Noshok 100 Series Current Output Pressure Transmitters
SPECIFICATIONS | |
Output signal | 4 mA to 20 mA, 2-wire |
Pressure ranges | Standard gauge ranges from vacuum to 15,000 psi; Standard absolute ranges from 15 psia to 300 psia |
Proof pressure | 3 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi 1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 1.5 times full scale for 0 to 15,000 psi range |
Burst pressure | 3.8 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi 4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 3 times full scale for 0 to 15,000 psi range |
Accuracy | ± 0.5 % full scale (BFSL);optional ± 0.25% full scale (BFSL) (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
Repeatability | ≤ ± 0.05% full scale |
Hysteresis | ≤ ± 0.1% full scale |
Stability | ≤ ± 0.2% full scale for 1 year, non-accumulating |
Response time | ≤1 ms (between 10% and 90% full scale) |
Power supply* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire) |
Load limitations | ≤ (Vpower supply - 10)/.020 Amp |
Wetted materials | 316 stainless steel for vacuum through 300 psi; 17-4PH stainless steel sensing diaphragm and 316 stainless steel process connection for higher ranges |
Housing materials | 316 stainless steel |
Adjustment | ≤ ± 10% full scale for zero and span |
Pressure cycle limit | 150 Hz |
Durability | > 100,000,000 full scale cycles |
Temperature ranges | Compensated 32 °F to 176 °F (0 °C to 80 °C) Effect ± 0.017% full scale/°F for zero and span Ambient -40 °F to 185 °F (-40 °C to 85 °C) Media -22 °F to 212 °F (-30 °C to 100 °C) Storage -40 °F to 212 °F (-40 °C to 100 °C) |
Environmental rating | IP65, NEMA 4X according to EN 60529/IEC 529 |
Electromagnetic rating | CE compliant to EMC norm EN 61326:1997/A1:1998 RFI, EMI and ESD protection |
Electrical protection | Reverse polarity, over-voltage and short circuit protection |
Shock | 1000 g's per IEC 770 |
Vibration | 30 g's per IEC 770 |
Non-linearity | ≤ ±0.25% BFSL; optional ±0.125% BFSL |
Weight | Approximately 3.5 oz. |
- Highly repeatable, shock resistant transmitters with excellent long-term stability
- Standard ranges from vacuum to 15,000 psi; standard absolute ranges from 15 psia to 300 psia
- Accuracy up to ±0.25% full scale (BFSL)
- Compact size, affordable price
- Advanced diffused semi-conductor and sputtered thin film sensor for maximum stability
- Welded stainless steel pressure chamber
- High alternating load resistance
- High overpressure protection
- Compatible with NOSHOK Smart System Indicators
- CE compliant to suppress RFI, EMI and ESD, combined with reverse polarity and over-voltage protection to ensure reliable performance in the most demanding applications
- Final calibration tests prior to shipment ensures 100% "out of the box" reliability
SERIES | 100 | |||||||||
PRESSURE RANGES |
30Vac | -30 inHg to 0 psig | 5 | 0 psig to 5 psig | 200 | 0 psig to 200 psig | 3000 | 0 psig to 3000 psig | 15A | 0 psia to 15 psia |
30/15 | -30 inHg to 15 psig | 10 | 0 psig to 10 psig | 300 | 0 psig to 300 psig | 4000 | 0 psig to 4000 psig | 30A | 0 psia to 30 psia | |
30/30 | -30 inHg to 30 psig | 15 | 0 psig to 15 psig | 500 | 0 psig to 500 psig | 5000 | 0 psig to 5000 psig | 60A | 0 psia to 60 psia | |
30/45 | -30 inHg to 45 psig | 25 | 0 psig to 25 psig | 600 | 0 psig to 600 psig | 6000 | 0 psig to 6000 psig | 100A | 0 psia to 100 psia | |
30/100 | -30 inHg to 100 psig | 30 | 0 psig to 30 psig | 750 | 0 psig to 750 psig | 7500 | 0 psig to 7500 psig | 150A | 0 psia to 150 psia | |
30/150 | -30 inHg to 150 psig | 60 | 0 psig to 60 psig | 1000 | 0 psig to 1000 psig | 10000 | 0 psig to 10000 psig | 200A | 0 psia to 200 psia | |
30/200 | -30 inHg to 200 psig | 100 | 0 psig to 100 psig | 1500 | 0 psig to 1500 psig | 15000 | 0 psig to 15000 psig | 300A | 0 psia to 300 psia | |
30/300 | -30 inHg to 300 psig | 150 | 0 psig to 150 psig | 2000 | 0 psig to 2000 psig | |||||
psig = gauge pressure psia = absolute pressure Other ranges available on special request | ||||||||||
ACCURACIES | 1 | ±0.5 % full scale (BFSL) | 2 | ±0.25 % full scale (BFSL) | ||||||
OUTPUT SIGNAL | 1 | 4 mA to 20 mA, 2-wire | ||||||||
PROCESS CONNECTIONS |
1 | 1/8″ NPT Male | 3 | SAE J1926-3:7/16-20 Adjustable | 9 | SAE J1926-1:7/16-20 | ||||
2 | 1/4" NPT | 4 | 1/8" NPT Female | 10 | G1/4 Male | |||||
ELECTRICAL CONNECTIONS |
1 | 36″ cable (connected to option 7) | 6 | 1/2" NPT conduit (with 36" cable) | 25 | M12 x 1 (4-pin) | ||||
2 | 4-pin Bendix | 7 | Mini-Hirschmann (DIN EN 175301-803 Form C) | 36 | Integral cable 36″ | |||||
3 | 6-pin Bendix | |||||||||
OPTION | ORF | Threaded orifice |