Magnatrol standard solenoid valve
Manufacturer of a complete line of industrial solenoid valves for process control.
- 2-way, Bronze and Stainless Steel Solenoid Valves
- 1/4 inch to 3 inch pipe size and up to 500 PSIG
- Normally Closed and Normally Open configurations for quick delivery
OPERATION:
Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Pilot Valve - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N or Non Asbestos Gasket
*Orifice Seal - Buna N (Viton or Glass Filled Teflon available)
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class B, 18” leads - (Class H available) APPLICATION:
To control the flow of Water, Oil, Air, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertica
OPERATION:
Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Poppet - 303 Stainless Steel
*Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel and 302 Stainless Steel
*Body Seal - Buna N or Non Asbestos Gasket
*Orifice Seal - Buna N (Viton or Glass Filled Teflon available)
*AC Shading Coil - Copper
*Stem Pin - 304 Stainless Steel
Coil - Encapsulated Class B, 18” leads - (Class H available)
MAX. FLUID TEMP.
212°F
MAX. STATIC PRESSURE
300 PSI
Except valves listed for 500 PSI
APPLICATION:
To control the flow of Water, Oil, Air, Gas, Solvents, Brine, Vacuum an
BRONZE SOLENOID VALVE TYPE "D" FULL PORT
NORMALLY CLOSED - 3/8" TO 2" PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
OPERATION:
Valve opens when energized and closes when de-energized. In this direct acting valve the disc holder assembly is lifted from its seat by the plunger.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Disc Holder - Brass
Coil Enclosure - Malleable or Cast Iron, 1/2” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N
*Orifice Seal - Buna N (Viton or Glass Filled Teflon available)
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class B, 18” leads - (Class H available)
APPLICATION:
To control the flow of Water, Air, Gas, Solvents, Vacuum and any other fluids not reactive with construction materials and free of sediment. Buna N seating of the main orifice make the valves ideal for TIGHT SEATING, LOW PRESSURE and LOW FLOW conditions. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosur
BRONZE SOLENOID VALVE TYPE "G" FULL PORT
NORMALLY CLOSED - 1" TO 3" PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
OPERATION:
Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Pilot Valve Stem - 303 Stainless Steel
*Pilot Valve Disc Holder - Brass
*Pilot Valve Seal - Buna N (Viton available)
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N or Non Asbestos Gasket
*Orifice Seal - Buna N (Viton or Glass Filled Teflon available)
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class B, 18” leads - (Class H available)
APPLICATION:
To control the flow of Water, Air, Gas, Solvents, Vacuum and any other fluids not reactive
BRONZE SOLENOID VALVE TYPE "GR" FULL PORT
NORMALLY OPEN - 1" TO 3" PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
OPERATION:
Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Pilot Valve Stem - 303 Stainless Steel
*Pilot Valve Disc Holder - Brass
*Pilot Valve Seal - Buna N (Viton available)
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N or Non Asbestos Gasket
*Orifice Seal - Buna N (Viton or Glass Filled Teflon available)
*AC Shading Coil - Copper
*Stem Pin - 304 Stainless Steel
Coil - Encapsulated Class B, 18” leads - (Class H available)
APPLICATION:
OPERATION:
Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Pilot Valve - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Glass Filled Teflon
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class H, 18” leads
APPLICATION:
To control the flow of Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-297°F), Liquid Argon (-303°F) and Liquid Nitrogen (-320°F). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with sol
OPERATION:
Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seal it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Poppet - 303 Stainless Steel
*Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Springs - Inconel and 302 Stainless Steel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Glass Filled Teflon
*AC Shading Coil - Copper
*Stem Pin - 304 Stainless Steel
Coil - Encapsulated Class H, 18” leads
APPLICATION:
To control the flow of Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-297°F), Liquid Argon (-303°F) and Liquid Nitr
OPERATION:
Valve opens when energized and closes when de-energized. In this direct acting valve, when the coil is energized, the stem is lifted from its conical seat by the plunger.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
Coil Enclosure - Malleable Iron, 1/2” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Valve Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Metal to Metal
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class H, 18” leads
MAX. FLUID TEMP.:400°F
MAX. STATIC PRESSURE:150 PSI
DIRECT ACTING - ORIFICE SIZES 1/8” TO 1/2”
APPLICATION:
To control the flow of Steam, Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-297°F), Liquid Argon (-303°F) and Liquid Nitrogen (-320°F). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top.
Pipe
Max.
Type No.
OPERATION:
Valve closes when energized and opens when de-energized. In this direct acting valve, when the coil is energized, the stem is pressed into its conical seat by the plunger.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
Coil Enclosure - Malleable Iron, 1/2” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Poppet - 304 Stainless Steel
*Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Metal to Metal
*AC Shading Coil - Copper
*Stem Pin - 304 Stainless Steel
Coil - Encapsulated Class H, 18” leads
APPLICATION:
To control the flow of Steam, Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-297°F), Liquid Argon (-303°F) and Liquid Nitrogen (-320°F). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top.
MAX. FLUID TEMP.:400°F
MAX. STATIC PRESSURE:150 PSI
Pipe
Max.
Type No.
Watts
OPERATION:
Valve opens when energized and closes when de-energized. In this direct acting valve, when the coil is energized, the stem is lifted from its conical seat by the plunger.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
Coil Enclosure - Malleable Iron, 1/2” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Valve Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N
*Orifice Seal - Metal to Metal
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class B, 18” leads - (Class H available)
APPLICATION:
To control the flow of Water, Oil, Air, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top.
MAX. FLUID TEMP.:212°F
MAX. STATIC PRESSURE:300 PSI
Pipe
Max.
Type No.
Watts
Amps
Amps Inrush
Watts
Ship
Size
Diff.
AC
Hold
120-60
DC
Wt.
OPERATION:
Valve closes when energized and opens when de-energized. In this direct acting valve, when the coil is energized, the stem is pressed into its conical seat by the plunger.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
Coil Enclosure - Malleable Iron, 1/2” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Valve Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N
*Orifice Seal - Metal to Metal
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class B, 18” leads - (Class H available)
APPLICATION:
To control the flow of Water, Oil, Air, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top.
Pipe
Max.
Type No.
Watts
Amps
Amps Inrush
Watts
Ship
Size
Diff.
AC
Hold
120-60
DC
Wt.
Inches
PSI
120-60
&n
OPERATION:
Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Pilot Valve - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Glass Filled Teflon
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class H, 18” leads
APPLICATION:
TO CONTROL THE FLOW OF STEAM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top.
MAX. FLUID TEMP.:400°F
MAX. STATIC PRESSURE:200 PSI
Pipe
Max.
Type No.
Watts
Amps
Amps I
OPERATION:
Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron,1/2” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Poppet - 303 Stainless Steel
*Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Springs - Inconel and 302 Stainless Steel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Glass Filled Teflon
*AC Shading Coil - Copper
*Stem Pin - 304 Stainless Steel
Coil - Encapsulated Class H, 18” leads
MAX. FLUID TEMP.:400°F
MAX. STATIC PRESSURE:200 PSI
APPLICATION:
TO CONTROL THE FLOW OF STEAM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal
OPERATION:
Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it.
CONSTRUCTION:
(*Wetted parts - No Copper Bearing Alloys in contact with fluid)
*Valve Body - 304 Stainless Steel Globe Pattern - NPT ends
(For Flanged Ends go to Optional Features page)
*Piston - 303 Stainless Steel
Coil Enclosure - Malleable or Cast Iron,1/2 ” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Pilot Valve - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Glass Filled Teflon
*AC Shading Coil - Silver
*Stem Pin - Inconel
Coil - Encapsulated Class H, 18” leads
APPLICATION:
To control the flow of Corrosive Fluids, Deionized Water, Condensate, Ammonias, Vegetable Oils, Fuel Oils, Cryogenics**, Flammable Liquids. Cryogenic fluids include liquid oxygen (-297ºF), liquid argon (-303ºF) and liquid nitrogen (-320ºF). Valve operate
OPERATION:
Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop.
CONSTRUCTION:
(*Wetted parts - No Copper Bearing Alloys in contact with fluid)
*Valve Body - 304 Stainless Steel Globe Pattern - NPT ends
*Piston - 303 Stainless Steel
Coil Enclosure - Malleable or Cast Iron, 1/2 ” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Poppet - 303 Stainless Steel
*Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Glass Filled Teflon
*AC Shading Coil - Silver
*Stem Pin - 304 Stainless Steel
Coil - Encapsulated Class H, 18” leads APPLICATION:
To control the flow of Corrosive Fluids, Deionized Water, Condensate, Ammonias, Vegetable Oils, Fuel Oils, Cryogenics**, Flammable Liquids. Cryogenic fluids include liquid oxygen (-297ºF)