Kaneko solenoid valve 4 way double
Typically, a four-way solenoid valve is used to operate the duble-acting cylinder.
Mainly, there are five pipe connecting port, four-way solenoid valve, has become a place 2 1 inlet, 2 outlet, outlet. Because it is always closed, the exhaust port is one of the four direction any functionality.
A double latch solenoid has two coils inside, it is possible to perform switching of the valve by energizing the coil in one of them. Is not that the valve is switched to form self-holding, even if the power outage after energizing time.
M15DG SERIES
Feature
Coated with hard anodized aluminum, inner sliding parts can slide very easily and work with no oil lubrication during operation, without sticking and slipping, and are excellent in wear resistance.
Compact and light since main parts are made of aluminum alloy.
AC and DC coils are easy to replace because both are contained in the same casing.
Subjected to anti-corrosion treatment with hard anodized aluminum very high in corrosion resistance.
Explosion-proof type valves certified by the Ministry of Labor.
The main valve is of a balance piston type whose switching action is done by a control piston without need for a spring. Therefore, no such malfunction as is caused by spring action will not occur even after standing for a long time.
Provided with a manual button for operation check or testing.
Reliable operation at a minimum operating pressure of 0.1 MPa because no air loss is produced.
Also available as three-way valves if three out of the five ports are selected.
Standard specification
FLUID
CLEAN AIR
FLUID TEMPERATURE
-20 ~ 60℃
AMBIENT TEMPERATURE
-20 ~ 60℃
DUTY CYCLE
100% CONTINUOUSLY RATED
OP
M65DG SERIES
Feature
Wide range of applications.
Can be used for a wider range of applications because valve sizes from 3/8″ to 1-1/4″ are available.
Manual check is possible.
Manual operation is possible. This mode can be used for operation check or switching in case of emergency.
Standard specification
FLUID
CLEAN AIR
FLUID TEMPERATURE
-20℃ ~ 60℃
AMBIENT TEMPERATURE
-20℃ ~ 60℃
DUTY CYCLE
100% CONTINUOUSLY RATED
OPERATING VOLTAGE RANGE
+10%,-15%
WORKING PRESSURE
0.1 ~ 0.9MPa
Cv. FLOW FACTOR
See below
ELECTRICAL SPECIFICATIONS
See below
Cv. FLOW FACTOR
NOMINAL DIAMETER
10
15
20
25
32
Cv. FLOW FACTOR
2.0
2.5
5.0
12.0
12.0
ELECTRICAL SPECIFICATIONS
AC
DC
V/Hz
A
V
A
GENERAL PURPOSE TYPE 12PRS,EXPLOSION-PROOF TYPE E12PRS
COIL INSULATION CLASS : B
100/50
0.052
24
0.260
100/60
0.052
48
0.120
110/60
0.058
100
0.062
200/50
0.040
110
0.067
200/60
0.040
125
0