MAC proportional pressure control PQE and pressure control system
Series | PQE6500 info | PQE92 info |
Flow Cv | 6.3 | 1.3 |
Port Size | 1/2-3/4" | 1/4-3/8" |
Series | Proportional Multi-Pressure Pak info | Multi-Pressure Pak info |
OPERATIONALBENEFITS
1. Reliable operation, using two MAC 400 Series
with balanced pilot.
2. Fast response.
3. Long life.
4. High flow.
5. Low power consumption.
6. Not affected by vibrations.
7. Accuracy : 2.5 % full scale
8. Analog command signal and output.
GENERALDATA
Ambient temperature :32 to 120F/0 to 50
LED indicators :Red : power on - Green : pressure achieved
Vibration :Not affected
Port size :G1/4±, 1/4± NPTF - Option : bottom por
Connector :7 pin terminal block
Mounting :Any plane
ELECTRICALDATA
Supply voltage :20.4 to 26.4 VDC
Supply current :50 to 350mA
Command signal :0 to 10V or 4 to 20mA
Command type :Single-ended or differential
Input impedance :4.99 k 1.0% (voltage316 0.1% (current
Analog Monitor Signal (AMS) :0 to 10 Volt
Logic Monitor Signal (LMS) :2 types of signals (see How to order) (sinking)
EMI/RFI protection :Common mode and high frequency noise reduction for electrical inputs
PNEUMATICDATA
Inlet pressure* :120 PSI max (for 10-100 PSI output pres.),8 BAR max (for 0.66-6.6 BAR output pres.)
Fluids :Compressed air or inert gases
Lubrication :Not required. However, if used, a medium aniline point oil is recommended
Ou
OPERATIONALBENEFITS
1. Reliable operation, using two MAC 47 Series
with balanced poppet.
2. Fast response.
3. Long life.
4. High flow.
5. Low power consumption.
6. Not affected by vibrations.
7. Accurate pressure control.
8. Analog command signal and output.
GENERALDATA
Ambient temperature :32 to 120F/0 to 50
LED indicators :Red : power on - Green : pressure achieved
Enclosure :Aluminium Barstock, sealed
Vibration :Not affected
Port size :1/4± (side only
Connector :3, 5, 6 or 7 Pin Plug-in or 7 wire grommet
Mounting :Any plane
Washdown :Not available at this time
ELECTRICALDATA
Supply voltage :20.4 to 26.4 VDC
Supply current :110 to 440mA
Command signal :0 to 10V or 4 to 20mA
Command type :Single-ended or differential
Input impedance :4.99 k 1.0% (voltage316 0.1% (current
Analog Monitor Signal (AMS) :0 to 10 Volt, single-ended
Logic Monitor Signal (LMS) :2 types of signals (see How to order) (sinking)
EMI/RFI protection :Common mode and high frequency noise reduction for electrical inputs
PNEUMATICDATA
Inlet pressure* :
120 PSI max (for 10-100 PSI output pres.)
8 BAR max (for 0.66-6.6 BAR output pres.)
Fluids :Compressed air or inert gase
OPERATIONALBENEFITS
1. Reliable operation, using two MAC 92 Series
with balanced pilot.
2. Fast response.
3. Long life.
4. High flow.
5. Low power consumption.
6. Not affected by vibrations.
7. Accuracy : 2.5 % full scale
8. Analog command signal and output.
GENERALDATA
Ambient temperature :32 to 120F/0 to 50
LED indicators :Red : power on - Green : pressure achieved
Enclosure :Aluminium Barstock, sealed
Vibration :Not affected
Port size :3/8± (side only
Connector :3, 5, 6 or 7 Pin Plug-in or 7 wire grommet
Mounting :Any plane
Washdown :Standard
ELECTRICALDATA
Supply voltage :20.4 to 26.4 VDC
Supply current :50 to 350mA
Command signal :0 to 10V or 4 to 20mA
Command type :Single-ended or differential
Input impedance :4.99 k 1.0% (voltage316 0.1% (currentAnalog Monitor Signal (AMS) :0 to 10 Volt
Logic Monitor Signal (LMS) :2 types of signals (see How to order) (sinking)
EMI/RFI protection :Common mode and high frequency noise reduction for electrical inputs
PNEUMATICDATA
Inlet pressure* :120 PSI max (for 10-100 PSI output pres.),8 BAR max (for 0.66-6.6 BAR output pres.)
Fluids :Compressed air or inert gases
Lubrication :Not required. However,
OPERATIONALBENEFITS
1. Reliable operation, using two MAC 93 Series
with balanced pilot.
2. Fast response.
3. Long life.
4. High flow.
5. Low power consumption.
6. Not affected by vibrations.
7. Accuracy : 2.5 % full scale
8. Analog command signal and output.
GENERALDATA
Ambient temperature :32 to 120F/0 to 50
LED indicators :Red : power on - Green : pressure achieved
Enclosure :Aluminium Barstock, sealed
Vibration :Not affected
Port size :1/2± or 3/4± (side onl
Connector :3, 5, 6 or 7 Pin Plug-in or 7 wire grommet
Mounting :Any plane
Washdown :Standard
ELECTRICALDATA
Supply voltage :20.4 to 26.4 VDC
Supply current :50 to 275mA - 50 to 350mA
Command signal :0 to 10V or 4 to 20mA
Command type :Single-ended or differential
Input impedance :4.99 k 1.0% (voltage316 0.1% (current
Analog Monitor Signal (AMS) :0 to 10 Volt
Logic Monitor Signal (LMS) :2 types of signals (see How to order) (sinking)
EMI/RFI protection :Common mode and high frequency noise reduction for electrical inputs
PNEUMATICDATA
Inlet pressure* :120 PSI max (for 10-100 PSI output pres.),8 BAR max (for 0.66-6.6 BAR output pres.)
Fluids :Compressed air or inert gases
Lubrication