Anderson MPF Modular Pressure Transmitter
A member of Anderson’s Next Generation Platform, the MPF Food/Beverage/Dairy pressure transmitter provides a fully modular design, internal diagnostic display, and superior environmental protection. State of the Art performance delivers accuracy to 0.1% of calibrated range with class leading stability. Broadly configurable, 24 v DC,Loop powered (2 wire) 4 – 20 mA output with available HART 7.0
Performance mechanical & electrical:
Calibrated Accuracy: !à 0.10% of calibrated range up to 5:1 turndow
(!à 0.15% if over 5:1 turndown
Repeatability: 0.05% as calibrated
Long Term Stability: 0.2% URL for 2 years
Process Temperature Effect: !à 0.1 psi/10!aF (5.5!aC) typi
Ambient Temperature Effect: !à 0.1 psi/10!aF (5.5!aC) typi
Over-Range Capability: 30/100/500 psi stem:
1.5x URL no effect on accuracy
2x URL to failure
1000 psi stem:
1.1x URL no effect on accuracy
1.25x URL to failure
Response Time: <100 Milliseconds
Sampling Rate: <50 Milliseconds
Damping: Menu adjustable
Range Turndown Capability: 10 to 1 turn down from URL
Ranges, URL (PSI): 30,100,500,1K gauge and compound 30,100,500 absolute
Ranges, URL (BAR): 2,7,35,70 gauge and compound 2,7,35 absolute
enVironmental:
Process Temperature Limits: 0 to 350!aF (-18 to 177!aC) with ambient temperatures to 140!aF (60!aC) and 0 to 330!aF (0 to 7
with ambient temperatures to 160!aF (71!a
Ambient Temperature Limits: 32 to 160!aF (0 to 71!a
Enclosure Protection: NEMA 4X & IP66
IP69K(when equipped with QDR)
construction / finish:
Non-Product Contact Plastic: polycarbonate threaded cap. Delrin atmospheric vent
Wiring Connection: M16 x 1.5 threaded housing electrical entry
Equipped with:
Standard - replaceable M12 5 pin Eurofast QDR
Optional - M16 Cord Grip, M16 x 1.5" NPTF adaptor
oPerational:
Output: 2 wire user selectable 4-20 mA DC or 20-4 mA
Internal Display: 4 digit LED nominally displays loop current. Process variable selectable - PSI or BAR.
Loop Resistance: 0-300 ohms at 24 VDC
Electrical Connection: screw terminals with a conductor cross section range of 14-26 AWG
Recommended Cable: Anderson shielded molded cordset, alternatively: 22-24 AWG, foil shielded, 0.17 - 0.26!± Cable Sheath
Operating Voltage: 18-36 VDC (24 VDC Nominal regulated or unregulated)
Zero Adjustment: one touch
Re-Span: With switch through user interface & with or without a reference pressure source
aPProVals and documentation
Compliance: Compliant with the Pressure Equipment Directive relative to Sound Engineering Practices(PED)
CSA-B51-03
CRN# CSAOF9754.5R1
Warranty: 2 years