Kaneko manual reset solenoid valve

Kaneko manual reset solenoid valve

In the solenoid valve is used for emergency solenoid valve and Maniaru reset operation is performed for the power outage, automatically switches the solenoid valve typically Maniaru expression Operating reset once again. or energized, even if the power failure, unless manually reset is semi-automatic valve with a mechanism that does not change the operating position.

Display: List / Grid
Show:
Sort By:
Kaneko solenoid valve manual reset M31 SERIES
M31 SERIES Feature Can be used even with a pressure differential of zero as main and pilot valves are directly connected to each other. Pressure losses are small as nominal size is equal to seat size. Products certified for high-pressure gas services are also available. Designed so that the valve after once actuated does not change its state unless it is manually reset. Precautions Install the valve with the solenoid upward with respect to horizontal piping (permissible angle of inclination is within 30 degrees to the vertical). Limited flow directions (align with the arrow indicating the flow direction). Limited flow directions (align with the arrow indicating the flow direction). Remove air through vent valve in cases where the working fluid is a liquid. Do not paint external moving parts. Standard specification FLUID GAS , LIQUID , STEAM WORKING PRESSURE See below FLUID TEMPERATURE As for working temperature you can select any KANEKO model no. that will have different inner construction. The using temperature is available form 5deg.C to 200deg.C. AMBIENT TEMPERATURE -20℃ ~ 40℃(But to be used within the range of fluid dose not f

Kaneko solenoid valve manual reset M51 SERIES
M51 SERIES Feature A kind of safety valve capable of preventing malfunctioning. Being a semi-automatic type, the valve does not operate freely like an ordinary solenoid valve by turning on or off of the power. Packed type Free from any fear of burnout or insulation degradation as the coil and movable core do not come into contact with fluid. Easy to operate manually. You can just press the palm ratchet button. We offer two types of operation and with the operation when the power during a power outage. Standard specification FLUID CLEAN AIR FLUID TEMPERATURE -20 ~ 60℃ AMBIENT TEMPERATURE -20 ~ 60℃ DUTY CYCLE 100% CONTINUOUSLY RATED OPERATING VOLTAGE RANGE +10,-15% WORKING PRESSURE 0 ~ 0.99MPa Cv. FLOW FACTOR 0.58 ELECTRICAL SPECIFICATIONS See below ELECTRICAL SPECIFICATIONS AC DC V/Hz INRUSH A HOLDING A V A   COIL INSULATION CLASS : B 100/50 2.8 0.50 24 0.91 100/60 3.1 0.56 48 0.53 110/60 2.6 0.46 100 0.24 200/50 1.4 0.25 1

Kaneko solenoid valve manual reset M81 SERIES
M81 SERIES Feature A kind of safety valve capable of preventing malfunctioning. Being a semi-automatic type, the valve does not operate freely like an ordinary solenoid valve by turning on or off of the power. Packed type Free from any fear of burnout or insulation degradation as the coil and movable core do not come into contact with fluid. Easy to operate manually. Can be latched with the push of the palm button. Available in two types ― no voltage release and electrically tripped. Standard specification FLUID CLEAN AIR FLUID TEMPERATURE -20℃~60℃ AMBIENT TEMPERATURE -20℃~60℃ DUTY CYCLE 100% CONTINUOUSLY RATED OPERATING VOLTAGE RANGE +10%,-15% WORKING PRESSURE 0 ~ 0.99MPa Cv. FLOW FACTOR 0.58 ELECTRICAL SPECIFICATIONS See below ELECTRICAL SPECIFICATIONS AC DC V/Hz INRUSH A HOLDING A V A   COIL INSULATION CLASS : B 100/50 2.8 0.50 24 0.91 100/60 3.1 0.56 48 0.53 110/60 2.6 0.46 100 0.24 200/50 1.4 0.25 110 0.26

Kaneko solenoid valves  manual reset M55 SERIES
M55 SERIES Feature A kind of safety valve capable of preventing malfunctioning. Being a semi-automatic type, the valve does not operate freely like an ordinary solenoid valve by turning on or off of the power. Constant power consumption. As a direct-acting, manual-reset type three-way valve is used as the pilot valve, power consumption is kept constant, irrespective of the valve size. Packed type Free from any fear of burnout or insulation degradation as the coil and movable core do not come into contact with fluid. Easy to operate manually. Can be latched with the push of the palm button. Available in two types ― no voltage release and electrically tripped. Standard specification FLUID CLEAN AIR FLUID TEMPERATURE -20 ~ 60℃ AMBIENT TEMPERATURE -20 ~ 60℃ DUTY CYCLE 100% CONTINUOUSLY RATED OPERATING VOLTAGE RANGE +10,-15% WORKING PRESSURE 0.12 ~ 0.99MPa Cv. FLOW FACTOR See below ELECTRICAL SPECIFICATIONS See below Cv. FLOW FACTOR NOMINAL DIAMETER 8 10 15 20 25 32 Cv. FLOW FACTOR 1.22 3.2 4.3 5.18 14.5 17.3 ELECTRICAL