Buschjost solenoid valve with differential pressure Norgren solenoid valve Series 83030
2/2-way valves DN 15 to DN 50
For neutral gases and liquid fluids
Indirectly solenoid actuated
Diaphragm valves
Flange connection, pressure rating PN 16
Operating pressure 0.1 to 10/16 bar
Description (standard valve)
Solenoid valve for air, water
Switching function: normally closed
Flow direction: determined
Fluid temperature: ¨C10 !aC up to max. +90
Ambient temperature: ¨C10 !aC up to max. +50
Mounting position: optional,
preferably solenoid vertical on top
Material
Body: Cast steel, Brass
Seal seat: NBR
Internal parts: Stainless steel, PVDF resp. Brass from DN 32
For contaminated fluids insertion of a strainer is recommended (see B - accessories).
FeaturesHigh flow rateDamped operationFunctional compact designSolenoid interchangeable without tools (c)Fluids of Group 2 acc. Pressure Equipment Directive 97/23/EC
Symbol
A
Characteristic data
Valves
Part Number Nominal Diameter Operating pressure * k -value **
Weight
v
3
Solenoid with 1 or 2 (mm) min. (bar) max. (bar) (Base m
/h) (kg)
8303200.9101 15 0.1 16 3.8 2.6
8303300.9101 20 0.1 16 6.1 2.8
8303400.9101 25 0.1 16 9.5 3.2
8303500.9101 32 0.1 10 23.0 5.8
8303500.9151 32 0.1 16 23.0 5.9
8303600.9101 40 0.1 10 25.0 6.1
8303600.9151 40 0.1 16 25.0 6.2
8303700.9101 50 0.1 10 41.0 8.4
8303700.9151 50 0.1 16 41.0 8.5
2
* for gases and liquid fluids up to 25 mm /s (cSt)
State voltage [V] and frequency [Hz]
** C -value (US) !O -value x 1.2
v v
Further Options (Valves)
Solenoid 9101 / 9151
XXXXX01.XXXX Normally open (NO), 0.1 to 16 bar,
Standard voltages
from DN 32 only with solenoid 9151
DC 1 AC 2 AC 2
XXXXX02
.XXXX Manual override
50 Hz 60 Hz
XXXXX03.XXXX Seat seal FPM,
24 V 24 V ¨
fluid temperature -5 !aC up to +110 !aC
¨ 110 V 120V
XXXXX14
.XXXX Seat seal EPDM,
¨ 230 V 220 V
for hot water,
Design acc. to DIN VDE 0580
fluid temperature ¨C20 !aC up to +110 !a
Voltage range !à10
0.3 to 16 bar up to DN 25
100 % duty cycle
Protection class acc. to EN 60529 IP65
0.3 to 10 bar from DN 32
Socket Form A acc. to DIN EN 175301-803 (included)
XXXXX47
.XXXX Flanges acc.to ASME B 16.5 150 lb/sq.In.
On request Further versions
Power Consumption
According to DIN VDE 0580 at coil temperature +20 !aC.
In operation the power consumption of the solenoid decreases by
approx. 30 %.
Further Options (Solenoids)
XXXXXXX.9136 Protection class
Solenoid
DC 1 AC 2
x II 2 GD EEx m II T4 T 130 !aC
Inrush Holding
with 3 m connection cable for AC/DC
9101 * 8 W 15 VA 12 VA / 7 W
XXXXXXX.
9186 Protection class
9151 * 18 W 45 VA 35 VA / 17 W
x II 2 GD EEx m II T4 T 140 !a
XXXXXXX.4682
Solenoid in protection class
* r coil only
x II 2 GD EEx md ll C T4/T5 T 130 !a
with cable gland for DC
Attention!
The conditions imposed on the Ex approvals lead to reduction of the
XXXXXXX.4683
Solenoid in protection class
permissible standard temperature ranges in the cases of explosion
x II 2 GD EEx md ll C T4/T5 T 130 !a
protected solenoids.
with cable gland for AC
On request Further versions
Part Number Nominal Diameter L H ? F max. ? B
(mm) (mm) (mm) (mm) (mm)
8303200.9101 15 130 69 96 44
8303300.9101 20 150 77 110 50
8303400.9101 25 160 81 115 62
8303500.9101 32 180 97 140 92
8303500.9151 32 180 114 140 92
8303600.9101 40 200 102 150 92
8303600.9151 40 200 119 150 92
8303700.9101 50 230 113 165 109
8303700.9151 50 230 131 165 109
Write a review
Your Name:Your Review: Note: HTML is not translated!
Rating: Bad Good
Enter the code in the box below: