actuator air Cylinder Solenoid Valve Transmitter SMC Parker Festo Schrader Miller Bosch Rexroth CKD Knorr Milwaukee Vickers Taiyo Numatics Mosier Allen Humphrey Koganei
Categories

HYDAC Electronic pressure transmitter for shipbuilding and offshore HDA 4000

Description:
This pressure transmitter has been specially developed for shipbuilding and offshore applications and is based on the HDA 4000 series. By using ceramic measurement cells, absolute and relative pressure measurements can be made in the low pressure range.  Stainless steel measurement cells are used for measuring in the high pressure range. The evaluation electronics using HYDAC-
ASIC converts a measured pressure into a proportional analogue signal of 4 .. 20 mA. The electronic module is completely sealed to protect it against humidity, vibrations and shock, and is enclosed in a solid stainless steel housing. For use in the shipbuilding industry, these pressure transmitters have the following approvals:

Binder connection, Series 714

Technical specifications:
Input dataHDA 4100HDA 4300HDA 4400HDA 4700
Measuring ranges / [bar]1; 2.5 (absolute)1; 2.5; 4; 6; 10; 16; 25;6; 16; 40; 60; 100; 250;6; 16; 40; 60; 100; 250,
40400; 600400; 600
-1..1; -1..5; -1..9 (relative)
Measuring ranges / [psi]15; 5015; 30; 50; 100; 150;150; 750; 1000; 1500;150; 750; 1000; 1500;
250; 5003000; 5000; 6000; 9000 3000; 5000; 6000; 9000
Overload pressures200 % FS200 % FS200 % FS, max. 900 bar200 % FS, max. 900 bar
(13050 psi)(13050 psi)
Burst pressures400 % FS, max. 12 bar400 % FS, max. 300 bar400 % FS, max. 2000 bar400 % FS, max. 2000 bar
 (170 psi) (4350 psi)(29000 psi)(29000 psi)
Parts in contact with mediaCeramic, stainless steelCeramic, stainless steelStainless steel;Stainless steel,
Seals: FPM,Seals: FPM,Seal: FPM,Seal: FPM,
EPDMEPDM
Output data
Curve deviation at  !à 1 % FS max  !à 1 % FS max  !à 1 % FS max  !à 0.5 % FS max
max. setting to  !à 0.5 % FS typ  !à 0.5 % FS typ  !à 0.5 % FS typ  !à 0.25 % FS typ
DIN 16086
(accuracy class)
Curve deviation at  !à 0.5 % FS max  !à 0.5 % FS max  !à 0.5 % FS max  !à 0.25 % FS max
min. setting to  !à 0.25 % FS typ  !à 0.25 % FS typ  !à 0.25 % FS typ  !à 0.15 % FS typ
(B.F.S.L)
Temperature compensation  !à 0.3 % / 10 K ma  !à 0.3 % / 10 K ma  !à 0.25 % / 10 K ma  !à 0.15 % / 10 K max
zero point  !à 0.2 % / 10 K typ  !à 0.2 % / 10 K typ  !à 0.15 % / 10 K typ  !à 0.08 % / 10 K typ  !à 0.3 % / 10 K max  !à 0.3 % / 10 K ma  !à 0.25 % / 10 K max  !à 0.15 % /1 0 K max
Temperature compensation
over range  !à 0.2 % / 10 K typ  !à 0.2 % / 10 K typ  !à 0.15 % / 10 K typ  !à 0.08 % / 10 K typ
Linearity at max.  !à 0.5 % FS max  !à 0.5 % FS max  !à 0.3 % FS max  !à 0.3 % FS max
setting to  !à 0.25 % FS typ  !à 0.25 % FS typ  !à 0.15 % FS typ  !à 0.15 % FS typ
DIN 16086
Hysteresis  !à 0.25 % FS max  !à 0.25 % FS max  !à 0.4 % FS max  !à 0.1 % FS max  !à 0.125 % FS typ  !à 0.125 % FS typ  !à 0.2 % FS typ  !à 0.05 % FS typ
Repeatability  !à 0.1 % F  !à 0.1 % F  !à 0.1 % F  !à 0.05 % F
Rise timeapprox. 2 msapprox. 2 msapprox. 2 msapprox. 2 ms
Long-term drift  !à 0.3 % FS typ. / yea  !à 0.3 % FS typ. / yea  !à 0.3 % FS typ. / yea !à 0.1 % FS typ. / yea
Ambient conditions
Nominal temperature range   0 ..   +80 !aC   0 ..   +80 !aC-25 ..   +85 !aC-25 ..   +85
Operating temperature range -25 ..   +85 !aC *-25 ..   +85 !aC *-25 ..   +85 !aC **-25 ..   +85 !a
Storage temperature range-30 .. +100 !aC-30 .. +100 !aC-40 .. +100 !aC-40 .. +100
Fluid temperature range-25 .. +100 !aC *-25 .. +100 !aC *-25 .. +100 !aC **-25 .. +100 !a
 - markEN 61000-6-1/2/3/4EN 61000-6-1/2/3/4EN 61000-6-1/2/3/4EN 61000-6-1/2/3/4
Vibration resistance to  20 g (196.2 m/s2) 20 g (196.2 m/s2)  20 g (196.2 m/s2)  20 g (196.2 m/s2)
IEC 68-2-6 at
10 .. 500 Hz
Protection class  toModels withModels withModels withModels with
DIN 40050connectors:connectors:connectors:connectors:
IP 65IP 65 IP 65IP 65
Other data
Supply voltage10 .. 32 V10 .. 32 V10 .. 32 V10 .. 32 V
2-conductor
Residual ripple
of supply voltage  5 %  5 %  5 %  5 %
Reverse polarityprovidedprovidedprovidedprovided
protection of the supply
voltage, excess voltage,
override and short circuit
protection
Life expectancy10 million load cycles10 million load cycles10 million load cycles10 million load cycles
0 .. 100 % FS0 .. 100 % FS0 .. 100 % FS0 .. 100 % FS
Weightapprox. 150 gapprox. 150 gapprox. 150 gapprox. 150 g

Write a review