Anderson pressure transmitter
Anderson Instrument Company designs and manufactures a broad line of sanitary process instrumentation for customers in Fluid Food & Beverage, Dairy and the Biopharmaceutical Industries. By specifying Anderson Products, customers are assured that their sanitary instrumentation will meet or exceed all requirements for performance, reliability, cleanability, and sterilization.
Anderson's newest sanitary pressure transmitter improves upon the solid performance of the standard HA by allowing the device to be autoclaved in place. Improved enclosure integrity and tighter accuracy and stability will make this the transmitter of choice in both autoclave and critical applications.
Response Time: 200 uSec
Output: 4-20 mA DC, 2 wire
Accuracy: !Ã 0.4% of full scal
Repeatability: !Ã 0.2% of full scal
Hysteresis: !Ã 0.10% of full scal
Sanitary pressure gauges and transmitters that can be installed on lines as small as 1/2" without the need for adapters or reducers, without creating pockets or "dead legs", and without sacrificing performance.
Anderson's newest sanitary pressure transmitter is specifically designed for critical measurements in fractional size lines. This product replaces the two piece fractional transmitter with a very compact, single piece transmitter.
Excitation:
10-40 VDC (Absolute), 24 VDC Nominal regulated or unregulated.
Output:
4-20 mA DC, 2 wire with non-interrupting circuit verification test points
Loop Resistance:
0-700 ohms at 24 VDC
Wiring Connection:
16 AWG max.; Screw Terminal; Accessible via removable screw cap conduit housing
Recommended Cable:
22-24 AWG, foil shielded, and PVC coated.(3/16 - 1/4 OD insulation)
Accuracy: 0.5% of Full Scale
Repeatability: 0.3% of full scale
Hysteresis: 0.25% of full scale
Linearity:0.10% of full scale
Stability:.25% of calibrated range/6 months
Storage Temperature:-40 to 149F (-40C to 65C)
Process Temperature Limits: 30 to 300F (-1C to 149?C)
(Horizontal Mount recommended over 275F)
Ambient Temperature Limits:40 to 120 F (4 to 49?C)
Effect of Temperature Change: 0.1 psig/10F typical
Over-Range Rating:2 times base range
Wetted Parts:316L stainless steel electropolished (R max. = 8 microinches, .2 mic
A 3-A compliant stainless steel diaphragmed version of our ultra low profile series. The HH is ideal for preassembled skids destined for the wet environments found in dairies, beverage and food processing facilities.
Excitation: 10-40 VDC (Absolute), 24 VDC Nominal
Response Time: 200 uSec
regulated or unregulated
Wetted Parts: 316L stainless steel
Output: 4-20 mA DC, 2 wire with non-interrupting
(Ra max. = 25 microinches, 0.6 microns)
Housing Material: 304 stainless steel
Loop Resistance: 0-700 ohms at 24 VDC
Span Adjustment: !Ã 50% of range, except 15 psi !Ã 1
Wiring Connection: 5 pin M12 Quick Disconnect Receptacle
Zero Adjustment: 10%
Recommended Cable:
Mounting: Direct connection
(4-8mm (0.16-0.31!±) cable sheath OD)
Standards: Designed and manufactured to sound
Accuracy: !Ã 0.5% of full scal
engineering practices in accordance with
Repeatability: !Ã 0.3% of full scal
Article 3.3 of the PED 97/
A member of Anderson’s Next Generation Platform, the MPF Food/Beverage/Dairy pressure transmitter provides a fully modular design, internal diagnostic display, and superior environmental protection. State of the Art performance delivers accuracy to 0.1% of calibrated range with class leading stability. Broadly configurable, 24 v DC,Loop powered (2 wire) 4 – 20 mA output with available HART 7.0
Performance mechanical & electrical:
Calibrated Accuracy: !Ã 0.10% of calibrated range up to 5:1 turndow
(!Ã 0.15% if over 5:1 turndown
Repeatability: 0.05% as calibrated
Long Term Stability: 0.2% URL for 2 years
Process Temperature Effect: !Ã 0.1 psi/10!aF (5.5!aC) typi
Ambient Temperature Effect: !Ã 0.1 psi/10!aF (5.5!aC) typi
Over-Range Capability: 30/100/500 psi stem:
1.5x URL no effect on accuracy
2x URL to failure
1000 psi stem:
1.1x URL no effect on accuracy
1.25x URL to failure
Response Time: <100 Milliseconds
Sampling Rate: <50 Milliseconds
Damping: Menu adjustable
Range T
Designed specifically for the needs of the Life Science market the MPP Pharmaceutical Series Pressure Transmitter provides state of the art performance in a superior sanitary package. Developed from Anderson’s Next Generation Modular Platform the MPP delivers class leading performance while providing the benefits of a modular architecture, assembled in an ASME –BPE compliant design. The MPP is 24 v DC, Loop powered (2 wire) 4 – 20 mA output with HART 7.0
Performance mechanical & electrical:
connector
enVironmental:
source
construction / finish:
aPProVals and documentation
Warranty:
The Anderson SR offers not only a new low profile design, but may be ordered with built-in LCD indication.
Excitation:9-32 VDC (Absolute), 24 VDC Nominal, regulated or
unregulated
14-37 VDC (Absolute) with display
Output:4-20 mA DC
Loop Resistance:0-750 ohms at 24 VDC
0-1050 ohms at 30 VDC
Indication:Optional, 3 1/2 digit, .5" high LCD, cap mounted
Accuracy: 0.5% of span, full scale, for standard ranges, ranges
below 0-50 psig
1% full scale; all compound and psia ranges,
1.5% full scale
Over-Range Rating:2 times base range
Stability: 0.3% of calibrated range/6 months
Storage Temperate:-40 to 150?F (-40 to 65?C)
Zero and Span Adjustment: 10% of range
Repeatability: .3%
Hysteresis: .2%
Process Temp. Range:20? to 225?F (up to 300?F if horizontal mount)
Process Temp. Effect:Less than 0,2% of full scale output/10?F change
Ambient Temp. Operating Range:0? to 120?F (-17.8? to 48.9?C)
Storage Temperature:-40? to 149?C (-40? to 65?C)
Mounting:Direct connection
Housing Material:304 Stainless Steel
Wetted Parts:316L Stainless Steel standard; Hasteloy "C" diaphragm
optional
Surface Finish (wetted parts):R = 25 microinches (.6 microns)
The Anderson SV Pharmaceutical Series Pressure Transmitter offers not only a new low profile design, but may be ordered with built-in LCD indication.
Excitation:9-32 VDC (Absolute), 24 VDC Nominal, regulated or
unregulated
14-37 VDC (Absolute) with display
Output:4-20 mA DC
Loop Resistance:0-750 ohms at 24 VDC
0-1050 ohms at 30 VDC
Indication:Optional, 3 1/2 digit, .5" high LCD, cap mounted
Accuracy: .5% of span, full scale, (for standard ranges)
(Includes Hysteresis, 1.0% of span, full scale, (for ranges below 0-50 psig,
Repeatability, and Linearity)and all compound/psia ranges)
Over-Range Rating:2 times base range
Stability: 0.3% of calibrated range/6 months
Storage Temperate:-40 to 150F (-40 to 65?C)
Zero and Span Adjustment: 10% of range
Repeatability: .3%
Hysteresis: .1%
Linearity ? .1%
-6.7 to 135?C (up to 163C if horizontal mount)
Process Temp. Range:20 to 275?F (up to 325F if horizontal mount)
Process Temp. Effect:Less than 0.2% of full scale output/10F change
Ambient Temp. Operating Range:-17.8 to 48.9C (0 to 120F)
Storage Temperature:-40 to 65C (-40 to 149F)
Mounting:Direct connection
Housing Material:316 Stainless
Our "T" Series pressure transmitter is a microprocessor-based sensor specifically designed for sanitary fluid process applications in the food and beverage industry.
The Anderson "T" series pressure transmitter is a microprocessor-based sensor specifically designed for sanitary fluid process applications in the pharmaceutical and biotechnology industries.
Ranges:
Rangeability (Turn-down):
Over Pressure Limit: Accuracy*
Over Pressure Output: Sensor Style 1 & 2: Above 110% of
calibrated range - 3.8 mA
pressure output
Mechanical Trim Adjustments: Repeatability:
Hysteresis:
Output:
Linearity (BFSL):
Stability:
Power Supply:
Indication: Optional, cap-mounted, LCD Indication
max = 8 Wetted Material Surface Finish: Electropolished to R
a
Temperature Limits (Process):
Wetted Material:
Housing Material:
Actuating Fill:
Hazardous Locations Compliance:
Housing Ratings:
UL Compliance with Class 1, Div. 1, Groups A thru D
Electrical Connections:
for intrinsically safe apparatus, when connected with approved For sensor type
1 & 2 ONLY
Standards:
Process Temperature Effect:
Showing 1 to 10 of 10 (1 Pages)