actuator air Cylinder Solenoid Valve Transmitter SMC Parker Festo Schrader Miller Bosch Rexroth CKD Knorr Milwaukee Vickers Taiyo Numatics Mosier Allen Humphrey Koganei
Categories

MAC proportional pressure control PQE and pressure control system

MAC proportional pressure control PQE and pressure control system
Series PQE6500 info PQE92 info
Flow Cv 6.3 1.3
Port Size 1/2-3/4" 1/4-3/8"
Series Proportional Multi-Pressure Pak info Multi-Pressure Pak info
Display: List / Grid
Show:
Sort By:
MAC proportional pressure control PQE and pressure control system LCP35A
OPERATIONALBENEFITS 1. Reliable operation, using two MAC 35 Series 2. Repeatability. 3. Fast response. 4. Long life. 5. High flow. 6. Low power consumption. 7. Not affected by vibrations. 8. Accurate pressure control. 9. Analog command signal and output. GENERALDATA Ambient temperature :32 to 120°,F/0 to 50° Vibration :Not affected Port size :1/8°± Connector :4 pin terminal block Mounting :Any plane ELECTRICALDATA Supply voltage :18 to 28 VDC Supply current :50 to 350mA Command signal :4 to 20mA, 0-10v Command type :Differential Input impedance :316  °0.1% (current4.99  °1.0%  (voltage EMI/RFI protection :Common mode and high frequency noise reduction PNEUMATICDATA Inlet pressure :120 PSI max (for 10-100 PSI output pressure) 8 BAR max (for 0.66-6.6 BAR output pressure) Fluids :Air or inert gases Lubrication :Not required, if used select a medium aniline point oil Output pressure : 0 to 10, 30, 40, 45, 60 and 100 0 to 0.66, 2, 2.6, 3, 4 and 6.6 Overall accuracy : 1.5% full scal 2.5% full scal Flow :Cv 0.10/100 Nl/min Minimum closed end volume :1.0 cubic inch

MAC proportional pressure control PQE and pressure control system Multi-Pressure Pak
OPERATIONALBENEFITS 1. Fast response.applications. 2. Long life. 3. High flow. 4. The use of a digital command signal brings easy installation and use. 5. A compact and lightweight unit saves room and installation costs. 6. This system is the alternative to proportional valves if more than six pressures or closed loop feedback are not required. is easy to set up and 7. The Multi-Pressure Pakmaintain. 8. For 2, 3 or 4 ported weld guns and other 9. Accuracy of °?2.5 % of full scal TECHNICALDATA Min. supply pressure :25 PSI (1.7 BAR) Max. supply pressure :150 PSI (10 BAR) Pressure output range :25-120 PSI (1.7 to 8 BAR) Voltages available    AC :120/60, 110/50 DC :12 & 24 volt. 1.8 to 12.7 watts Other AC and DC Consult factory voltages available : Air supply :40 micron filtration Lubrication :Not required but if lubrication is used, a medium aniline point oil is recommended NOTE: Pressures shown are minimum and maximum safe working pressures. *Series Port size Flow 82 1/4" - 3/8" C 0.9 / 900 Nl/Min v 93 3/8" - 1/2" C 2.4 / 2400 Nl/Min v 6300 3/8" - 1/2" C 2.1 / 2100 Nl/Min v 6500 1/2" - 3/4" C 3.5 / 3500 Nl/Min v ISO 1 1/4" - 3/8

MAC proportional pressure control PQE and pressure control system PPC036A
AMS ¨C NALOG MONITOR SIGNAL - 0-10 VDC FEEDBACKSIGNALTHATPROVIDESAVOLTAGE PROPORTIONALTOTHEOUTPUTPRESSURE LMS 1 ¨C OGIC MONITOR SIGNAL - 5 VDC  (TTL HIGH), 24 VDC (HIGH), 5 VDC (LOW),OR 24 VDC (LOW) ! GO/ NOGO! FEEDBACKSIGNAL (DEPENDINGONREQUIREMENTS) LMS 2 ¨C OGIC MONITOR SIGNAL - 5 VDC (TTL LOW), 24 VDC (HIGH),OR 24 VDC (LOW) !GO / NOGO FEEDBACKSIGNAL (DEPENDINGONREQUIREMENTS) CV+ - P OSITIVE COMMAND SIGNAL - POSITIVELEADFORTHE 0 ¨C 10 VDCOR 4-20MACOMMANDSIGNAL (DEPENDSONREQUIREMENTS) CV- - N EGATIVE COMMAND SIGNAL - NEGATIVELEADFORTHE 0 ¨C 10 VDCOR 4 ¨C20MACOMMANDSIGNAL (DEPENDSONREQUIREMENTS) C OM ¨C AIN POWER COMMON - COMMONLEADFORTHE 24 VDC POWER PWR ¨C AIN POWER - POSITIVE LEADFORTHE 24 VDC POWER

MAC proportional pressure control PQE and pressure control system PPC34B
OPERATIONALBENEFITS 1. Reliable operation, using two MAC 34 Series with balanced poppet. 2. Fast response. 3. Long life. 4. High flow. 5. Low power consumption. 6. Not affected by vibrations. 7. Accurate pressure control. 8. Analog command signal and output. GENERALDATA Ambient temperature :32 to 120°,F/0 to 50° LED indicators :Red : power on - Green : pressure achieved Vibration :Not affected Port size :G 1/8°±, 1/8°± NPT - Option : bottom por Connector :7 pin terminal block Mounting :Any plane ELECTRICALDATA Supply voltage :20.4 to 26.4 VDC Supply current :50 to 275mA Command signal :0 to 10V or 4 to 20mA Command type :Single-ended or differential Input impedance :4.99 k °1.0% (voltage316  °?0.1%  (current Analog Monitor Signal (AMS) :0 to 10 Volt Logic Monitor Signal (LMS) :2 types of signals (see How to order) (sinking) EMI/RFI protection :Common mode and high frequency noise reduction for electrical inputs PNEUMATICDATA Inlet pressure* : 120 PSI max (for 10-100 PSI output pres.) 8 BAR max (for 0.66-6.6 BAR output pres.) Fluids :Compressed air or inert gases Lubrication :Not required. However, if used, a medium aniline point oil is

MAC proportional pressure control PQE and pressure control system PPC45A
OPERATIONALBENEFITS 1. Reliable operation, using two MAC 45 Series with balanced poppet. 2. Fast response. 3. Long life. 4. High flow. 5. Low power consumption. 6. Not affected by vibrations. 7. Accurate pressure control. 8. Analog command signal and output. GENERALDATA Ambient temperature :32 to 120F/0 to 50 LED indicators :Red : power on - Green : pressure achieved Vibration :Not affected Port size :G 1/8±, 1/8± NPT - Option : bottom por Connector :7 pin terminal block Mounting :Any plane ELECTRICALDATA Supply voltage :20.4 to 26.4 VDC Supply current :50 to 350mA Command signal :0 to 10V or 4 to 20mA Command type :Single-ended or differential Input impedance :4.99 k 1.0% (voltage316  0.1% (current Analog Monitor Signal (AMS) :0 to 10 Volt Logic Monitor Signal (LMS) :2 types of signals (see How to order) (sinking) EMI/RFI protection :Common mode and high frequency noise reduction for electrical inputs PNEUMATICDATA Inlet pressure* : 120 PSI max (for 10-100 PSI output pres.) 8 BAR max (for 0.66-6.6 BAR output pres.) Fluids :Compressed air or inert gases Lubrication :Not required. However, if used, a medium aniline point oilis recommended O

MAC proportional pressure control PQE and pressure control system PPC45B
OPERATIONALBENEFITS 1. Reliable operation, using two MAC 45 Series with balanced poppet. 2. Fast response. 3. Long life. 4. High flow. 5. Low power consumption. 6. Not affected by vibrations. 7. Accurate pressure control. 8. Analog command signal and output. GENERALDATA Ambient temperature :32 to 120F/0 to 50 LED indicators :Red : power on - Green : pressure achieved Enclosure :Aluminium Barstock, sealed Vibration :Not affected Port size :1/8± (side only Connector :3, 5, 6 or 7 Pin Plug-in or 7 wire grommet Mounting :Any plane Washdown :Standard ELECTRICALDATA Supply voltage :20.4 to 26.4 VDC Supply current :50 to 350mA Command signal :0 to 10V or 4 to 20mA Command type :Single-ended or differential Input impedance :4.99 k 1.0% (voltage 316  0.1% (current Analog Monitor Signal (AMS) :0 to 10 Volt Logic Monitor Signal (LMS) :2 types of signals (see How to order) (sinking) EMI/RFI protection :Common mode and high frequency noise reduction for electrical inputs PNEUMATICDATA Inlet pressure* :120 PSI max (for 10-100 PSI output pres.),8 BAR max (for 0.66-6.6 BAR output pres.) Fluids :Compressed air or inert gases Lubrication :Not required. Howev

MAC proportional pressure control PQE and pressure control system PPC5C
OPERATIONALBENEFITS 1. Reliable operation, using two MAC 34 Series with balanced poppet. 2. Fast response. 3. Long life. 4. High flow. 5. Low power consumption. 6. Rugged enclosure. 7. Not affected by vibrations. 8. Accurate pressure control. 9. Can be stand alone or used in combination with our remote air sandwich regulators. 10. Analog command signal and output. GENERALDATA Ambient temperature :32°,F to 120°,F/0 to 50 LED indicators :Red : power on - Green : pressure achieved Enclosure :Aluminium, sealed Vibration :Not affected Port size :G 1/8°±, 1/8°± NPT - Option : bottom por Micro or mini 3, 5 or 6 pin plug-in Connector :3, 4, 5 or 6 wire grommet Mounting :Any plane Protection :IP 65 ELECTRICALDATA Supply voltage :20.4 to 26.4 VDC Supply current :50 to 275mA (single transducer), 50 to 500mA (dual transducer) Command signal :0 to 10V or 4 to 20mA Command type :Single-ended or differential Input impedance :4.99 k °1.0% (voltage, 316  °?0.1% (current Analog Monitor Signal (AMS) :0 to 10 Volts Logic Monitor Signal (LMS) :TTL or 24V 10mA max. (sinking) EMI/RFI protection :Common mode and high frequency noise reduction for electrical inputs

MAC proportional pressure control PQE and pressure control system PPCB10A
1 Type A  Analog 2 Mounting / Port Size & Type AA  Base Side Port 1/8!± NPT AB  Base Side Port 1/8!± BSPP AC  Base Side Port 1/8!± BSPT AD  Base Side 10/32 AE  Base Side Port M5 AF  Base Side M4 Tube Receptacle AG  Base Side 5/32 Tube Receptacle CA*  Base Manifold Mt. DA  DIN Rail Base 1/8!± NPTF Side Por DB  DIN Rail Base 1/8!± BSPPL Side Por DC  DIN Rail Base 1/8!± BSPTR Side Por DD  DIN Rail Base 10/32 Side Port DE  DIN Rail Base M5 Side Port DF  DIN Rail Base M4 Tube Receptacle DG  DIN Rail Base 5/32 Tube Receptacle 3 Pressure Range 0A  100 psi 0B  60 psi 0C  30 psi 0D  15 psi 0N  10 psi 0T  45 psi 0J  75psi 0L  4 psi 4 Pressure Reference G  Gage Pressure 5 Accuracy A  !à 1.5% F.S C  !à 0.5% F.S E  !à 2.5% F.S 6 Command Signal B  0 - 10v Differential D  4 - 20mA Differential 7 LMS Signal A  TTL LMS & AMS 8 Cover A  No Cover 1 Spacing 00  29.00mm Spacing A  Side Cylinder Ports 3 Style A  Standard 4 Port Size and Thread Type A  1/8!± NPT B  1

MAC proportional pressure control PQE and pressure control system PQE6500
OPERATIONOFTHEPQE 1. The pilot operated regulator and the PPC5C are both fed from a common inlet. 2. The °∞out°± port of the PPC5C sends pressure to the pilot port of the pilot operated regulator and to the °∞12°± of the 400 Series Quick Exhaust Valve. The secondary pressure of the pilot operated regulator is sent to the output port of the block and it is also sent to the °∞14°± end and inlet of the 400 Series Quick Exhaust Valv 3. The outlet pressure of the PPC5C along with the memory spring in the 400 Series valve will keep the valve in a closed state as the unit increases pressure. 4. To reduce pressure, drop the PPC5C°Os signal. This will lower the pressure on the °∞12°± end of the 400 Ser valve. The °∞14°± end of the 400 Series valve now has higher pressure causing a snap-action shifting of the 4 Series valve which will quickly exhaust the downstream pressure to the new selected pressure. PNEUMATICDATA Inlet pressure :120 PSI max Fluids :Air or inert gases Lubrication :Not required. However, if used, a medium aniline point oilis recommended Filtration :40 micron *Output pressure :20 to 100 PSI Overall accuracy :2.5% full scale All ports :1/2, 3/4, NPTF, BSPP

MAC proportional pressure control PQE and pressure control system PQE92
OPERATIONOFTHEPQE 1. The pilot operated regulator and the PPC5C are both fed from a common inlet. 2. The °∞out°± port of the PPC5C sends pressure to the pilot port of the pilot operated regulator and to the °∞12°± of the 400 Series Quick Exhaust Valve. The secondary pressure of the pilot operated regulator is sent to the output port of the block and it is also sent to the °∞14°± end and inlet of the 400 Series Quick Exhaust Valv 3. The outlet pressure of the PPC5C along with the memory spring in the 400 Series valve will keep the valve in a closed state as the unit increases pressure. 4. To reduce pressure, drop the PPC5C°Os signal. This will lower the pressure on the °∞12°± end of the 400 Ser valve. The °∞14°± end of the 400 Series valve now has higher pressure causing a snap-action shifting of the 4 Series valve which will quickly exhaust the downstream pressure to the new selected pressure. OPERATIONALBENEFITS 1. Accurate pressure control. 2. Fast response. 3. High flow. 4. Quick exhaust function. 5. Unaffected by change in line pressure. 6. Long life. 7. Designed to meet Nema 4 specifications. 8. Analog control. 9. Analog or TTL feedback. 10. Closed loop s

MAC proportional pressure control PQE and pressure control system Proportional Multi-Pressure Pak
OPERATIONALBENEFITS 1. Fast response. 8. For 2, 3 or 4 ported weld guns and other 2. Long life. applications. 3. High flow. 9. Accuracy of °?2.5 % of full scale (consult factor 4. The use of an analog or 4 bit or 8 bit command for other accuracies). signal brings increased accuracy in pressure 10. DeviceNet compatible. control. 5. A compact unit saves room and installation costs. 6. The analog and logic (TTL) outputs allow for constant pressure monitoring from the control unit. 7. Infinite or discrete number of pressures available. TECHNICALDATA Supply pressure : 2 to 10 bar/30 to 150 PSI *Output pressure : Standard : 1.7 to 10 bar, other ranges upon request. 25 to 150 PSI * For 82 and ISO 1 - 1.7 to 8 BAR, 25 to 120 PSI *Series Port size Flow 82 1/4" - 3/8" C 0.9 / 900 Nl/Min v 93 3/8" - 1/2" C 2.4 / 2400 Nl/Min v 6300 3/8" - 1/2" C 2.1 / 2100 Nl/Min v 6500 1/2" - 3/4" C 3.5 / 3500 Nl/Min v ISO 1 1/4" - 3/8" C 1.1 / 1100 Nl/Min v ISO 2 3/8" - 1/2" C 2.1 / 2100 Nl/Min v ISO 3 1/2" - 3/4" C 5.0 / 5000 Nl/Min v

MAC proportional pressure control PQE and pressure control system Series 6500
OPERATIONALBENEFITS 1. Accurate pressure control. 2. Fast response. 3. High flow. 4. Quick exhaust function. 5. Unaffected by change in line pressure. 6. Long life. 7. Designed to meet Nema 4 specifications. 8. Analog control. 9. Analog or TTL feedback. 10. Closed loop system. PPCTYPE Analog, single transducer external sense, bottom O-ring mount ELECTRICALDATA Reference PPC5Cspecifications PHYSICALDATA Connector :Reference PPC5Cspecifications Enclosure :Aluminum, sealed Mounting :Any plane Ambient temperature range :0 to 50C (32F to 120 PNEUMATICDATA Inlet pressure :120 PSI max Fluids :Air or inert gases Lubrication :Not required. However, if used, a medium aniline point oil is recommended Filtration :40 micron *Output pressure :20 to 100 PSI Overall accuracy :2.5% full scale All ports :1/2, 3/4, NPTF, BSPPL, BSPTR Flows : Output flow : 1/2± ports: Cv 5.33/4± ports: Cv 6 Exhaust flow : 1/2± ports: Cv 1.53/4± ports: Cv 1 **Output volume requirements :Port sizeOutput volume atMinimum length end of output pipeof output pipe 1/2±100 Cu. in. and larger78 50 to 99 Cu. in.100 3/4±100 Cu. in. and larger60 50 to 99 Cu. in.90 * The quick exhaust portion

MAC proportional pressure control PQE and pressure control system Series MPP
OPERATIONALBENEFITS 1. Fast response. applications. 2. Long life. 3. High flow. 4. The use of a digital command signal brings easy installation and use. 5. A compact and lightweight unit saves room and installation costs. 6. This system is the alternative to proportional valves if more than six pressures or closed loop feedback are not required. 7. The Multi-Pressure Pak is easy to set up and maintain. 8. For 2, 3 or 4 ported weld guns and other 9. Accuracy of 2.5 % of full scal TECHNICALDATA Min. supply pressure : 25 PSI (1.7 BAR) Max. supply pressure : 150 PSI (10 BAR) Pressure output range : 25-120 PSI (1.7 to 8 BAR) Voltages available    AC : 120/60, 110/50 DC : 12 & 24 volt. 1.8 to 12.7 watts Other AC and DC Consult factory voltages available : Air supply : 40 micron filtration Lubrication : Not required but if lubrication is used, a medium aniline point oil is recommended NOTE: Pressures shown are minimum and maximum safe working pressures. *Series Port size Flow 82 1/4" - 3/8" C 0.9 / 900 Nl/Min v 93 3/8" - 1/2" C 2.4 / 2400 Nl/Min v 6300 3/8" - 1/2" C 2.1 / 2100 Nl/Min v 6500 1/2" - 3/4" C 3.5 / 3500 Nl/Min

MAC proportional pressure control PQE and pressure control system Series PMPP
OPERATIONALBENEFITS 1. Fast response. 2. Long life. applications. 3. High flow. 4. The use of an analog or 4 bit or 8 bit command for other accuracies). signal brings increased accuracy in pressure 10. DeviceNet compatible. control. 5. A compact unit saves room and installation costs. 6. The analog and logic (TTL) outputs allow for constant pressure monitoring from the control unit. 7. Infinite or discrete number of pressures available. 8. For 2, 3 or 4 ported weld guns and other 9. Accuracy of 2.5 % of full scale (consult factor TECHNICALDATA Supply pressure : 2 to 10 bar/30 to 150 PSI *Output pressure : Standard : 1.7 to 10 bar, other ranges upon request. 25 to 150 PSI * For 82 and ISO 1 - 1.7 to 8 BAR, 25 to 120 PSI *Series Port size Flow 82 1/4" - 3/8" C 0.9 / 900 Nl/Min v 93 3/8" - 1/2" C 2.4 / 2400 Nl/Min v 6300 3/8" - 1/2" C 2.1 / 2100 Nl/Min v 6500 1/2" - 3/4" C 3.5 / 3500 Nl/Min v ISO 1 1/4" - 3/8" C 1.1 / 1100 Nl/Min v ISO 2 3/8" - 1/2" C 2.1 / 2100 Nl/Min v ISO 3 1/2" - 3/4" C 5.0 / 5000 Nl/Min v

MAC proportional pressure control PQE and pressure control system Series92
OPERATIONALBENEFITS 1. Accurate pressure control. 2. Fast response. 3. High flow. 4. Quick exhaust function. 5. Unaffected by change in line pressure. 6. Long life. 7. Designed to meet Nema 4 specifications. 8. Analog control. 9. Analog or TTL feedback. 10. Closed loop system. PPCTYPE Analog, single transducer external sense, bottom O-ring mount ELECTRICALDATA Reference PPC5Cspecifications PHYSICALDATA Connector :Reference PPC5Cspecifications Enclosure :Aluminum, sealed Mounting :Any plane Ambient temperature range :0 to 50C (32F to 120 PNEUMATICDATA Inlet pressure :120 PSI max Fluids :Air or inert gases Lubrication :Not required. However, if used, a medium aniline point oil is recommended Filtration :40 micron *Output pressure :20 to 100 PSI Overall accuracy :2.5% full scale All ports :1/4, 3/8, NPTF, BSPPL, BSPTR Flows :Output flow :1/4± ports: Cv 0.943/8± ports: Cv 1 Exhaust flow :1/4± ports: Cv 1.33/8± ports: Cv 1 **Output volume requirements :Port sizeOutput volume atMinimum length end of output pipeof output pipe 1/4±100 Cu. in. and larger12 50 to 99 Cu. in.50 3/8±100 Cu. in. and larger 24 50 to 99 Cu. in.50 * The quick exhaust portion of th

Export Company Export Company Export Company Global Trade Leads - Import & Export on our award-winning International Trade Site