Invensys solenoid valve
At Invensys Appliance we design, engineer and manufacture components and systems that control the operation of kitchen and other appliances including cooking, refrigeration, laundry and dishwashing in both the commercial and residential sectors. We help our customers to delight consumers by enhancing the features of their appliances while also exceeding the energy-saving standards set by the regulating agencies and reducing the raw material content of their products.
At Invensys Appliance we work with all the top seven appliance manufacturers. Our customers include Arcelik, BSH, Candy, Haier, Samsung, Sub-Zero Wolf and Whirlpool.
Reliability - improved design and quality controls
Versatility - new solenoid design expands the range of suitable applications
Affordability - enabling product and process enhancements for Appliance OEMs
Agility - global product platform enabling Appliance OEMs to source from global Invensys locations
The new Hydra Water Valve global platform from Invensys Controls delivers the innovation, manufacturing quality and reliability you need. This single product platform offers enhanced performance: which includes a new solenoid design in a smaller package to fit in the tightest spaces and standardisation of all component geometry so a common operating package can be used globally.
Technical
Next generation solenoid provides optimal thermal efficiently with minimal footprint
Double clip coil attachment reduces assembly damage
Arc welding and spin welding manufacturing technology virtually eliminates field failures
Large bleed hole reduces risk of lockages
Wide operating voltage range withstands severe operating conditions
Slow close action reduces armature tiop wear and extends operational life
Setting the Standard
for High-Performance Design
Next
Pilot solenoid valve
Fully flexible
Approved by Major Approvals Agencies World-wide
The V1 pilot operated solenoid valve is specifically designed for the use on clothes washers, dishwashers, showers, air conditioning systems and other domestic or commercial applications.
Technical
Various inlet/outlet dimensions.
Various power supply from DC to AC.
Various connection types and dimensions, including rast 5 and rast 2.5.
Designed to provide maximum flexibility.
V1 has several options available in terms of inlet, outlet, electrical connection andpower supply.
Part of an extensive line of pilot operated solenoid valves for use in clothes
washers, dishwashers, showers, air conditioning systems and other domestic
or commercial applications.
Fully flexible and designed and produced to meet the stringent requirements
of the markets of today and the future.
Rated Voltage : 220-240 vac, 110-120 vac, 24 vac & 12 vac. Others upon request.
Rated Frequency :50-60 Hz
Power Draw : 6 Watts. (3 Watt DC servo-assisted - optional) at 230vac
Coil Insulation :Class F (140!aC Operating Temperature
Ambient Temperature : 60 !aC maximum
Liquid Temperature :90!aC maximum
Operating Cycle Rate : Tu 25!aC, Tm 90!aC & Tu 60!aC, Tm 25!aC - Continuous (100%
Tu 60!aC, Tm 90!aC - 3minutes ON, 5 minutes O
Operating Pressure Range :0.2 to 10 bar
Flow Regulator (Optional) :0.25 to 17 Litres/minute
EMC : Fully compliant
Approvals : Approved by all Major Approvals Agencies World-wide.
EN 60 730-2-8, UL 429, CSA C22.2 etc.
Insulation : Class II. Fully double insulated. No grounding required.
Terminals : Two 6.35 x 0.8 mm male tab terminals. RAST 5 and RAST 2.5 Optional.
Part of an extensive line of pilot operated solenoid valves for use in clothes
washers, dishwashers, showers, air conditioning systems and other domestic or
commercial applications.
Fully flexible and designed and produced to meet the stringent requirements of
the market of today and the future.
Rated voltage: 220-240V 50-60Hz, 110-120V 50-60Hz
12VAC & VDC; 24VAC & VDC
Power draw: 6 watt at 230V
Coil insulation: Class F (140!aC wire operating temperature)
Ambient temperature: 85!aC maximum according water temperature & duty cycle
Water temperature: 90!aC maximum according water temperature & duty cycl
Operating duty cycle: Tu 25!aC, Tm 90!aC & Tu 60!aC, Tm 25!aC, continuous (100%
(220-240V) Tu 25!aC, Tm 90!aC, 3 minutes ON, 5 minutes OF
Operating pressure range: 0.2 to 10 bar
Flow regulator (optional): 0.25 to 17 litre/minute
Fluid Drinking water
Insulation: Class II to water. No grounding required
Coil terminals: Two 6.35x0.8mm male tabs terminals, RAST5 or RAST2.5
Possible approvals: Upon request
Internal leakage Maximum 1 drop/minute on pressure range 0.2 to 10 bar
Part of an extensive line of pilot operated solenoid valves for use in clothes
washers, dishwashers, showers, air conditioning systems and other
domestic or commercial applications.
Fully flexible and designed and produced to meet the stringent
requirements of the markets of today and the future.
Rated Voltage : 220-240 vac, 110-120 vac, 24 vac & 12 vac. Others upon request.
Rated Frequency :50-60 Hz
Power Draw : 6 Watts. (3 Watt servo-assisted - optional) at 230vac
Coil Insulation :Class F (140!aC Operating Temperature
Ambient Temperature : 60 !aC maximum
Liquid Temperature :90!aC maximum
Operating Cycle Rate : Tu 25!aC, Tm 90!aC & Tu60!aC, Tm 25!aC - Continuous (100%
Tu 60!aC, Tm 90!aC - 3minutes ON, 5 minutes O
Operating Pressure Range :0.2 to 10 bar
Flow Regulator (Optional) :0.25 to 17 Litres/minute
EMC : Fully compliant
Approvals : Approved by all Major Approvals Agencies World-wide.
EN 60 730-2-8, UL 429, CSA C22.2 etc.
Insulation : Class II. Fully double insulated. No grounding required.
Terminals : Two 6.35 x 0.8 mm male tab terminals. RAST 5 and RAST 2.5 Optional.
Fully flexible
Pilot solenoid valve
One inlet two independent outlets
Suitable for multiple applications
Approved by Major Approvals Agencies World-wide
V2 pilot operated solenoid valve is specifically designed for the use on clothes washers, dishwashers, showers, air conditioning systems and other domestic or commercial applications.
It is characterised by one inlet and two independent outlets.
Technical
Various inlet/outlet dimensions.
Various power supply from DC to AC.
Various connection types and dimensions, including rast 5 and rast 2.5.
Designed to provide maximum flexibility.
V2 has several options available in terms of inlet, outlet, electrical connection and power supply.
Part of an extensive line of pilot operated solenoid valves for use in clothes
washers, dishwashers, showers, air conditioning systems and other domestic
or commercial applications.
Fully flexible and designed and produced to meet the stringent requirements
of the markets of today and the future.
Rated Voltage : 220-240 vac, 110-120 vac, 24 vac & 12 vac. Others upon request.
Rated Frequency :50-60 Hz
Power Draw : 6 Watts per coil. (3 Watt DC servo-assisted - optional) at 230vac
Coil Insulation :Class F (140!aC Operating Temperature
Ambient Temperature : 60 !aC maximum
Liquid Temperature :90!aC maximum
Operating Cycle Rate : Tu 25!aC, Tm 90!aC & Tu 60!aC, Tm 25!aC - Continuous (100%
Tu 60!aC, Tm 90!aC - 3minutes ON, 5 minutes O
Operating Pressure Range :0.2 to 10 bar
Flow Regulator (Optional) :0.25 to 17 Litres/minute
EMC : Fully compliant
Approvals : Approved by all Major Approvals Agencies World-wide.
EN 60 730-2-8, UL 429, CSA C22.2 etc.
Insulation : Class II. Fully double insulated. No grounding required.
Terminals : Four 6.35 x 0.8 mm male tab terminals. RAST 5 and RAST 2.5 Optional.
Part of an extensive line of pilot operated solenoid valves for use in clothes
washers, dishwashers, showers, air conditioning systems and other domestic
or commercial applications.
Fully flexible and designed and produced to meet the stringent requirements
of the markets of today and the future.
Rated Voltage : 220-240 vac, 110-120 vac, 24 vac & 12 vac. Others upon request.
Rated Frequency :50-60 Hz
Power Draw : 6 Watts per coil. (3 Watt DC servo-assisted - optional) at 230vac
Coil Insulation :Class F (140!aC Operating Temperature
Ambient Temperature : 60 !aC maximum
Liquid Temperature :90!aC maximum
Operating Cycle Rate : Tu 25!aC, Tm 90!aC & Tu 60!aC, Tm 25!aC - Continuous (100%
Tu 60!aC, Tm 90!aC - 3minutes ON, 5 minutes O
Operating Pressure Range :0.2 to 10 bar
Flow Regulator (Optional) :0.25 to 17 Litres/minute
EMC : Fully compliant
Approvals : Approved by all Major Approvals Agencies World-wide.
EN 60 730-2-8, UL 429, CSA C22.2 etc.
Insulation : Class II. Fully double insulated. No grounding required.
Terminals : Four 6.35 x 0.8 mm male tab terminals. RAST 5 and RAST 2.5 Optional.
Pilot solenoid valve.
Fully flexible
One inlet three and independent outlets
Suitable for multiple applications
Approved by Major Approvals Agencies World-wide
The V3 pilot operated solenoid valve is specifically designed for the use with clothes washers, dishwashers, shower, air conditioning systems and other domestic or commercial applications.
It is characterised by one inlet and three independent outlets.
Technical
Various inlet/outlet dimension.
Various power supply from DC to AC.
Various connection types and dimensions, including rast 5 and rast 2.5.
Designed to provide maximum flexibility.
V3 has several options available in terms of inlet, outlet, electrical connection and power supply.
Part of an extensive line of pilot operated solenoid valves for use in clothes
washers, dishwashers, showers, air conditioning systems and other domestic
or commercial applications.
Fully flexible and designed and produced to meet the stringent requirements
of the markets of today and the future.
Rated Voltage : 220-240 vac, 110-120 vac, 24 vac & 12 vac. Others upon request.
Rated Frequency :50-60 Hz
Power Draw : 6 Watts per coil. (3 Watt DC servo-assisted - optional) at 230vac
Coil Insulation :Class F (140!aC Operating Temperature
Ambient Temperature : 60 !aC maximum
Liquid Temperature :90!aC maximum
Operating Cycle Rate : Tu 25!aC, Tm 90!aC & Tu 60!aC, Tm 25!aC - Continuous (100%
Tu 60!aC, Tm 90!aC - 3minutes ON, 5 minutes O
Operating Pressure Range :0.2 to 10 bar
Flow Regulator (Optional) :0.25 to 17 Litres/minute
EMC : Fully compliant
Approvals : Approved by all Major Approvals Agencies World-wide.
EN 60 730-2-8, UL 429, CSA C22.2 etc.
Insulation : Class II. Fully double insulated. No grounding required.
Terminals : Four 6.35 x 0.8 mm male tab terminals. RAST 5 and RAST 2.5 Optional.
Part of an extensive line of pilot operated solenoid valves for use in clothes
washers, dishwashers, showers, air conditioning systems and other domestic
or commercial applications.
Fully flexible and designed and produced to meet the stringent requirements
of the markets of today and the future.
Rated Voltage : 220-240 vac, 110-120 vac, 24 vac & 12 vac. Others upon request.
Rated Frequency :50-60 Hz
Power Draw : 6 Watts per coil. (3 Watt DC servo-assisted - optional) at 230vac
Coil Insulation :Class F (140!aC Operating Temperature
Ambient Temperature : 60 !aC maximum
Liquid Temperature :90!aC maximum
Operating Cycle Rate : Tu 25!aC, Tm 90!aC & Tu 60!aC, Tm 25!aC - Continuous (100%
Tu 60!aC, Tm 90!aC - 3minutes ON, 5 minutes O
Operating Pressure Range :0.2 to 10 bar
Flow Regulator (Optional) :0.25 to 17 Litres/minute
EMC : Fully compliant
Approvals : Approved by all Major Approvals Agencies World-wide.
EN 60 730-2-8, UL 429, CSA C22.2 etc.
Insulation : Class II. Fully double insulated. No grounding required.
Terminals : Four 6.35 x 0.8 mm male tab terminals. RAST 5 and RAST 2.5 Optional.
Pilot operated solenoid valve
Fully flexible
One inlet and four independent outlets
Suitable for multiple applications
Approved by Major Approvals Agencies World-wide
The V4 pilot operated solenoid valve is specifically designed for use in clothes washers, dishwashers, showers, air conditioning system and other domestic or commercial applications.
It is characterised by one inlet and four independent outlets.
Technical
Various inlet/outlet dimensions.
Various power supply from DC to AC.
Various connection types and dimensions, including rast 5 and rast 2.5.
Designed to provide maximum flexibility.
V4 has several options available in terms of inlet, outlet, electrical connection and power supply.
Part of an extensive line of pilot operated solenoid valves for use in clothes
washers, dishwashers, showers, air conditioning systems and other domestic
or commercial applications.
Fully flexible and designed and produced to meet the stringent requirements
of the markets of today and the future.
Rated Voltage : 220-240 vac, 110-120 vac, 24 vac & 12 vac. Others upon request.
Rated Frequency :50-60 Hz
Power Draw : 6 Watts per coil. (3 Watt DC servo-assisted - optional) at 230vac
Coil Insulation :Class F (140!aC Operating Temperature
Ambient Temperature : 60 !aC maximum
Liquid Temperature :90!aC maximum
Operating Cycle Rate : Tu 25!aC, Tm 90!aC & Tu 60!aC, Tm 25!aC - Continuous (100%
Tu 60!aC, Tm 90!aC - 3minutes ON, 5 minutes O
Operating Pressure Range :0.2 to 10 bar
Flow Regulator (Optional) :0.25 to 17 Litres/minute
EMC : Fully compliant
Approvals : Approved by all Major Approvals Agencies World-wide.
EN 60 730-2-8, UL 429, CSA C22.2 etc.
Insulation : Class II. Fully double insulated. No grounding required.
Terminals : Four 6.35 x 0.8 mm male tab terminals. RAST 5 and RAST 2.5 Optional