The Anderson SR offers not only a new low profile design, but may be ordered with built-in LCD indication.
Excitation:9-32 VDC (Absolute), 24 VDC Nominal, regulated or
unregulated
14-37 VDC (Absolute) with display
Output:4-20 mA DC
Loop Resistance:0-750 ohms at 24 VDC
0-1050 ohms at 30 VDC
Indication:Optional, 3 1/2 digit, .5" high LCD, cap mounted
Accuracy: 0.5% of span, full scale, for standard ranges, ranges
below 0-50 psig
1% full scale; all compound and psia ranges,
1.5% full scale
Over-Range Rating:2 times base range
Stability: 0.3% of calibrated range/6 months
Storage Temperate:-40 to 150?F (-40 to 65?C)
Zero and Span Adjustment: 10% of range
Repeatability: .3%
Hysteresis: .2%
Process Temp. Range:20? to 225?F (up to 300?F if horizontal mount)
Process Temp. Effect:Less than 0,2% of full scale output/10?F change
Ambient Temp. Operating Range:0? to 120?F (-17.8? to 48.9?C)
Storage Temperature:-40? to 149?C (-40? to 65?C)
Mounting:Direct connection
Housing Material:304 Stainless Steel
Wetted Parts:316L Stainless Steel standard; Hasteloy "C" diaphragm
optional
Surface Finish (wetted parts):R = 25 microinches (.6 microns) for standard finish;
a
R max = 8 microinches (.2 microns) for electropolished
a
fittings (specify when ordering)
Recommended Cable:18-24 AWG, foil shielded, and PVC coated.
(3/16" - 1/4" O.D. insulation)
Wiring Connection:Screw Terminal; Accessible via removable screw cap
conduit housing