VU843
The VU843 humidity resistant, Fan Coil Valve Actuators are used in conjunction with VU52, VU53 and VU54 valves for controlling the flow of hot or chilled water in commercial HVAC equipment such as fan coil units, terminal reheat coils and convectors.
Valve Actuator - 24V 50/60hz 2W- 6" Lead
Valve Actuator - 24V 50/60hz 2W- 6" Lead
Valve Actuator - 24V 50/60hz 2W -8" Lead
Two-position actuator for valve bodies with 24V, 50/60Hz
Overview
The VU843 humidity resistant, Fan Coil Valve Actuators are used in conjunction with VU52, VU53 and VU54 valves for controlling the flow of hot or chilled water in commercial HVAC equipment such as fan coil units, terminal reheat coils and convectors.
Features
- Compact construction for easy installation.
- Fits under the cover of most baseboard convectors with actuator fitted to valve body.
- One-button, quick release. Secure 3-point, metal latch to valve body.
- Spring return operation.
- Stainless steel case and aluminum cover. Rust-proof nickel-plated motors available.
- Line or low voltage, rust-resistant motors.
- Manual opener for installation and valve operation on power failure.
- Valve returns to automatic position when power is restored.
- Actuator may be reinstalled or serviced without draining the system or disassembling the valve.
- Slotted conduit hole for faster wiring.
Product Specifications
- Application
- HVAC
- Dimensions (in.)
- 2 3/8 in. high, 3 1/2 in. wide, 2 3/8 in. wide
- Dimensions (mm)
- 62 mm high, 88 mm wide, 60 mm deep
- Used With
- 2-way NC VU valve body (VU53)
- Materials
- Stainless Case, Aluminum Cover
- Comments
- For controlling the flow of hot or chilled water in commercial HVAC equipment such as fan coil units, terminal reheat coils and convectors
- Frequency
- 50 Hz; 60 Hz
- Approvals, Canadian Standards Association
- Certified C/US File No. LR1322
- Electrical Connections
- Leads
- Supply Voltage
- 24V
- Power Consumption
- Driving-- 6 Watts
- Ambient Temperature Range (F)
- 34 F to 125 F ambient at 200 F Fluid
- Ambient Temperature Range (C)
- 1 C to 52 C ambient at 93 C Fluid
- Internal Auxiliary Switch
- 0
- Fluid Temperature (C)
- 94 C
- Fluid Temperature (F)
- 200 F
- Actuator Type
- Valve
- Control Signal
- Two position; SPST
- Fail Safe Mode
- Spring Return
- Stroke (in.)
- 22 deg.
- Timing, Nominal
- Driving @ 60 Hz (sec)-- 15 sec maximum
- Spring Return Timing
- Nominal-- 4 sec
- Maximum Differential Pressure Ratings (Close-off) (psi)
- Depends on Cv rating of valve
- Maximum Differential Pressure Ratings (Close-off) (kPa)
- Depends on Cv rating of valve
- Manual operation
- Lever
- Electrical Connections (in.)
- 6 in.
- Electrical Connections (mm)
- 0.15 m