Kaneko solenoid valve 3 way
There are three places that connection port, and the three-way solenoid valve has a valve seat in the valve in two places. Always one of the valve seat portion is open, the other valve seat is closed now.
Three-way solenoid valve, which is used to control the air for the opening and closing operation of the machine, such as single-acting cylinder or diaphragm normal operation, you can also be used to direct control of the liquid.
M00DU SERIES
Feature
Capable of preventing changes in operation by power failure.
Should power failure occur after the start of operation, the valve does not change its operating position. Therefore, accidents due to power failure can be prevented.
No loss in electric power.
Very economical since the valves are designed to reduce power consumption to about 1/3 that with our former products.
Economical and free from anxiety.
Quite safe without burnout and insulation degradation as the temperature rise of the coil is very low.
Standard specification
FLUID
CLEAN AIR
FLUID TEMPERATURE
-20~60℃
AMBIENT TEMPERATURE
-20~60℃
DUTY CYCLE
100% CONTINUOUSLY RATED
OPERATING VOLTAGE RANGE
+10,-15%
WORKING PRESSURE , Cv. FLOW FACTOR
See below
ELECTRICAL SPECIFICATIONS
See below
WORKING PRESSURE, Cv. FLOW FACTOR
ORIFICE TYPE
ORIFICE SIZE
WORKING PRESSURE
Cv. FLOW FACTOR
BLANK
1.6
0~0.99MPa
0.084
01
3.0
0~0.4MPa
0.22
ELECTRICAL SPECIFICATIONS
AC
DC
V/Hz
A
V
A
GENERAL PURPOSE TYP
M00U SERIES
Feature
Explosion-proof terminal box turns.
As the explosion-proof terminal box turns 340 degrees, conduit connections are easy to make.
Universal function.
Four modes of operation are possible, depending on the operating environment.
Long life of five million operations or more.
Compact and light.
Particularly explosion-proof type valves are very compact without parallel.
Standard specification
FLUID
CLEAN AIR
FLUID TEMPERATURE
-20~60℃
AMBIENT TEMPERATURE
-20~60℃
DUTY CYCLE
100% CONTINUOUSLY RATED
OPERATING VOLTAGE RANGE
+10,-15%
WORKING PRESSURE , Cv. FLOW FACTOR
See below
ELECTRICAL SPECIFICATIONS
See below
WORKING PRESSURE , Cv. FLOW FACTOR
ORIFICE TYPE
ORIFICE SIZE
WORKING PRESSURE
Cv. FLOW FACTOR
BLANK
1.6
0~0.7MPa
0.084
01
3.0
0~0.4MPa
0.22
STANDARD VOLTAGE
AC
DC
V/Hz
INRUSH A
HOLDING A
V
A
GENERAL PURPOSE TYPE 12PG, EXPLOSION-PROOF TYPE E12PU
COIL INSULATION CLASS:H
100/50
0.27
0.16
24
0.33
M50 SERIES
Feature
Packed type
Free from any fear of burnout or insulation degradation as the coil and movable core do not come into contact with fluid.
Safe explosion-proof construction
Explosion-proof type valves certified by the Ministry of Labor.
Highly durable
A mechanical life of five million operations or more is expectable.
Manual check is possible
Manual operation is possible. This mode can be used for operation check or switching in case of emergency.
Standard specification
FLUID
CLEAN AIR
FLUID TEMPERATURE
-20 – 60 deg.C
AMBIENT TEMPERATURE
-20 – 60 deg.C
DUTY CYCLE
100% CONTINUOUSLY RATED
OPERATING VOLTAGE RANGE
+10,-15%
WORKING PRESSURE
0 ~ 0.99MPa
Cv. FLOW FACTOR
0.18
ELECTRICAL SPECIFICATIONS
See below
STANDARD VOLTAGE
AC
DC
V/Hz
INRUSH A
HOLDING A
V
A
GENERAL PURPOSE TYPE 1 , EXPLOSION-PROOF TYPE E1
COIL INSULATION CLASS : B
100/50
2.8
0.50
24
0.91
100/60
3.1
0.56
48
0.53
110/60
2.6
0.46
100
0.24
200/50
1.4
0.2
M55 SERIES
Feature
Packed type
Free from any fear of burnout or insulation degradation as the coil and movable core do not come into contact with fluid.
Safe explosion-proof construction.
Explosion-proof type valves certified by the Ministry of Labor.
Highly durable.
A mechanical life of five million operations or more is expectable.
Manual check is possible.
Manual operation is possible.
This mode can be used for operation check or switching in case of emergency.
Standard specification
FLUID
CLEAN AIR
FLUID TEMPERATURE
-20 ~ 60℃
AMBIENT TEMPERATURE
-20 ~ 60℃
DUTY CYCLE
100% CONTINUOUSLY RATED
OPERATING VOLTAGE RANGE
+10、-15%
WORKING PRESSURE
0.12 ~ 0.99MPa
Cv. FLOW FACTOR
See below
STANDARD VOLTAGE
See below
Cv. FLOW FACTOR
NOMINAL DIAMETER
8A
10A
15A
20A
25A
32A
Cv. FLOW FACTOR
1.22
3.2
4.3
5.2
14.5
17.3
STANDARD VOLTAGE
AC
DC
V/Hz
INRUSH A
HOLDING A
V
A
GENERAL PURPOSE TYPE 1, EXPLOSION-PROOF TYPE E1
COIL INSULATION CLASS : B
Showing 1 to 4 of 4 (1 Pages)