount 485 Annubar Flowmeters |
|
The shape of the APT is fundamental to flow measurement performance. The inventors of APT technology offer the most innovative T-shaped and rugged bi-directional shaped Annubar sensors. These patented primary elements are designed to be resistant to wear, warp and plugging while achieving the highest accuracy and reliability.
|
|
Lower Energy Costs MINIMIZED PERMANENT PRESSURE LOSS Annubar sensors create less blockage in the pipe, leading to a reduction in pumping, compression and fuel costs. |
Reduce Process Variability LOW SIGNAL NOISE Stagnation zones on the backside of the T-shaped Annubar sensor are positioned to reduce noise and measurement inaccuracies that lead to process variations. |
Enhance Measurement at Lower Flows HIGHER SIGNAL STRENGTH The flat upstream surface of the T-shaped Annubar sensor result in a fixed separation point that improves performance over a wider flow range. |
|
Save Installation Time and Cost INTEGRAL THERMOWELL DESIGN Add a temperature measurement without additional pipe penetrations or installation time and expense. The thermowell integral to the 485 Annubar sensor allows maintenance and removal of the RTD without process shutdown. |
Decrease Measurement Error +/- 0.75% of Flow Accuracy The frontal slot design of the sensor measures 70% more of the velocity profile, allowing increased sampling that increases the accuracy of the measurement. |
Rosemount 585 Annubar Flowmeter |
With 40 years of Annubar Emerson designed the 585 Annubar solution with the strength and reliability to withstand the most severe flow applications. |
Reliability in Challenging Applications SOLID SENSOR CONSTRUCTION The solid bar stock design of the 585 Annubar sensor along with the variety of sensor materials available enables maximum strength. |
Simplified Bi-directional Measurement SYMMETRICAL SENSOR DESIGN The Rosemount 585 eliminates the need for two flowmeter assemblies to measure bi-directional flow. Options for dual direct mount transmitters make installation simple and cost effective. |
Write a review
Your Name:Your Review: Note: HTML is not translated!
Rating: Bad Good
Enter the code in the box below: