actuator air Cylinder Solenoid Valve Transmitter SMC Parker Festo Schrader Miller Bosch Rexroth CKD Knorr Milwaukee Vickers Taiyo Numatics Mosier Allen Humphrey Koganei
Categories

Buschjost solenoid valve with differential pressure Norgren solenoid valve Series 83790

2/2-way high pressure solenoid valve DN 15
For compressed natural gas (CNG)
Indirectly solenoid actuated
Piston valves
83790
Internal threads G 3/4 - G1
Further customized solutions
Operating pressure 10 !- 250 ba
available upon request!
Description (standard valve)
8590649.9841
Switching function:  normally closed
Flow direction:  determined
Fluid temperature:
Solenoid 9841   ¨C20 !aC !- max. +60
Solenoid 9186   ¨C20 !aC !- max. +60
Ambient temperature:
Solenoid 9841   ¨C20 !aC !- max. +50
Solenoid 9186   ¨C20 !aC !- max. +40
Mounting position:  as required,  
preferably with solenoid vertical on top
8590556.9841
Material
Valve manifold:  Brass
Seat seal:  Polymer
Internal parts:  Brass / Stainless steel / Polymer
Internal leakage acc. to DIN EN 12266-1 Leakage rate !°E
External leakage acc. to DIN EN 12266-1 Leakage rate !°A
The installation of a 40 micron filter before the valve input is required!
Characteristic data
8590365.9841
Valves
Part Number Execution ND  Connection size Op. pressure * kv-value ** Weight
Solenoid with 1 or 2 (mm) min.       max.  (Base m3/h) total
  (bar) (kg)
8590649.9841 Single valve 15 G 3/4 10 250 4.5 4.8
2-station manifold   1 x G 1 Inlet
with integrated non return  2 x G 3/4 Outlet
8590556.9841 15 10 250 4.5 12.5
pressure valves for the 2-bank  2 x G 1/4 for
control Pressure transmitter***
3-station manifold   1 x G 1 Inlet
with integrated no return  3 x G 3/4 Outlet
8590365.9841 15 10 250 4.5 17.3
pressure valves for the 3-bank  3 x G 1/4 for
control
Pressure transmitter***
*  statistic test pressur PT=375 bar
**  C -value (US) !O  -value x 1.2
v v
*** not included
Acc. to PED 97/23/EC and ATEX 94/9/EC!
D119702.01
05/13

Series 83790  2/2-way high pressure solenoid valve DN 15
Solenoid 9841 Further Options (Solenoids)
Standard voltage XXXXXXX.9845  Solenoid with 10 m cable ends
Protection class according to
DC  1 AC 2
- II 2 G   Ex mb IIC T4 Gb
50 Hz ¨C 60 H
- II 2 D   Ex mb tb IIIC T 130 !aC D
24 V ¨ ¨
XXXXXXX.3826  for DC
¨ 230 V ¨
with 1/2 - 14 NPT female thread and
460?mm flying leads
Voltage range !à10
100 % duty cycle
Protection class acc. to ANSI/NEMA
Protection class acc. to EN 60529 IP65
USA: FM approved (File-No. 2Z2A6.AE)
Canada:  
XXXXXXX.9841
CSA certified (File-No. LR 57643-6)
Solenoid with 3 m cable ends
Solenoids in temperature class T3C
Protection class according to
(160 !aC) are usable in Ex-area
- II 2 G   Ex mb IIC T4 Gb
Class Division Groups
- II 2 D   Ex mb tb IIIC T 130 !aC D
Gases + fumes I 1 and 2 A !-
Dusts II 1 and 2 E !-
Solenoid 9186
Fibres and fluffs III 1 and 2 ¨
Standard voltage
Ambient temperature: ¨C20 !aC!- +60
DC  1 AC 2
40 Hz ¨C 60 H
XXXXXXX.3827  for AC  
with integrated rectifier
24 V ¨ ¨
with 1/2 - 14 NPT female thread and
¨ 230 V ¨
460?mm flying leads
Protection class acc. to ANSI/NEMA
Voltage range !à10
100 % duty cycle
USA: FM approved (File-No. 2Z2A6.AE)
Protection class acc. to EN 60529 IP65
Canada:
CSA certified (File-No. LR 57643-6)
XXXXXXX.9186
Solenoids in temperature class T3C
Solenoid with terminal box  
(160 !aC) are usable in Ex-area
cable gland M16 x 1.5  
Class Division Groups
cable gland diameter range ? 5-10 mm  
Gases + fumes I 1 and 2 A !-
Protection class according to
Dusts II 1 and 2 E !-
- EEx me II T4
- Ex II 2 GD  IP65 T 140 !a
Fibres and fluffs III 1 and 2 ¨
Ambient temperature: ¨C20 !aC !- +60
Power Consumption
XXXXXXX.428X  Solenoid with terminal box
According to DIN VDE 0580 at coil temperature of
cable gland M20 x 1,5  
+20?!aC. In operation the power consumption of the sol-
cable clamp ? 5!-8 m
noid decreases by approx. 30 %.
Protection class according to  
AC 2
- II 2 G   Ex e mb IIC T4/T5 Gb
Solenoid DC 1
Inrush Holding
- II 2 D   Ex tb IIIC T 130 !aC Db IP6
9841 10,1 W 9,2 VA 9,2 VA
Ambient temperature:
T4       ¨C40 !aC ... +50  
9186 14 W 16 VA 16 VA
T5       ¨C40 !aC ... +40
XXXXXXX.468X  Solenoid with terminal box
Cable gland Cable clamp
M20 x 1,5  10 !- 14 m
1/2 !- 14 NP  7.5 !- 11.9 m
Protection class according to  
- II 2 G   Ex d mb IIC T4/T5 Gb0  
- II 2 D   Ex tb IIIC T 130 !a
Ambient temperature:
T4       ¨C40 !aC !- +50
T5       ¨C40 !aC !- +40

Write a review

Your Name:


Your Review: Note: HTML is not translated!

Rating: Bad           Good

Enter the code in the box below:



Export Company Export Company Export Company Global Trade Leads - Import & Export on our award-winning International Trade Site