ASCO's 2-Way solenoid valves have one inlet and one outlet, and are used to permit and shut off fluid flow. The two types of operations are Normally Closed (NC) and Normally Open (NO). Two types of constructions apply to 2-way solenoid valves, which are direct acting and internally piloted.
With Direct acting constructions, the solenoid is energized, the core directly opens the orifice of a Normally Closed valve or closes the orifice in a Normally Open Valve. The valve will operate at pressures from 0 psi to its rated maximum.
Internally piloted constructions use line pressure to assist operation. When the coil is de-energized (on a Normally Closed Valve), the pilot orifice is closed and line pressure is applied to the top of the piston or diaphragm through the bleed orifice, closing the valve.
Learn more about ASCO's 2-way solenoid valves.
ASCO's line of 2-way solenoid valves include General Service, Hot Water/ Steam, Potable Water and Food Service, Vacuum, Cryogenic and Liquid C02, Air Operated, Proportional, Intrinsically Safe, Low Power, Isolation/ Shielded Core, Long Life / Quiet, Ammonia, Dry Air, Magnetic Latching and Medical/ Analytical. Select a product below to learn more.
Direct Acting Poppet – 1/8″-1/4″
Direct acting solenoid poppet valves are available in normally closed and normally open constructions, AC or DC operated in brass or stainless steel bodies. High flow and a variety of elastomers for a wide range of applications.
8262H001 - 120/60,110/50
8262H001 - 240/60,220/50
8262H232 - 120/60,110/50
EF 8262H014 - 120/60,110/50
8262H019 - 24/DC
8262H021 - 120/60,110/50
8262H086 - 120/60,110/50
8262H208 - 24/60
8262H220 - 120/60,110/50
EF 8262H220 V - 120/60,110/50
8262H014 - 120/60,110/50
8262H021 V - 120/60,110/50
8262H038 - 120/60,110/50
8262H202 - 240/60,220/50
8262H208 V - 120/60,110/50
8262H212 - 120/60,110/50
J KF 8262H022 - 120/60,110/50
SC 8262H208 - 120/60,110/50
8262H014 - 24/DC
8262H086 - 24/DC
8262H090 - 120/60,110/50
8262H090 - 24/DC
X8262C002 13200 - 120/60,110/50
8262H002 V - 120/60,110/50
8262H014 - 12/DC
8262H080 - 120/60,110/50
EF 8262H002 - 120/60,110/50
EF 8262H230 - 120/60,110/50
8262H006 - 120/60,110/50
8262H013 - 120/60,110/50
8262H019 - 120/60,110/50
8262H200 - 120/60,110/50
8262H208 - 24/DC
8262H230 - 120/60,110/50
826
Cryogenic – 1/8″-3/8″
Direct acting normally closed solenoid poppet valves available either AC or DC operated with brass bodies for liquid oxygen, liquid argon, and liquid nitrogen applications.
8263H240 LT - 120/60,110/50
8263H125 LT - 120/60,110/50
8263H206 LT - 120/60,110/50
EF 8263H240 LT - 110/50
EF 8263H240 LT - 220/50
EF 8263H240 LT - 120/60,110/50
EF 8263H240 LT - 24/60
EF 8263H240 LT - 120/60
EF 8263H240 LT - 240/60,220/50
EF 8263H240 LT - 240/60
EF 8263H125 LT - 120/60
EF 8263H125 LT - 220/50
EF 8263H206 LT - 110/50
EF 8263H206 LT - 220/50
8263H240 LT - 110/50
8263H240 LT - 240/60,220/50
J KF 8263H125 LT - 240/60
SC 8263H240 LT - 220/50
SC 8263H240 LT - 24/60
SD 8263H206 LT - 110/50
8263H206 LT - 110/50
8263H206 LT - 24/60
8263H240 LT - 208/60
EF 8263H206 LT - 240/60,220/50
HB 8263H206 LT - 110/50
SC 8263H125 LT - 110/50
SC 8263H125 LT - 120/60,110/50
8263H240 LT - 220/50
EF 8263H125 LT - 24/60
EF 8263H125 LT - 240/60
EF 8263H206 LT - 240/60
SC 8263H125 LT - 240/60
8263H240 LT - 480/60,440/50
EF 8263H206 LT - 120/60
J KF 8263H125 LT - 220/50
J KF 8263H125 LT - 240/
Dry Air - 1/4"- Direct acting soleonid poppet valves available in normally closed constructions with brass and stainless steel bodies.
Features
2-way normally closed operation
Pressures up to 540 psi
UL and CSA agency approvals
Suitable for low ambient environments
(-13?F standard, -40?F optional)
Construction
Valve Parts in Contact with Fluids
Body Brass Cast 304 Stainless Steel
Seals and Discs NBR
Core Tube 305 Stainless Steel
Core and Plugnut 430F Stainless Steel
Core Guide Acetel
Rider Ring PTFE
Springs Inconel 600
Shading Coil Copper Silver
NC
Electrical
Watt Rating and
Spare Coil Part No.
Power Consumption
Standard
AC General Purpose Explosionproof
Coil and
VA VA
Class of
Watts Holding Inrush AC AC
Insulation
F 10.1 25 50 238610 238614
F17.14070238610238614
Standard Voltages: 24, 120, 240, 480 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz).
Must be specified when ord
20 million cycle capability – 1/8″–1/4″
Solenoid pilot operated diaphragm valves available AC operated in normally closed and normally open constructions with brass bodies.
U S 8262C232 Q - 12/DC
U SF 8262C232 Q CSA - 12/DC
Direct Acting Poppet – 1/8", 1/4″
Direct acting normally closed and normally open solenoid poppet valves available AC operated with brass and stainless steel bodies.
EF 8262H220 V - 120/60,110/50
8262H021 V - 120/60,110/50
8262H208 V - 120/60,110/50
8262H002 V - 120/60,110/50
8262H128 V - 120/60,110/50
EF 8262H230 V - 120/60,110/50
EF 8262H148 V - 120/60,110/50
EF 8262H226 V - 120/60,110/50
8262H001 V - 480/60
8262H020 V - 240/60,220/50
8262H020 V - 480/60,440/50
8262H022 V - 480/60
8262H129 V - 208/60
8262H202 V - 120/60
EF 8262H013 V - 120/60
EF 8262H021 V - 110/50
EF 8262H128 V - 110/50
HT 8262H260 V - 120/60
SC 8262H129 VH - 220/50
SD 8262H230 V - 24/60
8262H006 V - 120/60
8262H006 V - 208/60
8262H011 V - 110/50
8262H020 V - 120/60,110/50
8262H021 V - 110/50
8262H129 V - 120/60
8262H129 VH - 120/60
8262H260 V - 120/60
8262H260 V - 240/60
EF 8262H006 V - 120/60
EF 8262H013 V - 240/60
EF 8262H020 V - 240/60,220/50
EF 8262H128 V - 120/60,110/50
OF KF 8262H006 V - 110/50
SC 8262H013 V - 120/60,110/50
SC 8262H128 V - 120/60,110/50
SC 8262H260 V - 110/50
U 8262C090 VH -
Direct Acting Poppet, – 3/8"
Direct acting solenoid poppet valves are available in normally closed and normally open constructions, AC or DC operated in brass or stainless steel bodies. Field replaceable seat/orifice design for flexibility.
8263H200 - 120/60,110/50
8263H002 - 120/60,110/50
8263H232 - 120/60,110/50
8263H206 - 120/60,110/50
8263H210 - 120/60,110/50
8263H206 LT - 120/60,110/50
8263H319 - 120/60,110/50
8263H240 LT - 120/60,110/50
8263H300 - 120/60,110/50
8263H305 - 120/60,110/50
8263H125 LT - 120/60,110/50
8263H210 - 240/60
8263H232 - 120/60
8263H118 - 110/50
8263H200 - 240/60,220/50
8263H232 - 110/50
8263H232 - 24/60
8263H331 - 208/60
8263H331 - 240/60
8263R200 - 24-99
8263H206 - 110/50
HB 8263H118 - 110/50
8263R193 - 24-99
EF 8263H240 LT - 24/60
8263H002 - 480/60,440/50
8263H002 - 480/60
8263H118 - 120/60
8263H118 - 24/60
8263H118 - 24/DC
8263H200 - 208/60
8263H206 - 24/60
8263H206 - 24/DC
8263H232 - 24/DC
EF 8263H240 LT - 240/60
HB 8263H118 - 120/60,110/50
8263H002 - 120/60
8263H200 - 220/50
Liquid CO2 – 1/8″ -
Direct acting normally closed solenoid poppet valves available either AC or DC operated with nickel plated brass bodies for liquid CO2 applications.
8264G009 - 120/60,110/50
8264G010 - 120/60,110/50
8264G009 - 110/50
8264G009 - 120/60
8264G009 - 24/60
8264G010 - 110/50
8264G010 - 120/60
8264G010 - 24/60
EF 8264G009 - 110/50
EF 8264G009 - 120/60,110/50
EF 8264G009 - 120/60
EF 8264G010 - 110/50
EF 8264G010 - 120/60,110/50
EF 8264G010 - 120/60
J KP 8264G009 - 110/50
J KP 8264G009 - 120/60
J KP 8264G009 - 120/60,110/50
OF SP 8264G009 - 110/50
OF SP 8264G009 - 120/60
OF SP 8264G009 - 120/60,110/50
OF SP 8264G010 - 110/50
OF SP 8264G010 - 120/60
OF SP 8264G010 - 120/60,110/50
SD 8264G010 - 110/50
SD 8264G010 - 120/60
SD 8264G010 - 120/60,110/50
8264D003 - 110/50
8264D003 - 120/60,110/50
8264D003 - 120/60
8264D004 - 110/50
8264D004 - 120/60,110/50
8264D004 - 120/60
8264D009 - 110/50
8264D009 - 120/60,110/50
8264D009 - 120/60
8264D009 CSA - 110/50
8264D009 CSA - 120/60,110/50
8264D009 CSA - 120/60
8264D010 - 110/50
8264D010 - 120/60,110/50
8264D010
Direct Acting – Straight Thru Design – 3/8″-3/4″
Unique self cleaning valves with straight through design ideal for high flow hot water / steam applications. Available AC operated in normally closed and normally open constructions with brass bodies.
8267G007 - 120/60
8267G011 - 120/60
8267G015 - 120/60
8267G019 - 120/60
8267G023 - 120/60
8267B007 - 110/50
8267B007 - 120/60,110/50
8267B007 - 120/60
8267B007 - 208/60
8267B007 - 220/50
8267B007 - 24/60
8267B007 - 240/60,220/50
8267B007 - 240/60
8267B007 CSA - 24/60
8267B011 - 110/50
8267B011 - 120/60,110/50
8267B011 - 120/60
8267B011 - 208/60
8267B011 - 220/50
8267B011 - 24/60
8267B011 - 240/60,220/50
8267B011 - 240/60
8267B012 - 110/50
8267B012 - 120/60,110/50
8267B012 - 120/60
8267B012 - 208/60
8267B012 - 220/50
8267B012 - 24/60
8267B012 - 240/60,220/50
8267B012 - 240/60
8267B015 - 110/50
8267B015 - 120/60,110/50
8267B015 - 120/60
8267B015 - 208/60
8267B015 - 220/50
8267B015 - 24/60
8267B015 - 240/60,220/50
8267B015 - 240/60
8267B015 CSA - 24/60
8267B016 - 110/50
8267B016 - 120/60,110/50
8267B016 - 120/60
Group Mounted Sub-Miniature Poppet - 1/8"
Direct acting, normally closed solenoid valves. Available either AC or DC operated in brass or stainless steel bodies. Small poppet valve well suited for a wide variety of Air, Water, Lt. Oil Applications.
SC 8280B002 - 120/60,110/50
SC 8280B002 - 120/60
SC 8280B002 - 220/50
SC 8280B002 - 24/60
SC 8280B002 - 240/60
SC 8280B002 - 240/60,220/50
SC 8280B002 - 12/DC
SC 8280B002 - 24/DC
U 8280B002 - 110/50
U 8280B002 - 120/60,110/50
U 8280B002 - 120/60
U 8280B002 - 220/50
U 8280B002 - 24/60
U 8280B002 - 240/60,220/50
U 8280B002 - 240/60
U 8280B002 - 12/DC
U 8280B002 - 24/DC
SC 8280B002 - 110/50
Air/Inert Gas, Water, Lt. Oil – 1/4″–1/2″
Air operated 2/2 valves available in normally closed constructions with brass bodies and PTFE seals.
Features
Unique sealing member isolates pilot air pressure
from mainline fluid
Variations in pilot air pressure do not affect
valve operation
Design provides long life handling of lubricated air
Handle fluids up to 200F (92C)
Some constructions handle steam up to 353F (177?C)
Mountable in any position
Construction
Valve Parts in Contact with Fluids
Body Brass
Seat NBR or PTFE (for steam service)
Air Operators
Connection Size: 1/8" NPT.
Actuated Displacement Volume: 0.60 cu. in. for 3-30 psi operators;
0.25 cu. in. for 30-125 psi operator
.
Media: Air
(For vacuum or other media, consult your local ASCO sales office for details.
Refer to Optional Features Section for other available manual operators.)
Important
On 3-way and 4-way valves, except for those with zero minimum operating
pressure, a Minimum Operating Pressure Differential must be maintained
between the pressure and exhaust ports. Supply and exhaust piping must be
full area, unrestricted. ASCO flow controls and similar components must be
installed
Air/Inert Gas, Water, Lt. Oil – 1/4″
Air operated 2/2 poppet valves available in normally closed and normally open constructions with brass and stainless steel bodies and NBR seals.
P262D090 -
Features
Unique sealing member isolates pilot air pressure
from mainline fluid
Variations in pilot air pressure do not affect
valve operation
Design provides long life handling of lubricated air
Handle fluids up to 200F (92C)
Some constructions handle steam up to 353F (177C)
Mountable in any position
Construction
Valve Parts in Contact with Fluids
Body Brass
Seat NBR or PTFE (for steam service)
Air Operators
Connection Size: 1/8" NPT.
Actuated Displacement Volume: 0.60 cu. in. for 3-30 psi operators;
0.25 cu. in. for 30-125 psi operator
.
Media: Air
(For vacuum or other media, consult your local ASCO sales office for details.
Refer to Optional Features Section for other available manual operators.)
Important
On 3-way and 4-way valves, except for those with zero minimum operating
pressure, a Minimum Operating Pressure Differential must be maintained
between the pressure and exhaust ports. Supply and exhaust piping must be
full area, unrestricted. ASCO flo
Direct Acting Poppet – 1/4″
Direct acting normally closed solenoid poppet valves available in brass or stainless steel bodies. High flow and a variety of elastomers for a wide range of applications.
Features
Available in 4 different coil terminations H Class coil construction
Designed solely for installation in intrinsically safe
or NIFW areas, with properly approved and sized
limiting barriers
Compatible with supervisory current applications
Mountable in any position
Enclosure Ratings
Catalog Enclosure Enclosure
Prefix Description Type Rating IP Rating
4, 4X IP66
IS 1/2" NPT Conduit
6, 6P IP67
4, 4X IP66
Aluminum Junction Box
JPIS
with 1/2" NPT Conduit
6, 6P IP67
4, 4X IP66
316L Stainless Steel Junction Box
JSIS
with 1/2" NPT Conduit
6, 6P IP67
24VDC Spare Coil Part Number
ISVT5-Pin (Male M12)NAIP20
IS
298006-002-D*
PILOT
ISSC DIN (Form A) NA IP20
ISSC, JPIS, JSIS
298008-002-*
ISVT
272401-047-*
SPECIAL SERVICE
Note: For 12VDC, 48VDC and 125VDC coil PN consult factory
Valve Construction
Valve Part
Magnetic Latching - 1/8"-3/8" - Available in normally closed constructions with brass and stainless steel bodies. Good for applications where contiuous power supply is not readily available. DC constructions only.
Features
Ideal for remote applications where continuously
powered devices can!ˉt be used, such as irrigation system
Pressures up to 2025 psi
Brass and Stainless Steel constructions
Construction
Valve Parts in Contact with Fluids
Body Brass Cast 304 Stainless Steel
Seals and Discs NBR / UR
Core Tube 305 Stainless Steel
Core and Plugnut 430F Stainless Steel
Springs Stainless Steel
Shading Coil Copper Silver
NC
Electrical
Watt Rating and
Spare Coil Part No.
Power Consumption
Standard Coil
DC General Purpose
and Class of
Watts DC
Insulation
A 33.2 230725
Standard Voltages: 6, 12, 24 VDC.Must be specified when ordering.
Other voltages available when required.
Solenoid Enclosure