For easy to view liquid level indication that is both accurate and nearly indestructible, nothing beats SureSite liquid level indicators. They are used in applications within every market segment where quick visual communication of tank contents is paramount. SureSite indicators operate without power, in temperatures to 750°F (399°C) and in pressures to 4200 psi (290 bar); they are unaffected by extreme thermal changes.
SureSites are a durable and safer alternative to breakable sight glasses. Featuring stainless steel, alloy or engineered plastic housings SiteSites mount externally to the top or sides of tanks to provide easy-to-read, continuous level gauging. The indicator is isolated from the measured media in a pressure-tight housing allowing SureSite indicators to be used in areas where sight glasses are not even a consideration. SureSite indicators are unaffected by tank shape, condensation, atmospheres, foam, stratification of vapors, high temperatures or flux and don’t require continual calibration. Modular accessories such as switches, scales and continuous transmitters increase control capabilities.
DIPTAPE tank level indicators are manually operated, compact and self-contained. Ideal for hazardous areas, they are non-electrical, plus liquids and vapors remain sealed from the atmosphere. Pop the cap, pull the tab and up comes the tape to tell you exactly how much liquid remains in the tank or drum. DIPTAPE indicators are designed for tanks up-to 6' (1.8 m) and are available in alloy, all PVC and engineered plastic versions.
Digital Bargraph Display Receivers -163000 Series
Gems Digital Bargraph Receivers improve the way you are able to visualize the data being received from your liquid level transmitters. These new receivers display liquid level information in digital numerals in conjunction with a 0-100% LED bargraph readout. The numeric portion is a 1/2? 4-digit display that provides detailed quantiication of tank contents, while the bright LED bargraph represents the tank contents as a bar length relative to the percentage of luid volume within the tank. If you have a non-linear tank, such as a sphere or a cylinder laying on its side, these receivers are a blessing. They can be calibrated easily so that the digital and bargraph displays will indicate accurate content information for !°odd!± shape tanks. Se
!°Linearization!± belo
In addition to the dual visual displays, the Gems Bargraph Receiver features two independent alarms with adjustable time delays, 10 amp auxiliary dry contacts and easy user set-up. The receiver is available in component form for mounting into custom enclosures or panels, or housed within a NEMA 4X enclosure.
Linearization
Certain tanks, like a sphere or a cylinder la
Easy to Adjust and Calibrate
Compact and Low Cost
Plainly Visible Readout
These compact, low-cost Level Cubes provide accurate, continuous 3-digit readout of liquid level. The indicating range and decimal point location on the display are quickly and easily selectable with the readout plainly visible.
Gems™ Receivers house a numerical digital readout, and all of the calibration adjustments for a complete Continuous Level indication system. Those receivers designed for the XM-Series transmitters also include a power supply for the transmitter.
3-Digit Level Cube Receivers
For use with GEMS Transmitters and SureSite Transmitters.These compact, low-cost Level Cubes provide accurate, continuous 3-digit readout of
liquid level. The indicating range and decimal point location on the display are quickly and easily selectable with the readout plainly visible. 3 Power Choices with NPT or Cable Mounted 9-V Battery Powered 9 VDC/117 VAC Powered Solar-Powered
GEMS GEMS
SOLAR CELL 2
AC ADAPTER
Part Numbers: Part Numbers: Part Numbers:
118600 !aCable Outpu 118620!aCable Outpu 118610!aCable Outpu
119250!a1/2? NP 119270!a1/2? NP 11926
DIPTAPE Indicators ¨C Alloy Version Temperatures to 300!aF (148!a Pressures to 750 PSI (52 bar)
Rugged brass or stainless steel units are ideal for use in water and oils. Select these units for best temperature and pressure capabilities.
1. Mounting Types
!°B!± Dimensio (Length Overall): Indicating Length + A + C
Brass
316 Stainless Steel Stem
or
with Carbon Steel or
Stem and Mounting Material
316 Stainless Steel
316 Stainless Steel Flange
Indicating Length**
6" to 72" (15.2 cm to 182.9 cm)
Std. Indication Markings
1/16" or 1 mm increments
2. Float Types
Float Part Number
73710 73709 138935
Min. Liquid Speciic Gravity
0.45 0.67 0.67
Oil: -40!aF to +230!
-40!aF to +300! -40!aF to +220!
Operating Temperatures
(-40!aC to +110!a
(-40!aC to +148.8!a (-40!aC to +104!a
Water: to 180!aF (+82.2!a
750 psi (52 bar) Mounting Type 3
Operating Pressure, Max.
300 psi (21 bar) max. @ 77!aF (25!a 150 psi (10 bar)
150 psi (10 bar) Mounting Type 4
!°A!± Dimension (From Mounting Type
1-1/4 (31.7 mm) 1-3/8 (34.9 mm) 1(25.4 mm)
!°C!± Dimension (From Mounting Type
11/16 (17.5 mm) 3/4 (19.05 mm) 9/16 (14.3 mm)
All-PVC Versions Are Economical for Light Duty Temperatures to 140!aF (60!a Pressures to 15 PSI (1 bar) Max. Ideal for chemical storage tanks, our all-PVC DIPTAPE Indicators provide one of your best values for liquid level monitoring. These light duty versions are recommended for use in calm liquids and ambient temperature and pressure levels. See Engineered Plastic versions on the next page for enhanced performance characteristics.
1. Mounting Types
!°B!± Dimension (Length Overall) Indicating Length +1-7/8? (47.6 mm)
Stem, Float and Mounting Material
PVC
Min. Liquid Specific Gravity
0.65
Operating Temperatures
0!aF to +140!aF (-17.7!aC to 60
Operating Pressure, Max.
15 psi (1 bar)
Indicating Length*
6" to 72" (15.2 cm to 182.9 cm)
Std. Indication Markings
1/16" or 1 mm increments
Easily Scaled in any Engineering Units From -19999 to 99999
Large 18mm (.71") High Red or Green Display
Front Panel MIN, MAX and Alarm Reset Functions
Strain Gauge Meters for Millivolt Transducers
Process Meters for Amplified Transducers
High or Low Alarms
The DM28 meter line is easily programmed to read out in any engineering units (psi, bar, Kg/cm2) and can be retro fitted in the field with plug in boards. Units can be scaled by applying known loads to the sensors or purely by software keystrokes without requiring any electronic instrumentation. Scaling for the meter using up to 10 points can compensate for non-linear signals and profiling curved tanks in level applications. The display color (red or green), latching or non-latching alarms and the optional analog outputs are all programmable. The meter also features a help character that indicates max, min, and normal operation, it also gives additional help when programming. The DM28 meter line is available in 5 different models.
Applications:
Medical Laboratory
Food and Beverage Systems
Pharmaceuticals
Petrochemicals
Leak Detection
Hydraulic Reservoirs
High Performance Versions ¨C
Standard Size Designed to meet the requirements of ASME B31.1/B31.3* Temperatures to 750!aF (399!a Pressures to 4200 PSI (290 bar)
For your most demanding applications, these SureSite Indicators feature ANSI langes and ittings and construction to rigorous ASME standards. You can!ˉt specify a better visual level indicator
1. Mounting Coniguration Types
To choose the best coniguration for your application, focus on the process connections (connections where the liquid typically enters/leaves the SureSite).
2. Material
Select desired material from those tabulated below. Mark the Code Number on your OrderIt! Check List. The pressure/temperature performance parameters are speciied in the chart at right. Consult the factory with pressure/temperature requirements that fall outside the parameters shown here. These units are manufactured in Schedule 40, 80 or 160 pipe accordingly.
Lengths over 20ft (6.09 m)
316 Stainless Steel Housing
Pressures up to 400 psi (27 bar)
Temperatures up to 400°F (204°C)
Alloy Versions¨CMiniature SizLengths to over 20 feet (6.1 meters)316 Stainless Steel constructionPressures to 400 PSI (27 bar) ¨C Temperature to 400!aF (204!
Use these Mini SureSite® Level Gauges where space is tight—they feature a diameter of only 1-1/4” (32 mm)! They can replace existing, antiquated sightglasses for excellent external, visual liquid level indication. Mini SureSite® Indicators are ideal for use with clean, low viscosity liquids.
Applications:
Pharmaceuticals
Medical Equipment
Food and Beverages
Semiconductor Manufacturing
Boilers
Temperatures up to 280°F (139°C)
Pressures up to 150 psi (10 bar)
Up to 20ft (6.09 m) of Continuous Visual Indication
The 2” (51 mm) Schedule 40 pipe design is ideal for use on chemical storage tanks, or with almost any liquid where temperature and pressure requirements are moderate. All SureSite® Level Gauges feature the same patented flag and guide assemblies used on our alloy versions, so you can be assured of excellent visibility and long-life reliability.
Accessory Options: Transmitters, Indicating Scales and Switch Modules
1. Mounting Coniguration Types
To choose the best coniguration for your application, focus on the process connections (connections where the liquid typically enters/leaves the SureSite).
2. Material
Select desired material from those tabulated below. Mark the Code Number on your OrderIt! Check List. The pressure/temperature performance
parameters are speciied in the charts at right. Consult the factory with pressure/ temperature requirements that fall outside the parameters shown
here.
Temperatures up to 750°F (399°C)
Pressures up to 700 psi (48 bar)
Standard Alloy Versions ¨C Standard SizTemperatures to 750!aF (399!aPressures to 700 PSI (48 bar)
Rugged, welded construction makes these 2-1/2? (63.5 mm) diameter design, alloy SureSite Indicators dependable over a long service life indoors and out.
1. Mounting Coniguration Types
To choose the best coniguration for your application, focus on the process connections (connections where the liquid typically enters/leaves the SureSite).
2. Material
(62) Housing and Float: 316 Stainless Steel Pressure/Temperature performance parameters for alloy SureSite versions are speciied in the chart at right. Please consult the factory with temperature/pressure
600 requirements that fall outside the parameters shown here.