Noshok pressure transmitter
For nearly half a century NOSHOK has been a pioneer in our industry by continually providing innovative solutions, unparalleled customer support, outstanding value and a broad offering of premium quality product lines.
Established in 1967, NOSHOK, Inc. was one of the first companies to offer a liquid filled pressure gauge. This leading-edge feature slowly caught on as the industry began to recognize the extended service life and enhanced performance that a liquid filled pressure gauge offers. Since those early years, we’ve built on that foundation of quality and value, and grown to be an industry leader in the international marketplace, delivering Measurement Solutions to a wide variety of industries including oil & gas, fluid power, general industrial, automation, chemical processing, manufacturing, water & waste water, food & beverage, and many more.
We continue to forge ahead with our continually-expanding product offering, industry- leading warranties and forward-thinking customer support tools such as our mobile web site, one of the first of its kind in our marketplace.
SPECIFICATIONS
Output signal
4 mA to 20 mA, 2-wire
Pressure ranges
Standard gauge ranges from vacuum to 15,000 psi;
Standard absolute ranges from 15 psia to 300 psia
Proof pressure
3 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 to 15,000 psi range
Burst pressure
3.8 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 to 15,000 psi range
Accuracy
± 0.5 % full scale (BFSL);optional ± 0.25% full scale (BFSL)
(Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors)
Repeatability
≤ ± 0.05% full scale
Hysteresis
≤ ± 0.1% full scale
Stability
≤ ± 0.2% full scale for 1 year, non-accumulating
Response time
≤1 ms (between 10% and 90% full scale)
Power supply*
10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire)
L
SPECIFICATIONS
Output signals
0 Vdc to 5 Vdc, 3-wire; 0 Vdc to 10 Vdc, 3-wire; 1 Vdc to 5 Vdc, 3-wire;
1 Vdc to 6 Vdc, 3-wire; 1 Vdc to 11 Vdc, 3-wire;
Pressure ranges
Standard gauge ranges from vacuum to 15,000 psi;
Standard absolute ranges from 15 psia to 300 psia
Proof pressure
3 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15000 psi range
Burst pressure
3.8 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi range
Accuracy
± 0.5 % full scale (BFSL);
± 1.0% terminal point;
± 0.25 % optional (Includes the combined effects of linearity, hysteresis and repeatability)
Repeatability
≤ ± 0.05% full scale
Hysteresis
≤ ± 0.1% full scale
Stability
≤ ± 0.2% full scale per year, non-accumulating
Response time
≤1 ms (between 10% and 90% full
SPECIFICATIONS
Output signals
4 mA to 20 mA, 2-wire;
1 Vdc to 5 Vdc, 1 Vdc to 6 Vdc, 1 Vdc to 11 Vdc, 3-wire;
0 Vdc to 5 Vdc and 0 Vdc to 10 Vdc, 3-wire;
0 Vdc to 5 Vdc and 0 Vdc to 10 Vdc, 4-wire
Pressure ranges
Standard gauge ranges from vacuum to 145,000 psig;
Standard absolute ranges trom 15 psia to 300 psia
Proof pressure
3 times full scale for ranges 0 psi to 2 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15,000 psi range
1.2 times full scale for ranges 0 psi to 20,000 psi through 0 psi to 145,000 psi
Burst pressure
3.8 times full scale for ranges 0 psi to 2 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi range
1.5 times full scale for ranges 0 psi to 20,000 psi through 0 psi to 145,000 psi
Accuracy
± 0.25 % full scale (BFSL); optional ± 0.125% full scale (BFSL); (includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full sc
SPECIFICATIONS
Output signals
4 mA to 20 mA, 2-wire;
0 Vdc to 5 Vdc and 0 Vdc to 10 Vdc, 3-wire;
RS232-C digital output;
USB
Pressure ranges
Standard gauge ranges from vacuum to 15,000 psig
Standard absolute ranges from 15 psia to 300 psia
Proof pressure
3 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
2 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15,000 psi range
Burst pressure
4 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi range
Accuracy
± 0.05 % full scale (Best Fit Straight Line); Optional ±0.025%full scale (Best Fit Straight Line);
(Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors)
Hysteresis
≤ ± 0.03% full scale
Stability
≤ ± 0.1% full scale; 5 psi ± 0.2% full scale per year
Power supply*
9 Vdc to 30 Vdc (4 mA to 20 mA, 2-w
SPECIFICATIONS
Output signal
4 mA to 20 mA 2-wire, 1 Vdc to 5 Vdc 3-wire;
0.1 Vdc to 10 Vdc, 3-wire
Pressure ranges
Standard gauge ranges from 200 psig to 15,000 psig
Proof pressure
2 times full scale for ranges 0 psi to 200 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15,000 psi range
Burst pressure
9 times full scale for 0 psi to 200 psi through 0 psi to 1,000 psi
3 times full scale for ranges 0 to 3,000 psi through 0 psi to 15,000 psi
Accuracy
± 0.25% full scale (BFSL); (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors)
Repeatability
≤ ± 0.05% full scale
Hysteresis
≤ ± 0.5% full scale
Stability
≤ ± 0.2% full scale for 1 year, non-accumulating
Response time
< 2 ms (between 10% and 90% full scale)
Power supply*
10 Vdc to 36 Vdc (4 mA to 20 mA, 2-wire)
8 Vdc to 36 Vdc (1 Vdc to 5 Vdc, 3-wire)
14 Vdc to 36 Vdc (0.1 Vdc to 10 Vdc, 3-wire)
Load limitations
Requires 10 Vdc across transmitter connect
SPECIFICATIONS
Output
4 mA to 20 mA, 2-wire
Accuracy
±0.05% full scale (BFSL); ±0.15% full scale for 0 psig to 15,000 psig range;
(Includes the effects of non-linearity, hysteresis,non-repeatability, zero point
and full scale errors)
Total accuracy
± 0.05 % full scale (BFSL) including the effects of linearity, hysteresis, repeatability and thermal effects from 50 °F to 104 °F; ±0.15 % full scale for 0 psig to 15,000 psig
Hysteresis
≤ ± 0.04% full scale
Repeatability
≤ ± 0.05% full scale
Stability
≤ ± 0.1% full scale for 1 year non-accumulating
Pressure ranges
Standard ranges from vacuum through 15,000 psig
Proof pressure
5 times full scale for ranges 0 psi to 5 psi through 0 psi to 250 psi
2 times full scale for ranges 0 psi to 500 psi through 0 psi to 7,500 psi
1.5 times full scale for 0 psi to 15,000 psi range
*Proof pressure is based on full scale range prior to turndown
Burst pressure
6 times full scale for ranges 0 psi to 5 psi through 0 psi to 250 psi
4 times full scale for ranges 0 psi to 500 psi t
Showing 1 to 6 of 6 (1 Pages)