Buerkert valve Aggressive media
Restrict the typelist step by step to find the suitable types
Circuit function Function Pressure in bar (max)
2/2-way NC (A) direct-acting 2
2/2-way NO (B) servo-assisted 3
3/2-way NC (C) 4
3/2-way NO (D) 5
universal (E/F/T) 6
16
6642
p. 1/4
www.burkert.com
2/2-way Solenoid Valve,
servo-assisted
Type 6642 is a servo-assisted solenoid valve
with a servo-diaphragm and a plastic body. A
minimum differential pressure of 0.5 bar is
required for full opening and closing. The valve
can be removed from pipework.
Type 2506
Cable plug
Type 2510
ASI Cable plug
• Medium separated from the actuator system
• For aggressive fluids
• True union and threaded connection
• Can be mounted or removed radially for space-
saving installation
• Low power consumption
Technical data
Orifice
DN 10 and 13 mm
Body material
PVC
Body cap
PVC
Pilot valve flange
PEEK
Valve internal parts
PVDF
Seal material
FKM, EPDM
Media FKM
Neutral media, oxidizing acid,
salt solution, oil with additives
All kinds of fluids
which don’t attack the
materials in contact
with the media
Media EPDM
Acid to medium concentration,
alkaline media
Temperature media
FKM
EPDM
See
Pressure-temperature chart
0 to +50 °C
0 to +50 °C
Ambient temperature
0 to +40 °C
Operating voltage
24 V/DC (3.4 W)
for 24 VAC, u
2/2 and 3/2-way ipper solenoid
valve for analytical applications
Only 4.5 mm wide
Medium isolation, for aggressive fluids
Direct-acting
Vacuum up to 7 bar
Short response times
Technical data
DN 0.4 and 0.8 mm
Ori ce
PEEK
Body material
FFKM (Simriz)
Seal material
Resistant to neutral and aggressive uids and gases;
Medium
see Brkert resistance tabl
+15 to +50!
Medium temperature
+10 to +50!
Ambient temperature
approx. 30
Internal volume
Flange
Port connection
Plug Brkert type 250
Electrical connection
24V (12V on request)
Operating voltages
!10
Voltage tolerance
5.7 W
Nominal power
For 100% duty cycle power has to be reduced exter-
nally. See accessories table and operating instructions
for details.
100% continuous operation only with external power
Duty cycle
reduction
As required; with side by side connection standard
Installation
polarity is adhered to
IP65
Protection class
80Hz (for mechanical limit observe maximum temperature)
Switching frequency
15Hz (continous with external power reduction, for more
information see manual)
<5ms (acc. to ISO 12238)
Response times
Ordering chart
1