actuator air Cylinder Solenoid Valve Transmitter SMC Parker Festo Schrader Miller Bosch Rexroth CKD Knorr Milwaukee Vickers Taiyo Numatics Mosier Allen Humphrey Koganei
Categories

Part-turn actuators

Part-turn actuators

Electric part-turn actuators by AUMA are used where an automatic, electrically operated movement at a swing angle of less than 360 ° has to be implemented as it is the case for valves like butterfly and ball valves.

The proven SG .1 type range will be replaced by generation SQ .2 (currently only available with 3-phase AC motor).

The SGC/R series with integrated controls provides the customer with a multitude of possibilities to integrate actuators into a DCS. The adaptation to the requirements of nearly every valve automation task is possible.

Display: List / Grid
Show:
Sort By:
Auma Part-turn actuators SG 05.1 - SG 12.1
Part-turn actuators SG .1 for open-close duty are rated for short-time duty S2 - 15 min. A special version with reduced torque is available for the S2 - 30 min duty. The actuators can be combined with different controls from the simple OPEN-CLOSE controls to the micro-controlled version with logging of operating data or fieldbus interface. Design features: Torque range from 100 Nm to 1,200 Nm Swing angles from 80° to 110° Operating times for 90 Â° from 4 s to 70 s Limit and torque seating 3-ph AC, 1-ph AC and DC motors Handwheel for manual operation Mechanical position indicator Ambient conditions: High enclosure protection High quality corrosion protection Wide ambient temperature ranges Options: Deviating swing angle  Intermediate position switches Switch in tandem version Remote position transmitter Magnetic limit and torque transmitter Mechanical position indicator Interfaces: Electrical connection via AUMA plug/ socket connector Cable glands in different versions Output drive types according to ISO standard 

Auma Part-turn actuators SGC 04.1 – SGC 12.1
The "small" electric part-turn actuator range with integral controls. All parameters are directly set at the actuator. The controls contain switchgears, power supply unit, interface to the DCS. The component automatically switches the actuator off, once the valve end position is reached, motor overheating is detected or a torque overload has occurred. All housing parts are made of aluminium. For this reason, the actuators are lightweight devices. The actuators are rated for short-time duty S2 - 15 min. Design features: Torque range from 25 Nm to 500 Nm Swing angles 82 ° to 98 ° Operating times for 90° from 4 s to 90 s Limit and torque seating Variable speed, brushless motor Handwheel for manual operation Ambient conditions: High enclosure protection High quality corrosion protection Wide ambient temperature ranges Options: Profibus DP interface Local controls mounted separately from the actuator

Auma Part-turn actuators SGCR 04.1 – SGCR 12.1
The "small" electric part-turn actuator range with integral controls. All parameters are directly set at the actuator. The controls contain switchgears, power supply unit, interface to the DCS. The component automatically switches the actuator off, once the valve end position is reached, motor overheating is detected or a torque overload has occurred. All housing parts are made of aluminium. For this reason, the actuators are lightweight devices. The actuators are rated for intermittent duty S4 - 40%. Design features: Torque range from 25 Nm to 500 Nm Swing angles 82 ° to 98 ° Operating times for 90° from 4 s to 90 s Limit and torque seating Variable speed, brushless motor Handwheel for manual operation Ambient conditions: High enclosure protection High quality corrosion protection Wide ambient temperature ranges Options: Profibus DP interface Local controls mounted separately from the actuator

Auma Part-turn actuators SGM 04.1 – SGM 12.1
The "small" electric part-turn actuator range with integral controls. All parameters are directly set at the actuator. The controls contain switchgears, power supply unit, interface to the DCS. The component automatically switches the actuator off, once the valve end position is reached, motor overheating is detected or a torque overload has occurred. All housing components are made of bronze, all external screws are made of stainless steel. This ensures complete resistance against sea water even over a longer time period. The modulating actuators of the SGM range are rated for intermittent duty S4 - 40%. Design features: Torque range from 25 Nm to 500 Nm Swing angles 82 ° to 98 ° Operating times for 90° from 4 s to 90 s Limit and torque seating Variable speed, brushless motor Handwheel for manual operation Ambient conditions: High enclosure protection High quality corrosion protection Wide ambient temperature ranges Options: Profibus DP interface Local controls mounted separately from the actuator

Auma Part-turn actuators SGMR 04.1 – SGMR 12.1
The "small" electric part-turn actuator range with integral controls. All parameters are directly set at the actuator. The controls contain switchgears, power supply unit, interface to the DCS. The component automatically switches the actuator off, once the valve end position is reached, motor overheating is detected or a torque overload has occurred. All housing components are made of bronze, all external screws are made of stainless steel. This ensures complete resistance against sea water even over a longer time period. The modulating actuators of the SGMR range are rated for intermittent duty S4 - 40%. Design features: Torque range from 25 Nm to 500 Nm Swing angles 82 ° to 98 ° Operating times for 90° from 4 s to 90 s Limit and torque seating Variable speed, brushless motor Handwheel for manual operation Ambient conditions: High enclosure protection High quality corrosion protection Wide ambient temperature ranges Options: Profibus DP interface Local controls mounted separately from the actuator

Auma Part-turn actuators SGR 05.1 - SGR 12.1
Part-turn actuators SGR .1 are rated for intermittent duty S4 - 25%. Special versions are also available for S4 - 50 % and S5 - 25 %. The actuators can be combined with different  controls from the simple OPEN-CLOSE controls to the micro-controlled version with logging of operating data or fieldbus interface. Design features: Torque range from 100 Nm to 1,200 Nm Modulating torque range from 100 Nm to 400 Nm  Max. number of starts 600 c/h Swing angles from 80° to 110° Operating times for 90 Â° from 16 s to 50 s Limit and torque seating 3-ph AC motors Handwheel for manual operation Mechanical position indicator Ambient conditions: High enclosure protection High quality corrosion protection Wide ambient temperature ranges Options: Deviating swing angle  Intermediate position switches Switch in tandem version Remote position transmitter Magnetic limit and torque transmitter Mechanical position indicator Interfaces: Electrical connections via AUMA plug/ socket connector (optionally terminals)

Auma part-turn SGExC 05.1 - SGExC 12.1 with Auma ACExc 01.1
Design features: Torque range from 100 Nm to 675,000 Nm Swing angle from 80° to 110° adjustable end stops Operating times for 90° from 4 s to 780 s Limit and torque seating 3-ph AC and 1-ph AC motors self-retaining Handwheel for manual operation Ambient conditions: High enclosure protection High quality corrosion protection Wide ambient temperature ranges Options: Intermediate position switches Switches in tandem version Remote position transmitter Magnetic limit and torque transmitter Mechanical position indicator Interfaces: Electrical connection via AUMA plug/ socket connector with terminal boards (optionally plug-in terminal connection) Plug cover with thread for cable glands Output drive types according to ISO standard

Export Company Export Company Export Company Global Trade Leads - Import & Export on our award-winning International Trade Site