actuator air Cylinder Solenoid Valve Transmitter SMC Parker Festo Schrader Miller Bosch Rexroth CKD Knorr Milwaukee Vickers Taiyo Numatics Mosier Allen Humphrey Koganei
Categories

Buschjost solenoid valve without differential pressure Norgren solenoid valve Series 83040

2/2-way valves DN 15 to DN 50
For neutral gases and liquid fluids
Solenoid actuated, with forced lifting
Diaphragm valves
Flange connection, pressure rating PN 16
Operating pressure 0 to 10 / 16 bar
Description (standard valve)
Solenoid valve for e. g. air, water, oil
Switching function:  normally closed
Flow direction:  determined
Fluid temperature:  ¨C10 !aC up to max. +90
Ambient temperature:  ¨C10 !aC up to max. +50
Mounting position:  optional, preferably solenoid
vertical on top
Material
Body:  Cast steel, Brass
Seal seat:  NBR
Internal parts:  Stainless steel, PVDF, Brass
For contaminated fluids insertion of a strainer is recommended.
FeaturesHigh flow rateFor robust industry solutionsDamped operationSuitable for vacuumValve operates without differential pressureSolenoid interchangeable without tools (c)Fluids of Group 2 acc. Pressure Equipment Directive 97/23/EC

Characteristic Data
Valves
Part Number Part Number Nominal Diameter Operating Pressure * k -value **
Weight Total
v
3
Solenoid with 1 Solenoid with 2 (mm) min. (bar)                      max. (bar) (Base m
/h) (kg)
8304200.9151 8304200.9154 15 0 10 3.4 1.9
8304200.8301 8304200.8304 15 0 16 3.4 2.4
8304300.9151 8304300.9154 20 0 10 5.8 2.5
8304300.8301 8304300.8304 20 0 16 5.8 3.0
8304400.9151 8304400.9154 25 0 10 8.0 3.0
8304400.8301 8304400.8304 25 0 16 8.0 3.5
8304500.9401 8304500.9404 32 0 16 23.0 6.7
8304600.9401 8304600.9404 40 0 16 25.0 7.4
8304700.9401 8304700.9404 50 0 16 41.0 10.0
2
*  for gases and liquid fluids up to 25 mm /s (cSt) State voltage [V] and frequency [Hz]
**  C -value (US) !O  -value x 1.2
v v
Solenoid 9101 / 9154; 9401 / 9404; 8301 / 8304;  Power Consumption
According to DIN VDE 0580 at coil temperature +20 !aC.
8401 / 8404
In operation the power consumption of the solenoid  
Standard voltages
decreases by approx. 30 %.
DC 1 AC 2
AC 2
40 Hz ¨C 60 H
Solenoid DC 1
Inrush Holding
24 V 24 V
9151 * 18 W  ¨  ¨
¨ 110 V
9154 *  ¨ 20 VA 20 VA
¨ 120 V
9401 * 38 W  ¨  ¨
¨ 230 V
9404 *  ¨ 42 VA 42 VA
Design acc. to DIN VDE 0580
8301 22 W  ¨  ¨
Voltage range !à10
8304  ¨ 25 VA 25 VA
100 % duty cycle
Protection class acc. to EN 60529 IP65
8401 40 W  ¨  ¨
Socket Form A acc. to DIN EN 175301-803 (included)
8404  ¨ 45 VA 45 VA
AC with rectifier plug

Part Number L H ? F max.  ? B
Diameter
(mm) (mm) (mm) (mm
mm
8304200.915x 15 130 97 96 44
8304300.915x 20 150 105 110 50
8304400.915x 25 160 108 115 62

Part Number L H ? F max.  ? B
Diameter
(mm) (mm) (mm) (mm)
mm
8304200.830x 15 130 157.5 77 44
A
P
8304300.830x 20 150 170.0 87 50
 F max.
DN
8304400.830x 25 160 175.0 90 62