Anderson SV Pharmaceutical Series Pressure Transmitter
The Anderson SV Pharmaceutical Series Pressure Transmitter offers not only a new low profile design, but may be ordered with built-in LCD indication.
Excitation:9-32 VDC (Absolute), 24 VDC Nominal, regulated or
unregulated
14-37 VDC (Absolute) with display
Output:4-20 mA DC
Loop Resistance:0-750 ohms at 24 VDC
0-1050 ohms at 30 VDC
Indication:Optional, 3 1/2 digit, .5" high LCD, cap mounted
Accuracy: .5% of span, full scale, (for standard ranges)
(Includes Hysteresis, 1.0% of span, full scale, (for ranges below 0-50 psig,
Repeatability, and Linearity)and all compound/psia ranges)
Over-Range Rating:2 times base range
Stability: 0.3% of calibrated range/6 months
Storage Temperate:-40 to 150F (-40 to 65?C)
Zero and Span Adjustment: 10% of range
Repeatability: .3%
Hysteresis: .1%
Linearity ? .1%
-6.7 to 135?C (up to 163C if horizontal mount)
Process Temp. Range:20 to 275?F (up to 325F if horizontal mount)
Process Temp. Effect:Less than 0.2% of full scale output/10F change
Ambient Temp. Operating Range:-17.8 to 48.9C (0 to 120F)
Storage Temperature:-40 to 65C (-40 to 149F)
Mounting:Direct connection
Housing Material:316 Stainless Steel
Wetted Parts:316L Stainless Steel standard; Hasteloy "C" diaphragm
optional
Surface Finish (wetted parts):R
max = 8 microinches (.2 microns) electropolished
a
Recommended Cable:18-24 AWG, foil shielded, and PVC coated.
(3/16" - 1/4" O.D. insulation)
Wiring Connection:Screw Terminal; Accessible via removable screw cap
conduit housing