actuator air Cylinder Solenoid Valve Transmitter SMC Parker Festo Schrader Miller Bosch Rexroth CKD Knorr Milwaukee Vickers Taiyo Numatics Mosier Allen Humphrey Koganei
Categories

Magnatrol standard solenoid valve

Magnatrol standard solenoid valve

Manufacturer of a complete line of industrial solenoid valves for process control.

  • 2-way, Bronze and Stainless Steel Solenoid Valves
  • 1/4 inch to 3 inch pipe size and up to 500 PSIG
  • Normally Closed and Normally Open configurations for quick delivery
Display: List / Grid
Show:
Sort By:
Magnatrol standard STAINLESS STEEL SOLENOID VALVE TYPE "W" FULL PORT
OPERATION: Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. CONSTRUCTION: (*Wetted parts - No Copper Bearing Alloys in contact with fluid) *Valve Body - 304 Stainless Steel Globe Pattern - NPT ends *Piston - 303 Stainless Steel Coil Enclosure - Malleable or Cast Iron,1/2” NPS conduit conn. *Plunger - 430 Stainless Steel *Pilot Valve - 303 Stainless Steel *Bonnet Tube - 304 Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon *AC Shading Coil - Silver *Stem Pin - Inconel Coil - Encapsulated Class H, 18” leads MAX. FLUID TEMP.:400°F MAX. STATIC PRESSURE:200 PSI APPLICATION: To control the flow of STEAM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top.

Magnatrol standard STAINLESS STEEL SOLENOID VALVE TYPE "WR" FULL PORT
OPERATION: Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. CONSTRUCTION: (*Wetted parts - No Copper Bearing Alloys in contact with fluid) *Valve Body - 304 Stainless Steel Globe Pattern - NPT ends *Piston - 303 Stainless Steel Coil Enclosure - Malleable or Cast Iron, 1/2” NPS conduit conn. *Plunger - 430 Stainless Steel *Poppet - 303 Stainless Steel *Stem - 303 Stainless Steel *Bonnet Tube - 304 Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon *AC Shading Coil - Silver *Stem Pin - 304 Stainless Steel Coil - Encapsulated Class H, 18” leads APPLICATION: To control the flow of STEAM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with

Magnatrol standard STAINLESS STEEL SOLENOID VALVES BULLETIN 3006-J
MAX. FLUID TEMP.:400!a MAX. STATIC PRESSURE:300 PSI DIRECT ACTING - ORIFICE SIZES 1/8!± TO 3/8 300 PSI 300 PSI OPERATION: Valve opens when energized and closes when de-energized.  In this direct acting valve, when the coil is energized, the stem is lifted from its conical seat by the plunger. CONSTRUCTION:  (*Wetted parts) *Valve Body - 304 Stainless Steel Globe Pattern - NPT ends Coil Enclosure - Malleable Iron,1/2 !± NPT conduit conn *Plunger - 430 Stainless Steel *Valve Stem - 303 Stainless Steel *Bonnet Tube - 304 Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Oriice Seal - Metal to Metal *AC Shading Coil - Silver *Stem Pin - Inconel Coil - Encapsulated Class H, 18!± lead APPLICATION: To control the low of Steam, Hot Liquids, Hot Gases,Cryogenics and any other luids not reactive with construction materials and free of sidement.  Cryogenic luids include liquid oxygen (-297 F), liquid argon(-303 F) FOR OPTIONS and liquid nitrogen (-320 F).  Valve operates from zero tO ACCESSORIES maximum diferential pressure indicated in table.  Valve SEE PAGES 26 & 27 must be mounted in horizontal pipe with solenoid enclos

Magnatrol standard STAINLESS STEEL SOLENOID VALVES BULLETIN 3006-JR
MAX. FLUID TEMP.:400!a MAX. STATIC PRESSURE:300 PSI DIRECT ACTING - ORIFICE SIZES 1/8!± TO 3/8 NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN OPERATION: Valve closes when energized and opens when de-energized.  In this direct acting valve, when the coil is energized, the stem is pressed into its conical seat by the plunger. CONSTRUCTION:  (*Wetted parts) *Valve Body - 304 Stainless Steel Globe Pattern - NPT ends   Coil Enclosure - Malleable Iron,1/2 !± NPT conduit conn *Plunger - 430 Stainless Steel *Poppet - 304 Stainless Steel *Stem - 303 Stainless Steel *Bonnet Tube - 304 Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Oriice Seal - Metal to Metal *AC Shading Coil - Silver *Stem Pin - Inconel Coil - Encapsulated Class H, 18!± lead APPLICATION: To control the low of Steam, Hot Liquids, Hot Gases,Cryogenics and any other luids not reactive with construction materials and free of sidement. Cryogenic luids include liquid oxygen (-297 F), liquid argon (-303 F)and liquid nitrogen (-320 F).  Valve operates from zero to FOR OPTIONS AND maximum diferential pressure indicated in table.  Valve  ACCESSORIES must be mount

Export Company Export Company Export Company Global Trade Leads - Import & Export on our award-winning International Trade Site