actuator air Cylinder Solenoid Valve Transmitter SMC Parker Festo Schrader Miller Bosch Rexroth CKD Knorr Milwaukee Vickers Taiyo Numatics Mosier Allen Humphrey Koganei
Categories

Buschjost solenoid valve with differential pressure Norgren solenoid valve Series 83580

2/2-way valves DN 65 to 150
For neutral gases and liquid fluids
Indirectly solenoid actuated
Diaphragm valves
Flange connection PN 16
Operating pressure 0.5 to 10 bar
Description (standard valve)
Solenoid valve for air, water, oil
Switching function:   Normally closed
Flow direction:   determined
Fluid temperature:  ¨C10 !aC to max. +90
Ambient temperature:  ¨C10 !aC to max. +50
Sum of fluid- and
ambient temperature:   max. +130 !a
Mounting position:   optional, solenoid preferably  
vertical on top
Material
Body:  Grey cast iron
Seat seal:  NBR
Internal parts::  1.4104, 1.4301, 2.1096, 2.0402
For contaminated fluids insertion of a strainer is recommended (see B accessories).
FeaturesAdjustable damped operation Easily interchangeable solenoid Insensitive to deposit Low power consumption 

Characteristic data
Valves
Part Number Nominal Diameter Operating pressure * K -value **
Weight
v
3
Solenoid with 1 or 2 (mm) min. (bar)                            max. (bar) (Base m
/h) (kg)
8358800.9366 65 0.5 10 56 21.3
8358900.9366 80 0.5 10 90 28.6
8359000.9366 100 0.5 10 150 40.2
8359100.9366 125 0.5 10 191 63.0
8359200.9366 150 0.5 10 277 93.0
2
State voltage [V] and frequency [Hz]
*  for gases and liquid fluids up to 40 mm /s (cSt)
** C -value (US) !O  -value x 1.2
v v
Solenoid 9366 Further Options (Valves)
XXXXX01.XXXX  Normally open
Standard voltages
On request   Further versions
DC 1 AC 2 AC 2
50 Hz 60 Hz
24 V 24 V ¨
Further Options (Solenoids)
On request  Further versions
¨ 110 V 120 V
¨ 230 V 220 V
Design acc. to DIN VDE 0580
Voltage range !à10
100 % duty cycle
Protection class acc. to EN 60529 IP65
Socket Form A acc. to DIN EN 175301-803 (included)
Power Consumption
According to DIN VDE 0580 at coil temperature +20 !aC.
In operation the power consumption of the solenoid decrea-
ses by approx. 30 %.
Solenoid
DC 1 AC 2
Inrush               Holding
9366 18 W 106 VA  35 VA

Part Number Nominal Diameter L H  F max.   A
(mm) (mm) (mm) (mm) (mm)
8358800.9366 65 290 185 185 190
8358900.9366 80 310 195 200 220
8359000.9366 100 350 220 220 250
8359100.9366 125 400 235 250 285
8359200.9366 150 480 265 285 330