Lower electric power , variety of size, and option.
New MAGSTAR solenoid valves are housing any one of the two valve types (spool and ceramic slide) as standard.
|
Compact type solenoid valve series with accumulated "proof" technologies.
Double-acting (hold type) explosion-proof solenoid valve incorporates a magnet-latched solenoid. Its compact design has been achieved by employing single conduit outlet.
Heavy duty type solenoid valve with reliable functions suitable for severe operating conditions.
Solenoid with strong suction power
Pilot valve resistant to contaminated air
Highly reliable control mechanism
Magster III series solenoid valves are for use in general industrial pneumatic systems.
Based on extensive compact design, the valves have achieved excellent saving and safety in structure and function, realizing easier operation and enhancing reliability of oilless operation.
Intrinsic safety valves can be used for applications that require similar explosion class/ignition degree to d2G4 or Exd II BT5 type (explosion-proof enclosure construction). Without need for expensive connection tools and complex installation work that are inevitable for explosion-proof enclosure types, the intrinsic safety valves achieve highly reliable explosion-proof performance.
Compact type explosion-proof solenoid valve effectively layouting a terminal box to ensure easy wiring. Connection interface can be selected from direct piping type or NAMUR standard model.
Large connection terminal enables easy wiring connection. (03 / 08 type) Highly durable, reliable performance of the solenoid valve has been achieved using oilless packing for a spool packing of the main valve. (03 type)
Employing poppet structure for both main valve and pilot valve, this product has achieved optimal resistance to drains and dusts.
Incorporated exhaust pressure protection system ensures reliable operation under any piping conditions.
Valve system is resistant to transient phenomena at switching, thus decreases air loss.
00002 597458 VALVE,SOLENOID,3-PORT,2 POSITION.KONAN
2 each
Manufacturer: KONAN
Manufacturer Part No: MVW7115AWYAC110TB115A
VALVE,SOLENOID,3-PORT,2 POSITION,110VAC,60HZ,15A PORT SIZE.
C/W MANUAL PUSH BUTTON.MFG KONAN,MVW71-15A-WY-AC110-TB1-15A,TYPE
MVW7.
KONAN MODEL :MVW7R-20A AC 240V
SOLENOID VALVE ,
50 HZ COIL 240 VAC
AIR WORKING PRESSURE 2-7 KG/CM2
Heavy duty type solenoid valve with reliable functions suitable for severe operating conditions.
Solenoid with strong suction power
Pilot valve resistant to contaminated air
Highly reliable control mechanism
Model code
Normally closed
MVW1
MVW71
MVW7
Normally open
MVW1R
MVW71R
MVW7R
Port size
Rc1/4 , Rc3/8
RC3/8
RC1/2
RC3/4
RC 1
8A , 10A
10A
15A
20A
25A
Working pressure
0~0.7MPa
MVW71:0.12~0.7MPa
MVW7:0.12~0.7MPa
MVW71R:0.2~0.7MPa
MVW7R:0.2~0.7MPa
Ambient temp.
-20~50℃
Effective area of valve
3.8mm 2
65mm 2
75mm 2
160mm 2
190mm 2
Rated voltage
AC100,110,200,220V(50/60Hz)
Heavy duty type solenoid valve with reliable functions suitable for severe operating conditions.
Solenoid with strong suction power
Pilot valve resistant to contaminated air
Highly reliable control mechanism
Model code
Closed center
MVPC1
MVPC2
Center open to exhaust
MVPO1
MVPO2
Center open to pressure
MVPE1
MVPE2
Port size
Rc3/8
Rc1/2
Rc3/4
Rc1
Rc1 1/4
Rc1 1/2
10A
15A
20A
25A
32A
40A
Working pressure
0.12~0.7MPa
Ambient temp.
-20~50℃
Effective area of valve
35mm 2
60mm 2
140mm 2
180mm 2
250mm 2
350mm 2
Rated voltage
AC100,110,200,220V(50/60Hz)
DC24,48,100,110,200,220V
Compact type explosion-proof solenoid valve effectively layouting a terminal box to ensure easy wiring. Connection interface can be selected from direct piping type or NAMUR standard model.
Model code
Return
454S101C
454S102C
454S202C
454S203C
Hold
454D101C
454D102C
454D202C
454D203C
Port size
Rc1/8
Rc1/4
Rc3/8
Effective area of valve
10mm2
22mm2
Working pressure
0.15~0.7MPa
Ambient temp.
d2G4 : -5~60℃
Exd II BT4 : -5~40℃
Solenoid
Rated voltage
AC100V,110V,200V,220V(50/60Hz) DC24V
Temperature rise
≦60℃
Insulation class
JIS C4003 Class H
Power consumption
AC: 5.5 VA (60 Hz) / 7.5 VA (50 Hz), DC: 4 W
Response time
≦0.05 sec
Explosion-proof standard
Explosion-proof enclosure construction d2G4 and Exd II BT4
5-port solenoid valve for operation change of a pneumatic actuator.
This product incorporates a bypass valve in the body and has a speed controller to adjust exhaust pressure as a standard. Valve size is designed based on the NAMUR standard.
Model code
Return
4N4S102K
Hold
4N4D102K
Port size
Rc1/4
Effective area of valve
10mm2
Working pressure
0.15~0.7MPa
Ambient temp.
d2G4 : -5~60℃
Exd II BT4 : -5~40℃
Solenoid
Rated voltage
AC100V,110V,200V,220V(50/60Hz) DC24V
Temperature rise
≦60℃
Insulation class
JIS C4003 Class H
Power consumption
AC: 5.5 VA (60 Hz) / 7.5 VA (50 Hz), DC: 4 W
Response time
≦0.05 sec
Explosion-proof standard
Explosion-proof enclosure construction d2G4 and Exd II BT4
Accessories
Bolt for mounting of TA2 rotary actuator, packings, silencer with throttle valve
Heavy duty type solenoid valve with reliable functions suitable for severe operating conditions.
Solenoid with strong suction power
Pilot valve resistant to contaminated air
Highly reliable control mechanism
Model code
Single type
MVW2
MVS2
Double type
-
MVD2
Port size
Rc1/4 , Rc3/8
Rc3/8
Rc1/2
Rc3/4
Rc1
8A , 10A
10A
15A
20A
25A
Working pressure
0.12~0.7MPa
Ambient temp.
-20~50℃
Effective area of valve
15mm 2
60mm 2
70mm 2
150mm 2
165mm 2
Rated voltage
AC100,110,200,220V(50/60Hz)
DC24,48,100,110,200,220V
Compact type solenoid valve series with accumulated "proof" technologies.
Double-acting (hold type) explosion-proof solenoid valve incorporates a magnet-latched solenoid. Its compact design has been achieved by employing single conduit outlet.
Return
Hold
Return
Hold
Model code
Drip-Proof type
MVS301K-02
MVD301K-02
MVS311K-02
MVD311K-02
Explosion-Proof type
Pressure-resistant packing system
MVS302K-02
MVD302K-02
MVS312K-02
MVD312K-02
Metal conduit system
MVS303K-02
MVD303K-02
MVS313K-02
MVD313K-02
Structure of the main valve
Direct-acting poppet valve
Port size
Rc1/4
Effective area of valve
1mm2(0.05)
4mm2(0.2)
Working pressure
0~0.7MPa
0~0.1MPa
Ambient temp.
-20~60℃
Explosion-proof standard
d2G4
Return
Hold
Model code
Drip-Proof type
MVS811K-02
MVS801K-03
MVD811K-02
MVD801K-03
Explosion-Proof type
Pressure-resistant packing system
MVS812K-02
MVS802K-03
MVD812K-02
MVD802K-03
Metal conduit system
MVS813K-02
MVS803K-03
MVD813K-02
MVD803K-03
Structure of the main valve
Ceramic slide valve Pilot-acting
Port size
Rc1/4
Rc3/8
Rc3/8
Rc1/2
Rc1/4
Rc3/8
Rc3/8
Rc1/2
Effective area of valve
16mm2
(0.9)
18mm2
(1.0)
55mm2
(3.0)
60mm2
(3.3)
16mm2
(0.9)
18mm2
(1.0)
55mm2
(3.0)
60mm2
(3.3)
Working pressure
0.12~0.7MPa
Ambient temp.
-20~60℃
Explosion-proof standard
d2G4
Return
Hold
Return
Hold
Model code
Pressure-resistant packing system
453S202C-E2K
453S203C-E2K
453D202C-E2K
453D203C-E2K
453S403C-E2K
453S404C-E2K
453D403C-E2K
453D404C-E2K
Metal conduit system
453S202C-E1K
453S203C-E1K
453D202C-E1K
453D203C-E1K
453S403C-E1K
453S404C-E1K
453D403C-E1K
453D404C-E1K
Structure of the main valve
Pilot-acting spool valve
Port size
Rc1/4
Rc3/8
Rc1/4
Rc3/8
Rc3/8
Rc1/2
Rc3/8
Rc1/2
Effective area of valve
22mm2(1.2)
40mm2(2.2)
Working pressure
0.2~0.7MPa
Ambient temp.
-5~50℃
Explosion-proof standard
d2G4
Closed center
Center open to pressure
Center open to exhaust
Closed center
Center open to pressure
Center open to exhaust
Model code
Drip-Proof type
MVPCF-03-E3K
MVPEF-03-E3K
MVPOF-03-E3K
MVPCN-08-E3K
MVPEN-08-E3K
MVPON-08-E3K
Explosion-Proof type
Pressure-resistant packing system
MVPCF-03-E2K
MVPEF-03-E2K
MVPOF-03-E2K
MVPCN-08-E2K
MVPEN-08-E2K
MVPON-08-E2K
Metal conduit system
MVPCF-03-E1K
MVPEF-03-E1K
MVPOF-03-E1K
MVPCN-08-E1K
MVPEN-08-E1K
MVPON-08-E1K
Structure of the main valve
Pilot-acting spool valve
Port size
Rc1/4・Rc3/8・Rc1/2
Rc3/4・Rc 1
Effective area of valve
40mm2(2.2)・55mm2(3.0)・70mm2(3.8)
175mm2(9.5)・185mm2(10.0)
Working pressure
0.2~0.7MPa
0.12~0.7MPa
Ambient temp.
-5~60℃
-20~50℃
Explosion-proof standard
d2G4
Return
Hold
Return
Hold
Model code
Drip-Proof type
MVS2F-03-E3K
MVD2F-03-E3K
MVS2N-08-E3K
MVD2N-08-E3K
Explosion-Proof type
Pressure-resistant packing system
MVS2F-03-E2K
MVD2F-03-E2K
MVS2N-08-E2K
MVD2N-08-E2K
Metal conduit system
MVS2F-03-E1K
MVD2F-03-E1K
MVS2N-08-E1K
MVD2N-08-E1K
Structure of the main valve
Pilot-acting spool valve
Port size
Rc1/4・Rc3/8・Rc1/2
Rc3/4・Rc 1
Effective area of valve
40mm2(2.2)・55mm2(3.0)・70mm2(3.8)
175mm2(9.5)・185mm2(10.0)
Working pressure
0.2~0.7MPa
0.12~0.7MPa
Ambient temp.
-5~60℃
-20~50℃
Explosion-proof standard
d2G4
Return
Kind of barrier to combine
i2G4
MTL728+
414S302C-Yi
414S303C-Yi
414S603C-Yi
414S604C-Yi
416S302C-Yi
416S303C-Yi
416S603C-Yi
416S604C-Yi
ExiaⅡBT5
SAF3-5
414S302M-Yi
414S303M-Yi
414S603M-Yi
414S604M-Yi
416S302M-Yi
416S303M-Yi
416S603M-Yi
416S604M-Yi
In the case of other explosion-proof barriers and combination *1
Structure of the main valve
Pilot spool type
Pilot ceramic slide type
Port size
Rc1/4
Rc3/8
Rc1/2
Rc1/4
Rc3/8
Rc1/2
Effective area of valve
25mm2
30mm2
51mm2
60mm2
24mm2
28mm2
51mm2
60mm2
Working pressure
0.2~0.7MPa
0.12~0.7MPa
Ambient temp.
-5~50℃
-10~60℃
Explosion-proof standard
Intrinsic safety construction
Operating condition
1. Use with specified safety barrier.
For i2G4 explosion-proof valves, use them with MTL728+ safety barrier.
For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that m
Intrinsic safety valves can be used for applications that require similar explosion class/ignition degree to d2G4 or Exd II BT5 type (explosion-proof enclosure construction). Without need for expensive connection tools and complex installation work that are inevitable for explosion-proof enclosure types, the intrinsic safety valves achieve highly reliable explosion-proof performance.
Return
Hold
Kind of barrier to combine
i2G4
MTL728+
454S202C-Yi
454S203C-Yi
454S403C-Yi
454S404C-Yi
454D202C-Yi
454D203C-Yi
454D403C-Yi
454D404C-Yi
ExiaⅡBT5
SAF3-5
454S202M-Yi
454S203M-Yi
454S403M-Yi
454S404M-Yi
454D202M-Yi
454D203M-Yi
454D403M-Yi
454D404M-Yi
In the case of other explosion-proof barriers and combination *1
Structure of the main valve
Pilot spool type
Port size
Rc1/4
Rc3/8
Rc1/2
Rc1/4
Rc3/8
Rc1/2
Eff
Return
Kind of barrier to combine
ExiaⅡBT5
SAF3-5
414S302M-YAi
414S303M-YAi
414S603M-YAi
414S604M-YAi
416S302M-YAi
416S303M-YAi
416S603M-YAi
416S604M-YAi
In the case of other explosion-proof barriers and combination *1
Structure of the main valve
Pilot spool type
Pilot ceramic slide type
Port size
Rc1/4
Rc3/8
Rc1/2
Rc1/4
Rc3/8
Rc1/2
Effective area of valve
25mm2
30mm2
51mm2
60mm2
24mm2
28mm2
51mm2
60mm2
Working pressure
0.2~0.7MPa
0.12~0.7MPa
Ambient temp.
-5~50℃
-10~60℃
Explosion-proof standard
Intrinsic safety construction
Operating condition
1. Use with specified safety barrier.
For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the
cond
Intrinsic safety explosion barrier is an explosion-proof device with single channel, Zener-diode DC circuit that enables interactive electric signaling without short circuit while controlling energy transmission in order to prevent ignition in explosive atmosphere.
1.Applicable to Zone 0.
2.A-class ground is not necessary since the input and output are insulated
each other.
3.When serially connected to a transmission circuit, the barrier protects
the circuit and components in hazardous area from being affected by
a serious accident in the non-hazardous area.
4.Despite in the hazardous location, conventional wiring is available.
5.Intrinsical proof of operational signal is figured out easily and at lower
cost.
6.SAF100-5 safety barrier employ crimping terminal wiring method.
7.As SAF100-5 safety barrier has protection circuit, it will be not broken
if you wired in the wrong polarity.
8.LED indicates the condition of the input and output
Model code
SAF100-5
Explosion-proof construction
Intrinsic safety construction(ExiaⅡC)
Rated voltage
Intrinsic safety explosion barrier is an explosion-proof device with single channel, shunt-diode DC circuit that enables interactive electric signaling without short circuit while controlling energy transmission in order to prevent ignition in explosive atmosphere.
1.Applicable to Zone 0.
2.When serially connected to a transmission circuit, the barrier protects
the circuit and components in hazardous area from being affected by
a serious accident in the non-hazardous area.
3.Despite in the hazardous location, conventional wiring is available.
4.Intrinsical proof of operational signal is figured out easily and at lower
cost.
5.As SAF3-5 safety barrier has protection circuit, it will be not broken
if you wired in the wrong polarity.
6.SAF3-5 safety barrier employ crimping terminal wiring method.
Model code
SAF3-5
MTL728+
Explosion-proof construction
Intrinsic safety construction(ExiaⅡB)
Intrinsic safety construction(i2G4)
Rated voltage
DC24V±5%
-
Max. working voltage
-
DC25.5V
Max. allowable voltage
-
DC26