actuator air Cylinder Solenoid Valve Transmitter SMC Parker Festo Schrader Miller Bosch Rexroth CKD Knorr Milwaukee Vickers Taiyo Numatics Mosier Allen Humphrey Koganei
Categories

Noshok 200 Series Voltage Output Pressure Transducers

SPECIFICATIONS
Output signals 0 Vdc to 5 Vdc, 3-wire; 0 Vdc to 10 Vdc, 3-wire; 1 Vdc to 5 Vdc, 3-wire;
1 Vdc to 6 Vdc, 3-wire; 1 Vdc to 11 Vdc, 3-wire;
Pressure ranges Standard gauge ranges from vacuum to 15,000 psi;
Standard absolute ranges from 15 psia to 300 psia
Proof pressure 3 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15000 psi range
Burst pressure 3.8 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi range
Accuracy ± 0.5 % full scale (BFSL);
± 1.0% terminal point;
± 0.25 % optional (Includes the combined effects of linearity, hysteresis and repeatability)
Repeatability ≤ ± 0.05% full scale
Hysteresis ≤ ± 0.1% full scale
Stability ≤ ± 0.2% full scale per year, non-accumulating
Response time ≤1 ms (between 10% and 90% full scale)
Power supply* 10 Vdc to 30 Vdc  (0 Vdc  to 5 Vdc, 3-wire)
10 Vdc to 30 Vdc  (1 Vdc  to 5 Vdc, 3-wire)
10 Vdc to 30 Vdc  (1 Vdc  to 6 Vdc, 3-wire)
14 Vdc to 30 Vdc  (0 Vdc to 10 Vdc, 3-wire)
14 Vdc to 30 Vdc  (1 Vdc  to 11 Vdc, 3-wire)
Load limitations ≥ 5,000 for 0 Vdc to 5 Vdc, 1 Vdc to 5 Vdc, and 1 Vdc to 6 Vdc outputs;
≥ 10,000 for 0 Vdc to 10 Vdc and 1 Vdc to 11 Vdc outputs.
Current consumption 8 mA
Wetted materials 316 stainless steel for vacuum through 300 psi;
17-4PH stainless steel sensing diaphragm and 316 stainless steel pressure connection for higher ranges
Housing materials 316 stainless steel
Adjustment ± 10% full scale for zero and span
Pressure cycle limit 150 Hz
Durability > 100,000,000 full scale cycles
Temperature ranges Compensated 32 °F to 176 °F (0 °C to 80 °C)
Effect ± 0.017 % full scale/°F for zero and span
Ambient -40 °F to 185 °F (-40 °C to 85 °C)
Media -22 °F to 212 °F (-30 °C to 100 °C)
Storage -40 °F to 212 °F (-40 °C to 100 °C)
Environmental rating IP65, NEMA 4X according to EN 60529/IEC 529
Electromagnetic rating CE compliant to EMC norm EN 61326:1997/A1:1998
RFI, EMI and ESD protection
Electrical protection Reverse polarity, over-voltage and short circuit protection
Shock 1000 g's per IEC 770
Vibration 30 g's per IEC 770
Weight Approximately 3.5 oz.
  • Highly repeatable, shock resistant transducers with excellent long-term stability
  • Standard ranges from vacuum to 15,000 psi; Standard Absolute ranges from 15 psia to 300 psia
  • Accuracy up to ±0.25% Full Scale (BFSL)
  • Compact size, affordable price
  • Advanced diffused semi-conductor and sputtered thin film sensor for maximum stability
  • Welded stainless steel pressure chamber
  • High alternating load resistance
  • High overpressure protection
  • Compatible with NOSHOK Smart System Indicators
  • CE compliant to suppress RFI, EMI and ESD, combined with reverse polarity and over-voltage protection to ensure reliable performance in the most demanding applications
  • Final calibration tests prior to shipment ensures 100% "out of the box" reliability
SERIES 200                  
PRESSURE
RANGES
30vac -30 inHg to 0 psig 30/300 -30 inHg to 300 psig 200 0 psig to 200 psig 3000 0 psig to 3,000 psig 15A 0 psia to 15 psia
30/15 -30 inHg to 15 psig 5 0 psig to 5 psig 300 0 psig to 300 psig 4000 0 psig to 4,000 psig 30A 0 psia to 30 psia
30/30 -30 inHg to 30 psig 10 0 psig to 10 psig 500 0 psig to 500 psig 5000 0 psig to 5,000 psig 60A 0 psia to 60 psia
30/45 -30 inHg to 45 psig 15 0 psig to 15 psig 600 0 psig to 600 psig 6000 0 psig to 6,000 psig 100A 0 psia to 100 psia
30/60 -30 inHg to 60 psig 30 0 psig to 30 psig 750 0 psig to 750 psig 7500 0 psig to 7,500 psig 150A 0 psia to 150 psia
30/100 -30 inHg to 100 psig 60 0 psig to 60 psig 1000 0 psig to 1,000 psig 10000 0 psig to 10,000 psig 200A 0 psia to 200 psia
30/150 -30 inHg to 150 psig 100 0 psig to 100 psig 1500 0 psig to 1,500 psig 15000 0 psig to 15,000 psig 300A 0 psia to 300 psia
30/200 -30 inHg to 200 psig 150 0 psig to 150 psig 2000 0 psig to 2,000 psig        
psig = gauge pressure      psia = absolute pressure      Other ranges available on special request
ACCURACIES 1 ±0.5 % full scale (BFSL)   2 ±0.25 % full scale (BFSL)      
OUTPUT SIGNALS 2 0 Vdc to 5 Vdc, 3-wire   4 1 Vdc to 6 Vdc, 3-wire   6 1 Vdc to 11 Vdc, 3-wire
3 1 Vdc to 5 Vdc, 3-wire   5 0 Vdc to 10 Vdc, 3-wire      
PROCESS
CONNECTIONS
1 1/8″ NPT Male 3 SAE J1926-3:7/16-20 9 SAE J1926-1:7/16-20
2 1/4″ NPT Male 4 1/8″ NPT Female     10 G 1/4 Male    
ELECTRICAL
CONNECTIONS
1 36" cable (connected to option 7) 6 1/2″NPT conduit (with 36″cable) 25 M12 x 1 (4-pin)
2 4-pin Bendix 7 Mini-Hirschmann (DIN EN 175301-803 Form C) 36 18" integral cable
3 6-pin Bendix        
  NOTE: 0 Vdc to 5 Vdc and 0 Vdc to 10 Vdc outputs are also available in 4-wire configurations for use with other electrical systems.