actuator air Cylinder Solenoid Valve Transmitter SMC Parker Festo Schrader Miller Bosch Rexroth CKD Knorr Milwaukee Vickers Taiyo Numatics Mosier Allen Humphrey Koganei
Categories

Buschjost solenoid valve without differential pressure Norgren solenoid valve Series 86710/86700

Valve operates without differential pressure
Valve with PTFE piston guide rings
Suitable for vacuum
Technical features
Medium:  Flow direction: Fluid temperature: Materials:
Air, water and oil Determined ¨C20 ... +90! Body: Brass (CW617N)
Switching function: Port size: Ambient temperature: Seat seal: NBR
Normally closed G1/4, G3/8, G1/2, G3/4, G1,   ¨C20 ... +50!  Internal parts:  
Operation: G1 1/4, G1 1/2, G2  Stainless steel, PTFE/Carbon
Solenoid actuated,  1/4 NPT, 3/8 NPT, 1/2 NPT,
with forced lifting 3/4 NPT, 1 NPT, 1 1/4 NPT,  For contaminated luids the use
Mounting position: 1 1/2 NPT, 2 NPT  of a strainer upstream of the
Optional,   Operating pressure: valve is recommended.
preferably solenoid   0 !… 25 ba
vertical on top (0 ... 40 bar)
 
 
Technical data - standard models
Operating pressure  Weight Model Model
Symbol Port size Oriice Flow kv value *1)    
3
/h) *2) (bar) (kg) Solenoid in V d.c. Solenoid in V a.c.
(mm) (m
G1/4 8 2,2 0 ... 25 1,5 8670000.8301.xxxxx 8670000.8304.xxxxx
1/4 NPT 8 2,2 0 ... 25 1,5 8671000.8301.xxxxx 8671000.8304.xxxxx
G3/8 10 3,4 0 ... 25 1,5 8670100.8301.xxxxx 8670100.8304.xxxxx
3/8 NPT 10 3,4 0 ... 25 1,5 8671100.8301.xxxxx 8671100.8304.xxxxx
G1/2 12 4,4 0 ... 25 1,6 8670200.8301.xxxxx 8670200.8304.xxxxx
1/2 NPT 12 4,4 0 ... 25 1,6 8671200.8301.xxxxx 8671200.8304.xxxxx
G3/4 20 6,5 0 ... 25 1,8 8670300.8301.xxxxx 8670300.8304.xxxxx
A
3/4 NPT 20 6,5 0 ... 25 1,8 8671300.8301.xxxxx 8671300.8304.xxxxx
G1 25 10 0 ... 25 2,2 8670400.8301.xxxxx 8670400.8304.xxxxx
P
1 NPT 25 10 0 ... 25 2,2 8671400.8301.xxxxx 8671400.8304.xxxxx
G1 1/4 32 24 0 ... 25 5,6 8670500.8401.xxxxx 8670500.8404.xxxxx
1 1/4 NPT 32 24 0 ... 25 5,6 8671500.8401.xxxxx 8671500.8404.xxxxx
G1 1/2 40 25 0 ... 25 5,4 8670600.8401.xxxxx 8670600.8404.xxxxx
1 1/2 NPT 40 25 0 ... 25 5,4 8671600.8401.xxxxx 8671600.8404.xxxxx
G2 50 41 0 ... 25 6,8 8670700.8401.xxxxx 8670700.8404.xxxxx
2 NPT 50 41 0 ... 25 6,8 8671700.8401.xxxxx 8671700.8404.xxxxx

Option selector 867¨B¨B.¨B¨B¨B¨B.¨
Thread form Substitute
Frequency Substitute
ISO G
0
See table frequency codes
xx
NPT
1
Voltage Substitute
See Voltage  codes
Port size Substitute
xxx
1/4
0
Solenoid options Substitute
 
3/8
G1/4 ... 1
8301
1
Solenoid in V d.c.
1/2
2
 
G1 1/4 ... 2
8401
3/4
3
Solenoid in V d.c.
1
4
 
G1/4 ... 1
8304
1 1/4
5
Solenoid in V a.c.
1 1/2
6
 
G1 1/4 ... 2
8404
Solenoid in V a.c.
2
7
Valve options Substitute
Normally open (NO),
01
 
Mounting position
vertical on top
 
Manual override
02
with solenoid 8400
Seat seal FPM,
03
 
Fluid temperature
¨C10 ... +110zaC *
 
Seat seal PTFE, max.
06
Fluid temperature +110zaC *1),
G1/4 ... G1 with solenoid 8300
operatng pressure 25 bar
G1 1/4 ... G2 with solenoid 8400
operating pressure 30 bar
Seat seal EPDM,
14
max. Fluid temperature 110za
 
Normally open (NO),
17
Seat seal FPM,
 
Fluid temperature
 ¨C10 ... 110zaC *1), Mountin
position vertical on top
max. operating pressure 40
22
bar, with solenoid 8400
 
Position indicator,
23
with solenoid 8400
Seat seal FPM, with larger
25
bleed oriices in the piston, for
luids such as fuel and oil ,
2
/s (cSt),
viscosity max. 80 mm
 
Fluid temperature
¨C10 ... +110zaC *1
with solenoid 8400
Standard solenoid systems Electrical details for all solenoid systems
Design DIN VDE 0580
Voltage and Frequency Solenoid 8301/8304
Voltage range zà10
Code Code Voltage Frequency Power consumption
Voltage Frequency
Duty cycle 100% ED
Inrush Holding
024 00 24 V d.c. - 22 W 22 W
Protection class EN 60529 IP65
024 49 24 V a.c. *3) 40 zv 60 H 25 VA 25 VA
Socket Form A acc. to DIN EN 175301-803 (included)
110 49 110 V a.c. *3) 40 zv 60 H 25 VA 25 VA
According to DIN VDE 0580 at a solenoid temperature of +20!aC.
At operating state temperature the input power of a coil decreases by up to  
120 49 120 V a.c. *3) 40 zv 60 H 25 VA 25 VA
ca. 30% due to physical reasons.
230 49 230 V a.c. *3) 40 zv 60 H 25 VA 25 VA
Voltage and Frequency Solenoid 8401/8404
024 00 24 V d.c. - 40 W 40 W
x
024 49 24 V a.c. *3) 40 zv 60 H 45 VA 45 VA
Additional solenoid systems
110 49 110 V a.c. *3) 40 zv 60 H 45 VA 45 VA
ATEX category Protection class Solenoid Standard voltages
120 49 120 V a.c. *3) 40 zv 60 H 45 VA 45 VA
II2GD EEx me II T3 T 140za 8441 24 V d.c., 110 V a.c., 230 V a.c.
230 49 230 V a.c. *3) 40 zv 60 H 45 VA 45 VA
II3GD Ex nA II T4 T 135zaC *2 8326 24 V d.c., 110 V a.c., 230 V a.c.
*3) a.c. with rectiier plug
II3GD Ex nA II T4 T 135zaC *2 8426 24 V d.c., 110 V a.c., 230 V a.c.

Port size R ? A H H1 L L1 T Model
G1/4 44 143 132 60 27,5 12 8670000.830x.xxxxx
1/4 NPT 44 143 132 60 27,5 10 8671000.830x.xxxxx
G3/8 44 143 132 60 27,5 12 8670100.830x.xxxxx
3/8 NPT 44 143 132 60 27,5 10,5 8671100.830x.xxxxx
G1/2 44 145 132 67 31 14 8670200.830x.xxxxx
1/2 NPT 44 145 132 67 31 13,5 8671200.830x.xxxxx
G3/4 50 154 137 80 35,5 16 8670300.830x.xxxxx
3/4 NPT 50 154 137 80 35,5 14 8671300.830x.xxxxx
G1 62 164 143,5 95 44 18 8670400.830x.xxxxx
1 NPT 62 164 143,5 95 44 17 8671400.830x.xxxxx
G 1 1/4 92 212,5 183,5 132 60 20 8670500.840x.xxxxx
1 1/4 NPT 92 212,5 183,5 132 60 17 8671500.840x.xxxxx
G1 1/2 92 212,5 183,5 132 60 22 8670600.840x.xxxxx
1 1/2 NPT 92 212,5 183,5 132 60 17 8671600.840x.xxxxx
G2 109 212,5 183,5 160 74 24 8670700.840x.xxxxx
2 NPT 109 212,5 183,5 160 74 17,5 8671700.840x.xxxxx

Write a review

Your Name:


Your Review: Note: HTML is not translated!

Rating: Bad           Good

Enter the code in the box below:



Export Company Export Company Export Company Global Trade Leads - Import & Export on our award-winning International Trade Site